1106
Pub_Sub/advvfdipp/thingsboard/v2/device_supervisor_advvfdippv2.cfg
Normal file
1106
Pub_Sub/advvfdipp/thingsboard/v2/device_supervisor_advvfdippv2.cfg
Normal file
File diff suppressed because one or more lines are too long
194
Pub_Sub/advvfdipp/thingsboard/v2/pub/sendData.py
Normal file
194
Pub_Sub/advvfdipp/thingsboard/v2/pub/sendData.py
Normal file
@@ -0,0 +1,194 @@
|
||||
# Enter your python code.
|
||||
import json
|
||||
from common.Logger import logger
|
||||
from quickfaas.remotebus import publish
|
||||
import re, uuid
|
||||
from paho.mqtt import client
|
||||
|
||||
|
||||
def sendData(message):
|
||||
#logger.debug(message)
|
||||
payload = {}
|
||||
for measure in message["measures"]:
|
||||
try:
|
||||
logger.debug(measure)
|
||||
if measure["name"] in ["wellstatus","pidcontrolmode","downholesensorstatus","alarmflowrate","alarmintakepressure","alarmintaketemperature","alarmtubingpressure","alarmvfd","alarmlockout","alarmfluidlevel","runpermissive","startpermissive","last_vfd_fault_code","vfd_fault", "flowmeter_fault"]:
|
||||
logger.debug("Converting DINT/BOOL to STRING")
|
||||
value = convert_int(measure["name"], measure["value"])
|
||||
logger.debug("Converted {} to {}".format(measure["value"], value))
|
||||
payload[measure["name"]] = value
|
||||
payload[measure["name"] + "_int"] = measure["value"]
|
||||
else:
|
||||
payload[measure["name"]] = measure["value"]
|
||||
except Exception as e:
|
||||
logger.error(e)
|
||||
|
||||
publish(__topic__, json.dumps(payload), __qos__)
|
||||
|
||||
def convert_int(plc_tag, value):
|
||||
well_status_codes = {
|
||||
0: "Running",
|
||||
1: "Pumped Off",
|
||||
2: "Alarmed",
|
||||
3: "Locked Out",
|
||||
4: "Stopped"
|
||||
}
|
||||
|
||||
pid_control_codes = {
|
||||
0: "Flow",
|
||||
1: "Fluid Level",
|
||||
2: "Tubing Pressure",
|
||||
3: "Manual"
|
||||
}
|
||||
|
||||
downhole_codes = {
|
||||
0: "OK",
|
||||
1: "Connecting",
|
||||
2: "Open Circuit",
|
||||
3: "Shorted",
|
||||
4: "Cannot Decode"
|
||||
}
|
||||
|
||||
permissive_codes = {
|
||||
0: "OK",
|
||||
1: "Flow",
|
||||
2: "Intake Pressure",
|
||||
3: "Intake Temperature",
|
||||
4: "Tubing Pressure",
|
||||
5: "VFD",
|
||||
6: "Fluid Level",
|
||||
7: "Min. Downtime"
|
||||
}
|
||||
|
||||
alarm_codes = {
|
||||
0: "OK",
|
||||
1: "Alarm"
|
||||
}
|
||||
|
||||
alarm_vfd_codes = {
|
||||
0: "OK",
|
||||
1: "Locked Out"
|
||||
}
|
||||
|
||||
vfd_fault_codes = {
|
||||
0: "No Fault",
|
||||
2: "Auxiliary Input",
|
||||
3: "Power Loss",
|
||||
4: "UnderVoltage",
|
||||
5: "OverVoltage",
|
||||
7: "Motor Overload",
|
||||
8: "Heatsink OverTemp",
|
||||
9: "Thermister OverTemp",
|
||||
10: "Dynamic Brake OverTemp",
|
||||
12: "Hardware OverCurrent",
|
||||
13: "Ground Fault",
|
||||
14: "Ground Warning",
|
||||
15: "Load Loss",
|
||||
17: "Input Phase Loss",
|
||||
18: "Motor PTC Trip",
|
||||
19: "Task Overrun",
|
||||
20: "Torque Prove Speed Band",
|
||||
21: "Output Phase Loss",
|
||||
24: "Decel Inhibit",
|
||||
25: "OverSpeed Limit",
|
||||
26: "Brake Slipped",
|
||||
27: "Torque Prove Conflict",
|
||||
28: "TP Encls Confict",
|
||||
29: "Analog In Loss",
|
||||
33: "Auto Restarts Exhausted",
|
||||
35: "IPM OverCurrent",
|
||||
36: "SW OverCurrent",
|
||||
38: "Phase U to Ground",
|
||||
39: "Phase V to Ground",
|
||||
40: "Phase W to Ground",
|
||||
41: "Phase UV Short",
|
||||
42: "Phase VW Short",
|
||||
43: "Phase WU Short",
|
||||
44: "Phase UNeg to Ground",
|
||||
45: "Phase VNeg to Ground",
|
||||
46: "Phase WNeg to Ground",
|
||||
48: "System Defaulted",
|
||||
49: "Drive Powerup",
|
||||
51: "Clear Fault Queue",
|
||||
55: "Control Board Overtemp",
|
||||
59: "Invalid Code",
|
||||
61: "Shear Pin 1",
|
||||
62: "Shear Pin 2",
|
||||
64: "Drive Overload",
|
||||
66: "OW Torque Level",
|
||||
67: "Pump Off",
|
||||
71: "Port 1 Adapter",
|
||||
72: "Port 2 Adapter",
|
||||
73: "Port 3 Adapter",
|
||||
74: "Port 4 Adapter",
|
||||
75: "Port 5 Adapter",
|
||||
76: "Port 6 Adapter",
|
||||
77: "IR Volts Range",
|
||||
78: "FluxAmps Ref Range",
|
||||
79: "Excessive Load",
|
||||
80: "AutoTune Aborted",
|
||||
81: "Port 1 DPI Loss",
|
||||
82: "Port 2 DPI Loss",
|
||||
83: "Port 3 DPI Loss",
|
||||
84: "Port 4 DPI Loss",
|
||||
85: "Port 5 DPI Loss",
|
||||
86: "Port 6 DPI Loss",
|
||||
87: "IXo Voltage Range",
|
||||
91: "Primary Velocity Feedback Loss",
|
||||
93: "Hardware Enable Check",
|
||||
94: "Alternate Velocity Feedback Loss",
|
||||
95: "Auxiliary Velocity Feedback Loss",
|
||||
96: "Position Feedback Loss",
|
||||
97: "Auto Tach Switch",
|
||||
100: "Parameter Checksum",
|
||||
101: "Power Down NVS Blank",
|
||||
102: "NVS Not Blank",
|
||||
103: "Power Down NVS Incompatible",
|
||||
104: "Power Board Checksum",
|
||||
106: "Incompat MCB-PB",
|
||||
107: "Replaced MCB-PB",
|
||||
108: "Analog Calibration Checksum",
|
||||
110: "Invalid Power Board Data",
|
||||
111: "Power Board Invalid ID",
|
||||
112: "Power Board App Min Version",
|
||||
113: "Tracking DataError",
|
||||
115: "Power Down Table Full",
|
||||
116: "Power Down Entry Too Large",
|
||||
117: "Power Down Data Checksum",
|
||||
118: "Power Board Power Down Checksum",
|
||||
124: "App ID Changed",
|
||||
125: "Using Backup App",
|
||||
134: "Start on Power Up",
|
||||
137: "External Precharge Error",
|
||||
138: "Precharge Open",
|
||||
141: "Autotune Enc Angle",
|
||||
142: "Autotune Speed Restricted",
|
||||
143: "Autotune Current Regulator",
|
||||
144: "Autotune Inertia",
|
||||
145: "Autotune Travel",
|
||||
13035: "Net IO Timeout",
|
||||
13037: "Net IO Timeout"
|
||||
|
||||
}
|
||||
|
||||
plc_tags = {
|
||||
"wellstatus": well_status_codes.get(value, "Invalid Code"),
|
||||
"pidcontrolmode": pid_control_codes.get(value, "Invalid Code"),
|
||||
"downholesensorstatus": downhole_codes.get(value, "Invalid Code"),
|
||||
"alarmflowrate": alarm_codes.get(value, "Invalid Code"),
|
||||
"alarmintakepressure": alarm_codes.get(value, "Invalid Code"),
|
||||
"alarmintaketemperature": alarm_codes.get(value, "Invalid Code"),
|
||||
"alarmtubingpressure": alarm_codes.get(value, "Invalid Code"),
|
||||
"alarmvfd": alarm_codes.get(value, "Invalid Code"),
|
||||
"alarmlockout": alarm_vfd_codes.get(value, "Invalid Code"),
|
||||
"alarmfluidlevel": alarm_codes.get(value, "Invalid Code"),
|
||||
"runpermissive": permissive_codes.get(value, "Invalid Code"),
|
||||
"startpermissive": permissive_codes.get(value, "Invalid Code"),
|
||||
"last_vfd_fault_code": vfd_fault_codes.get(value, "Invalid Code"),
|
||||
"vfd_fault": vfd_fault_codes.get(value, "Invalid Code"),
|
||||
"flowmeter_fault": alarm_codes.get(value, "Invalid Code")
|
||||
}
|
||||
|
||||
return plc_tags.get(plc_tag, "Invalid Tag")
|
||||
|
||||
|
||||
258
Pub_Sub/advvfdipp/thingsboard/v2/sub/receiveCommand.py
Normal file
258
Pub_Sub/advvfdipp/thingsboard/v2/sub/receiveCommand.py
Normal file
@@ -0,0 +1,258 @@
|
||||
# Enter your python code.
|
||||
import json
|
||||
import time
|
||||
from quickfaas.measure import recall
|
||||
from common.Logger import logger
|
||||
|
||||
def sync(wizard_api):
|
||||
#get new values and send
|
||||
payload = {}
|
||||
topic = "v1/devices/me/telemetry"
|
||||
try:
|
||||
data = recall()#json.loads(recall().decode("utf-8"))
|
||||
except Exception as e:
|
||||
logger.error(e)
|
||||
logger.info(data)
|
||||
for controller in data:
|
||||
for measure in controller["measures"]:
|
||||
#publish measure
|
||||
if measure["name"] in ["wellstatus","pidcontrolmode","downholesensorstatus","alarmflowrate","alarmintakepressure","alarmintaketemperature","alarmtubingpressure","alarmvfd","alarmlockout","alarmfluidlevel","runpermissive","startpermissive","last_vfd_fault_code","vfd_fault", "flowmeter_fault"]:
|
||||
payload[measure["name"]] = convert_int(measure["name"], measure["value"])
|
||||
payload[measure["name"]+ "_int"] = measure["value"]
|
||||
else:
|
||||
payload[measure["name"]] = measure["value"]
|
||||
logger.debug("Sending on topic: {}".format(topic))
|
||||
logger.debug("Sending value: {}".format(payload))
|
||||
wizard_api.mqtt_publish(topic, json.dumps(payload))
|
||||
def writeplctag(value, wizard_api):
|
||||
try:
|
||||
#value = json.loads(value.replace("'",'"'))
|
||||
logger.debug(value)
|
||||
message = {"advvfdipp":{value["measurement"]: value["value"]}}
|
||||
resp = wizard_api.write_plc_values(message)
|
||||
#logger.debug("RETURN FROM WRITE: {}".format(resp))
|
||||
return True
|
||||
except Exception as e:
|
||||
logger.debug(e)
|
||||
return False
|
||||
|
||||
def receiveCommand(topic, payload, wizard_api):
|
||||
try:
|
||||
logger.debug(topic)
|
||||
logger.debug(json.loads(payload))
|
||||
p = json.loads(payload)
|
||||
command = p["method"]
|
||||
commands = {
|
||||
"sync": sync,
|
||||
"writeplctag": writeplctag,
|
||||
}
|
||||
if command == "setPLCTag":
|
||||
result = commands["writeplctag"](p["params"],wizard_api)
|
||||
elif command == "changeSetpoint":
|
||||
try:
|
||||
params_type = {"measurement": "pidcontrolmode", "value": p["params"]["setpointType"]}
|
||||
if params_type["value"]:
|
||||
commands["writeplctag"](params_type, wizard_api)
|
||||
time.sleep(2)
|
||||
except:
|
||||
pass
|
||||
try:
|
||||
modes = {0: "flowsetpoint", 1: "fluidlevelsetpoint", 2: "tubingpressuresetpoint", 3: "manualfrequencysetpoint"}
|
||||
params_value = {"value": p["params"]["setpointValue"]}
|
||||
if params_value["value"]:
|
||||
params_value["measurement"] = modes[getMode()]
|
||||
commands["writeplctag"](params_value, wizard_api)
|
||||
except Exception as e:
|
||||
logger.debug("DID NOT WRITE SETPOINT")
|
||||
logger.debug(e)
|
||||
|
||||
#logger.debug(command)
|
||||
ack(topic.split("/")[-1], wizard_api)
|
||||
time.sleep(5)
|
||||
sync(wizard_api)
|
||||
except Exception as e:
|
||||
logger.debug(e)
|
||||
|
||||
|
||||
def ack(msgid, wizard_api):
|
||||
#logger.debug(msgid)
|
||||
#logger.debug(mac)
|
||||
#logger.debug(name)
|
||||
#logger.debug(value)
|
||||
wizard_api.mqtt_publish("v1/devices/me/rpc/response/" + str(msgid), json.dumps({"msg": {"time": time.time()}, "metadata": "", "msgType": ""}))
|
||||
|
||||
def getMode():
|
||||
try:
|
||||
data = recall()
|
||||
for controller in data:
|
||||
for measure in controller["measures"]:
|
||||
if measure["name"] == "pidcontrolmode":
|
||||
return measure["value"]
|
||||
except:
|
||||
return None
|
||||
|
||||
def convert_int(plc_tag, value):
|
||||
well_status_codes = {
|
||||
0: "Running",
|
||||
1: "Pumped Off",
|
||||
2: "Alarmed",
|
||||
3: "Locked Out",
|
||||
4: "Stopped"
|
||||
}
|
||||
|
||||
pid_control_codes = {
|
||||
0: "Flow",
|
||||
1: "Fluid Level",
|
||||
2: "Tubing Pressure",
|
||||
3: "Manual"
|
||||
}
|
||||
|
||||
downhole_codes = {
|
||||
0: "OK",
|
||||
1: "Connecting",
|
||||
2: "Open Circuit",
|
||||
3: "Shorted",
|
||||
4: "Cannot Decode"
|
||||
}
|
||||
|
||||
permissive_codes = {
|
||||
0: "OK",
|
||||
1: "Flow",
|
||||
2: "Intake Pressure",
|
||||
3: "Intake Temperature",
|
||||
4: "Tubing Pressure",
|
||||
5: "VFD",
|
||||
6: "Fluid Level",
|
||||
7: "Min. Downtime"
|
||||
}
|
||||
|
||||
alarm_codes = {
|
||||
0: "OK",
|
||||
1: "Alarm"
|
||||
}
|
||||
|
||||
alarm_vfd_codes = {
|
||||
0: "OK",
|
||||
1: "Locked Out"
|
||||
}
|
||||
|
||||
vfd_fault_codes = {
|
||||
0: "No Fault",
|
||||
2: "Auxiliary Input",
|
||||
3: "Power Loss",
|
||||
4: "UnderVoltage",
|
||||
5: "OverVoltage",
|
||||
7: "Motor Overload",
|
||||
8: "Heatsink OverTemp",
|
||||
9: "Thermister OverTemp",
|
||||
10: "Dynamic Brake OverTemp",
|
||||
12: "Hardware OverCurrent",
|
||||
13: "Ground Fault",
|
||||
14: "Ground Warning",
|
||||
15: "Load Loss",
|
||||
17: "Input Phase Loss",
|
||||
18: "Motor PTC Trip",
|
||||
19: "Task Overrun",
|
||||
20: "Torque Prove Speed Band",
|
||||
21: "Output Phase Loss",
|
||||
24: "Decel Inhibit",
|
||||
25: "OverSpeed Limit",
|
||||
26: "Brake Slipped",
|
||||
27: "Torque Prove Conflict",
|
||||
28: "TP Encls Confict",
|
||||
29: "Analog In Loss",
|
||||
33: "Auto Restarts Exhausted",
|
||||
35: "IPM OverCurrent",
|
||||
36: "SW OverCurrent",
|
||||
38: "Phase U to Ground",
|
||||
39: "Phase V to Ground",
|
||||
40: "Phase W to Ground",
|
||||
41: "Phase UV Short",
|
||||
42: "Phase VW Short",
|
||||
43: "Phase WU Short",
|
||||
44: "Phase UNeg to Ground",
|
||||
45: "Phase VNeg to Ground",
|
||||
46: "Phase WNeg to Ground",
|
||||
48: "System Defaulted",
|
||||
49: "Drive Powerup",
|
||||
51: "Clear Fault Queue",
|
||||
55: "Control Board Overtemp",
|
||||
59: "Invalid Code",
|
||||
61: "Shear Pin 1",
|
||||
62: "Shear Pin 2",
|
||||
64: "Drive Overload",
|
||||
66: "OW Torque Level",
|
||||
67: "Pump Off",
|
||||
71: "Port 1 Adapter",
|
||||
72: "Port 2 Adapter",
|
||||
73: "Port 3 Adapter",
|
||||
74: "Port 4 Adapter",
|
||||
75: "Port 5 Adapter",
|
||||
76: "Port 6 Adapter",
|
||||
77: "IR Volts Range",
|
||||
78: "FluxAmps Ref Range",
|
||||
79: "Excessive Load",
|
||||
80: "AutoTune Aborted",
|
||||
81: "Port 1 DPI Loss",
|
||||
82: "Port 2 DPI Loss",
|
||||
83: "Port 3 DPI Loss",
|
||||
84: "Port 4 DPI Loss",
|
||||
85: "Port 5 DPI Loss",
|
||||
86: "Port 6 DPI Loss",
|
||||
87: "IXo Voltage Range",
|
||||
91: "Primary Velocity Feedback Loss",
|
||||
93: "Hardware Enable Check",
|
||||
94: "Alternate Velocity Feedback Loss",
|
||||
95: "Auxiliary Velocity Feedback Loss",
|
||||
96: "Position Feedback Loss",
|
||||
97: "Auto Tach Switch",
|
||||
100: "Parameter Checksum",
|
||||
101: "Power Down NVS Blank",
|
||||
102: "NVS Not Blank",
|
||||
103: "Power Down NVS Incompatible",
|
||||
104: "Power Board Checksum",
|
||||
106: "Incompat MCB-PB",
|
||||
107: "Replaced MCB-PB",
|
||||
108: "Analog Calibration Checksum",
|
||||
110: "Invalid Power Board Data",
|
||||
111: "Power Board Invalid ID",
|
||||
112: "Power Board App Min Version",
|
||||
113: "Tracking DataError",
|
||||
115: "Power Down Table Full",
|
||||
116: "Power Down Entry Too Large",
|
||||
117: "Power Down Data Checksum",
|
||||
118: "Power Board Power Down Checksum",
|
||||
124: "App ID Changed",
|
||||
125: "Using Backup App",
|
||||
134: "Start on Power Up",
|
||||
137: "External Precharge Error",
|
||||
138: "Precharge Open",
|
||||
141: "Autotune Enc Angle",
|
||||
142: "Autotune Speed Restricted",
|
||||
143: "Autotune Current Regulator",
|
||||
144: "Autotune Inertia",
|
||||
145: "Autotune Travel",
|
||||
13035: "Net IO Timeout",
|
||||
13037: "Net IO Timeout"
|
||||
|
||||
}
|
||||
|
||||
plc_tags = {
|
||||
"wellstatus": well_status_codes.get(value, "Invalid Code"),
|
||||
"pidcontrolmode": pid_control_codes.get(value, "Invalid Code"),
|
||||
"downholesensorstatus": downhole_codes.get(value, "Invalid Code"),
|
||||
"alarmflowrate": alarm_codes.get(value, "Invalid Code"),
|
||||
"alarmintakepressure": alarm_codes.get(value, "Invalid Code"),
|
||||
"alarmintaketemperature": alarm_codes.get(value, "Invalid Code"),
|
||||
"alarmtubingpressure": alarm_codes.get(value, "Invalid Code"),
|
||||
"alarmvfd": alarm_codes.get(value, "Invalid Code"),
|
||||
"alarmlockout": alarm_vfd_codes.get(value, "Invalid Code"),
|
||||
"alarmfluidlevel": alarm_codes.get(value, "Invalid Code"),
|
||||
"runpermissive": permissive_codes.get(value, "Invalid Code"),
|
||||
"startpermissive": permissive_codes.get(value, "Invalid Code"),
|
||||
"last_vfd_fault_code": vfd_fault_codes.get(value, "Invalid Code"),
|
||||
"vfd_fault": vfd_fault_codes.get(value, "Invalid Code"),
|
||||
"flowmeter_fault": alarm_codes.get(value, "Invalid Code")
|
||||
}
|
||||
|
||||
return plc_tags.get(plc_tag, "Invalid Tag")
|
||||
@@ -32,9 +32,9 @@ def write_config(path, config, pub, sub):
|
||||
root = os.getcwd()
|
||||
devicetype = "advvfdipp"
|
||||
startversion = 1
|
||||
deviceconfig = "device_supervisor_" + devicetype +"v" + str(startversion) + ".cfg"
|
||||
deviceconfig = "device_supervisor_" + devicetype + "_tb_" +"v" + str(startversion) + ".cfg"
|
||||
|
||||
#write_code(root + "/" + devicetype + "/v" + str(startversion) + "/pub" + "/sendData.py", get_config_pub(root + "/" + devicetype + "/v" + str(startversion) + "/" + deviceconfig))
|
||||
#write_code(root + "/" + devicetype + "/v" + str(startversion) + "/sub" + "/receiveCommand.py", get_config_sub(root + "/" + devicetype + "/v" + str(startversion) + "/" + deviceconfig))
|
||||
|
||||
write_config(root + "/" + devicetype + "/guidon/v" + str(startversion + 1) + "/device_supervisor_" + devicetype + "v" + str(startversion + 1) + ".cfg", get_config(root + "/" + devicetype + "/guidon/v" + str(startversion) + "/device_supervisor_" + devicetype + "v" + str(startversion) + ".cfg"), code_to_string(root + "/" + devicetype + "/guidon/v" + str(startversion + 1) + "/pub" + "/sendData.py"), code_to_string(root + "/" + devicetype + "/guidon/v" + str(startversion + 1) + "/sub" + "/receiveCommand.py"))
|
||||
write_config(root + "/" + devicetype + "/thingsboard/v" + str(startversion + 1) + "/device_supervisor_" + devicetype + "v" + str(startversion + 1) + ".cfg", get_config(root + "/" + devicetype + "/thingsboard/v" + str(startversion) + "/device_supervisor_" + devicetype + "_tb_v" + str(startversion) + ".cfg"), code_to_string(root + "/" + devicetype + "/thingsboard/v" + str(startversion + 1) + "/pub" + "/sendData.py"), code_to_string(root + "/" + devicetype + "/thingsboard/v" + str(startversion + 1) + "/sub" + "/receiveCommand.py"))
|
||||
148
Pub_Sub/flowmeterskid/flowmeter.py
Normal file
148
Pub_Sub/flowmeterskid/flowmeter.py
Normal file
@@ -0,0 +1,148 @@
|
||||
# Enter your python code.
|
||||
import json
|
||||
from datetime import datetime as dt
|
||||
from common.Logger import logger
|
||||
from quickfaas.remotebus import publish
|
||||
from mobiuspi_lib.gps import GPS
|
||||
|
||||
payload = {}
|
||||
|
||||
try:
|
||||
with open("/var/user/files/totalizers.json", "r") as t:
|
||||
totalizers = json.load(t)
|
||||
if not totalizers:
|
||||
logger.info("-----INITIALIZING TOTALIZERS-----")
|
||||
totalizers = {
|
||||
"day": 0,
|
||||
"week": 0,
|
||||
"month": 0,
|
||||
"year": 0,
|
||||
"lifetime": 0,
|
||||
"dayHolding": 0,
|
||||
"weekHolding": 0,
|
||||
"monthHolding": 0,
|
||||
"yearHolding": 0
|
||||
}
|
||||
except:
|
||||
totalizers = {
|
||||
"day": 0,
|
||||
"week": 0,
|
||||
"month": 0,
|
||||
"year": 0,
|
||||
"lifetime": 0,
|
||||
"dayHolding": 0,
|
||||
"weekHolding": 0,
|
||||
"monthHolding": 0,
|
||||
"yearHolding": 0
|
||||
}
|
||||
|
||||
|
||||
|
||||
|
||||
def sendData(message,wizard_api):
|
||||
logger.debug(message)
|
||||
payload = {"ts": (round(dt.timestamp(dt.now())/600)*600)*1000, "values": {}}
|
||||
resetPayload = {"ts": "", "values": {}}
|
||||
for measure in message["values"]["flowmeter"].keys():
|
||||
try:
|
||||
if measure in ["totalizer_1"]:
|
||||
payload["values"]["day_volume"], dayReset = totalizeDay(message["values"]["flowmeter"][measure]["raw_data"])
|
||||
payload["values"]["week_volume"], weekReset = totalizeWeek(message["values"]["flowmeter"][measure]["raw_data"])
|
||||
payload["values"]["month_volume"], monthReset = totalizeMonth(message["values"]["flowmeter"][measure]["raw_data"])
|
||||
payload["values"]["year_volume"], yearReset = totalizeYear(message["values"]["flowmeter"][measure]["raw_data"])
|
||||
payload["values"][measure] = message["values"]["flowmeter"][measure]["raw_data"]
|
||||
except Exception as e:
|
||||
logger.error(e)
|
||||
try:
|
||||
payload["values"]["latitude"], payload["values"]["longitude"], payload["values"]["speed"] = getGPS()
|
||||
except:
|
||||
logger.error("Could not get GPS coordinates")
|
||||
publish(__topic__, json.dumps(payload), __qos__)
|
||||
|
||||
if dayReset:
|
||||
resetPayload["values"]["day_volume"] = 0
|
||||
if weekReset:
|
||||
resetPayload["values"]["week_volume"] = 0
|
||||
if monthReset:
|
||||
resetPayload["values"]["month_volume"] = 0
|
||||
if yearReset:
|
||||
resetPayload["values"]["year_volume"] = 0
|
||||
|
||||
if resetPayload["values"]:
|
||||
resetPayload["ts"] = 1 + (round(dt.timestamp(dt.now())/600)*600)*1000
|
||||
publish(__topic__, json.dumps(resetPayload), __qos__)
|
||||
|
||||
def saveTotalizers():
|
||||
try:
|
||||
with open("/var/user/files/totalizers.json", "w") as t:
|
||||
json.dump(totalizers,t)
|
||||
except Exception as e:
|
||||
logger.error(e)
|
||||
|
||||
def getGPS():
|
||||
# Create a gps instance
|
||||
gps = GPS()
|
||||
|
||||
# Retrieve GPS information
|
||||
position_status = gps.get_position_status()
|
||||
logger.debug("position_status: ")
|
||||
logger.debug(position_status)
|
||||
latitude = position_status["latitude"].split(" ")
|
||||
longitude = position_status["longitude"].split(" ")
|
||||
lat_dec = int(latitude[0][:-1]) + (float(latitude[1][:-1])/60)
|
||||
lon_dec = int(longitude[0][:-1]) + (float(longitude[1][:-1])/60)
|
||||
if latitude[2] == "S":
|
||||
lat_dec = lat_dec * -1
|
||||
if longitude[2] == "W":
|
||||
lon_dec = lon_dec * -1
|
||||
#lat_dec = round(lat_dec, 7)
|
||||
#lon_dec = round(lon_dec, 7)
|
||||
logger.info("HERE IS THE GPS COORDS")
|
||||
logger.info(f"LATITUDE: {lat_dec}, LONGITUDE: {lon_dec}")
|
||||
speedKnots = position_status["speed"].split(" ")
|
||||
speedMPH = float(speedKnots[0]) * 1.151
|
||||
return (f"{lat_dec:.8f}",f"{lon_dec:.8f}",f"{speedMPH:.2f}")
|
||||
|
||||
def totalizeDay(lifetime):
|
||||
now = dt.fromtimestamp(round(dt.timestamp(dt.now())/600)*600)
|
||||
reset = False
|
||||
value = lifetime - totalizers["dayHolding"]
|
||||
if not int(now.strftime("%d")) == int(totalizers["day"]):
|
||||
totalizers["dayHolding"] = lifetime
|
||||
totalizers["day"] = int(now.strftime("%d"))
|
||||
saveTotalizers()
|
||||
reset = True
|
||||
return (value,reset)
|
||||
|
||||
def totalizeWeek(lifetime):
|
||||
now = dt.fromtimestamp(round(dt.timestamp(dt.now())/600)*600)
|
||||
reset = False
|
||||
value = lifetime - totalizers["weekHolding"]
|
||||
if not now.strftime("%U") == totalizers["week"] and now.strftime("%a") == "Sun":
|
||||
totalizers["weekHolding"] = lifetime
|
||||
totalizers["week"] = now.strftime("%U")
|
||||
saveTotalizers()
|
||||
reset = True
|
||||
return (value, reset)
|
||||
|
||||
def totalizeMonth(lifetime):
|
||||
now = dt.fromtimestamp(round(dt.timestamp(dt.now())/600)*600)
|
||||
reset = False
|
||||
value = lifetime - totalizers["monthHolding"]
|
||||
if not int(now.strftime("%m")) == int(totalizers["month"]):
|
||||
totalizers["monthHolding"] = lifetime
|
||||
totalizers["month"] = now.strftime("%m")
|
||||
saveTotalizers()
|
||||
reset = True
|
||||
return (value,reset)
|
||||
|
||||
def totalizeYear(lifetime):
|
||||
now = dt.fromtimestamp(round(dt.timestamp(dt.now())/600)*600)
|
||||
reset = False
|
||||
value = lifetime - totalizers["yearHolding"]
|
||||
if not int(now.strftime("%Y")) == int(totalizers["year"]):
|
||||
totalizers["yearHolding"] = lifetime
|
||||
totalizers["year"] = now.strftime("%Y")
|
||||
saveTotalizers()
|
||||
reset = True
|
||||
return (value, reset)
|
||||