Update Tags.py
This commit is contained in:
@@ -3,21 +3,21 @@ from dual_flowmeter import PLC_IP_ADDRESS
|
||||
|
||||
tags = [
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_daily_total","Pump_1_Daily_Flow_Rate_Total","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_run_status","Pump_1_Run_Status","BOOL", 1, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_flowrate","Pump_1_SCL_Flow_Meter","REAL", 250, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_run_status","Pump_1_Run_Status","BOOL", 0, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_flowrate","Pump_1_SCL_Flow_Meter","REAL", 250, 600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_yesterdays_total","Pump_1_Yesterdays_Total","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_power","Pump_1_Power","BOOL", 1, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_power","Pump_1_Power","BOOL", 0, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_prevmonth_total","Pump_1_PrevMonth_Total","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_month_total","Pump_1_Current_Month_Total","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_lifetime_total","Pump_1_Lifetime_Flow","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_suction","Suction_PSI_TP1_Scaled","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_daily_total","Pump_2_Daily_Flow_Rate_Total","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_run_status","Pump_2_Run_Status","BOOL", 1, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_flowrate","Pump_2_SCL_Flow_Meter","REAL", 250, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_run_status","Pump_2_Run_Status","BOOL", 0, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_flowrate","Pump_2_SCL_Flow_Meter","REAL", 250, 600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_yesterdays_total","Pump_2_Yesterdays_Total","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_power","Pump_2_Power","BOOL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_prevmonth_total","Pump_2_PrevMonth_Total","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_month_total","Pump_2_Current_Month_Total","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_power","Pump_2_Power","BOOL", 0, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_prevmonth_total","Pump_2_PrevMonth_Total","REAL", 100, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_month_total","Pump_2_Current_Month_Total","REAL", 50, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_lifetime_total","Pump_2_Lifetime_Flow","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_suction","Suction_PSI_TP2_Scaled","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_charge_psi_tp1", "Charge_PSI_TP1_Scaled", "REAL", 10, 3600, plc_type="Micro800")
|
||||
|
||||