Auto-Setup Files

Changed project name to IPP, added files to automatically configure PLC
This commit is contained in:
Patrick McDonagh
2016-09-15 12:23:01 -05:00
parent 9a8729a70a
commit 01967b1727
143 changed files with 1607 additions and 1532 deletions

View File

@@ -1 +1 @@
TO RELINK
COMPILED

View File

@@ -1,4 +1,4 @@
<?xml version="1.0" encoding="utf-8"?>
<DevicePreferences xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema">
<Micro800ConnectionPath>DESKTOP-AGBV11S!Old_Parkland\10.20.158.3</Micro800ConnectionPath>
<Micro800ConnectionPath>PMCDONAGH-SURF!AB_ETHIP-1\192.168.1.5</Micro800ConnectionPath>
</DevicePreferences>

View File

@@ -8,7 +8,7 @@
<DLGRCP_VarVA>
<DLGRCP_VarVA>
<ArrayLength>1</ArrayLength>
<VirtualAddress>1380</VirtualAddress>
<VirtualAddress>1372</VirtualAddress>
<Name>DH_IntakeTemperature</Name>
<Index>1</Index>
<ISaDataType>REAL</ISaDataType>
@@ -18,7 +18,7 @@
</DLGRCP_VarVA>
<DLGRCP_VarVA>
<ArrayLength>1</ArrayLength>
<VirtualAddress>1384</VirtualAddress>
<VirtualAddress>1376</VirtualAddress>
<Name>DH_IntakePressure</Name>
<Index>2</Index>
<ISaDataType>REAL</ISaDataType>
@@ -28,7 +28,7 @@
</DLGRCP_VarVA>
<DLGRCP_VarVA>
<ArrayLength>1</ArrayLength>
<VirtualAddress>2213</VirtualAddress>
<VirtualAddress>2209</VirtualAddress>
<Name>DH_DownholeStatus</Name>
<Index>3</Index>
<ISaDataType>STRING</ISaDataType>

View File

@@ -45,8 +45,6 @@ Controller.Micro820.Micro820._IO_EM_DO_05 FALSE
Controller.Micro820.Micro820._IO_EM_DO_06 FALSE
Controller.Micro820.Micro820._IO_P1_AI_00
Controller.Micro820.Micro820._IO_P1_AI_01
Controller.Micro820.Micro820._IO_P1_AI_02
Controller.Micro820.Micro820._IO_P1_AI_03
Controller.Micro820.Micro820.alarm_DHPressure
Controller.Micro820.Micro820.alarm_DHTemperature
Controller.Micro820.Micro820.alarm_E300
1 Controller.Micro820.Micro820.__SYSVA_ABORT_CYCLE FALSE
45 Controller.Micro820.Micro820._IO_EM_DO_06 FALSE
46 Controller.Micro820.Micro820._IO_P1_AI_00
47 Controller.Micro820.Micro820._IO_P1_AI_01
Controller.Micro820.Micro820._IO_P1_AI_02
Controller.Micro820.Micro820._IO_P1_AI_03
48 Controller.Micro820.Micro820.alarm_DHPressure
49 Controller.Micro820.Micro820.alarm_DHTemperature
50 Controller.Micro820.Micro820.alarm_E300

View File

@@ -1,473 +1,473 @@
<modbusServer Version="2.0">
<modbusRegister name="DISCRETES_INPUTS">
<mapping variable="Auto_Mode" parent="Micro820" dataType="Bool" address="100001" va="0x478">
<mapping variable="Auto_Mode" parent="Micro820" dataType="Bool" address="100001" va="0x470">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="Test_Mode" parent="Micro820" dataType="Bool" address="100002" va="0x482">
<mapping variable="Test_Mode" parent="Micro820" dataType="Bool" address="100002" va="0x47a">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="Hand_Mode" parent="Micro820" dataType="Bool" address="100003" va="0x477">
<mapping variable="Hand_Mode" parent="Micro820" dataType="Bool" address="100003" va="0x46f">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="Contactor_Status" parent="Micro820" dataType="Bool" address="100004" va="0x47a">
<mapping variable="Contactor_Status" parent="Micro820" dataType="Bool" address="100004" va="0x472">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="Start_Permissive" parent="Micro820" dataType="Bool" address="100005" va="0x46c">
<mapping variable="Start_Permissive" parent="Micro820" dataType="Bool" address="100005" va="0x464">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="Run_Permissive" parent="Micro820" dataType="Bool" address="100006" va="0x46d">
<mapping variable="Run_Permissive" parent="Micro820" dataType="Bool" address="100006" va="0x465">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_READ" parent="Micro820" dataType="Bool" address="100007" va="0x47b">
<mapping variable="cfg_READ" parent="Micro820" dataType="Bool" address="100007" va="0x473">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_WRITE" parent="Micro820" dataType="Bool" address="100009" va="0x47c">
<mapping variable="cfg_WRITE" parent="Micro820" dataType="Bool" address="100009" va="0x474">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="TripStatus" parent="Micro820" dataType="Bool" address="100010" va="0x480">
<mapping variable="TripStatus" parent="Micro820" dataType="Bool" address="100010" va="0x478">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="WarningStatus" parent="Micro820" dataType="Bool" address="100011" va="0x481">
<mapping variable="WarningStatus" parent="Micro820" dataType="Bool" address="100011" va="0x479">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="OverloadTrip" parent="Micro820" dataType="Bool" address="100012" va="0x47f">
<mapping variable="OverloadTrip" parent="Micro820" dataType="Bool" address="100012" va="0x477">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="VoltageOK" parent="Micro820" dataType="Bool" address="100013" va="0x483">
<mapping variable="VoltageOK" parent="Micro820" dataType="Bool" address="100013" va="0x47b">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="TripResetCmd" parent="Micro820" dataType="Bool" address="100014" va="0x47e">
<mapping variable="TripResetCmd" parent="Micro820" dataType="Bool" address="100014" va="0x476">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="DigitalInput_Status_0" parent="Micro820" dataType="Bool" address="100015" va="0x466">
<mapping variable="DigitalInput_Status_0" parent="Micro820" dataType="Bool" address="100015" va="0x45e">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="DigitalInput_Status_1" parent="Micro820" dataType="Bool" address="100016" va="0x467">
<mapping variable="DigitalInput_Status_1" parent="Micro820" dataType="Bool" address="100016" va="0x45f">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="DigitalInput_Status_2" parent="Micro820" dataType="Bool" address="100017" va="0x468">
<mapping variable="DigitalInput_Status_2" parent="Micro820" dataType="Bool" address="100017" va="0x460">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="DigitalInput_Status_3" parent="Micro820" dataType="Bool" address="100018" va="0x469">
<mapping variable="DigitalInput_Status_3" parent="Micro820" dataType="Bool" address="100018" va="0x461">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="DigitalInput_Status_4" parent="Micro820" dataType="Bool" address="100019" va="0x470">
<mapping variable="DigitalInput_Status_4" parent="Micro820" dataType="Bool" address="100019" va="0x468">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="DigitalInput_Status_5" parent="Micro820" dataType="Bool" address="100020" va="0x46f">
<mapping variable="DigitalInput_Status_5" parent="Micro820" dataType="Bool" address="100020" va="0x467">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="Temp_Shutdown_Enabled" parent="Micro820" dataType="Bool" address="100021" va="0x471">
<mapping variable="Temp_Shutdown_Enabled" parent="Micro820" dataType="Bool" address="100021" va="0x469">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="Pressure_Shutdown_Enabled" parent="Micro820" dataType="Bool" address="100022" va="0x473">
<mapping variable="Pressure_Shutdown_Enabled" parent="Micro820" dataType="Bool" address="100022" va="0x46b">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="Temp_Startup_Enabled" parent="Micro820" dataType="Bool" address="100023" va="0x472">
<mapping variable="Temp_Startup_Enabled" parent="Micro820" dataType="Bool" address="100023" va="0x46a">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="Pressure_Startup_Enabled" parent="Micro820" dataType="Bool" address="100024" va="0x474">
<mapping variable="Pressure_Startup_Enabled" parent="Micro820" dataType="Bool" address="100024" va="0x46c">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="Start_Command" parent="Micro820" dataType="Bool" address="100025" va="0x46a">
<mapping variable="Start_Command" parent="Micro820" dataType="Bool" address="100025" va="0x462">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="Stop_Command" parent="Micro820" dataType="Bool" address="100026" va="0x46b">
<mapping variable="Stop_Command" parent="Micro820" dataType="Bool" address="100026" va="0x463">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="Pressure_Switch_Enabled" parent="Micro820" dataType="Bool" address="100027" va="0x4a4">
<mapping variable="Pressure_Switch_Enabled" parent="Micro820" dataType="Bool" address="100027" va="0x49c">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="Downhole_Tool_Enabled" parent="Micro820" dataType="Bool" address="100028" va="0x4a5">
<mapping variable="Downhole_Tool_Enabled" parent="Micro820" dataType="Bool" address="100028" va="0x49d">
<MBVarInfo ElemType="Bool" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_GF_GroundFaultInhibitTime" parent="Micro820" dataType="USInt" address="100056" va="0x4d3">
<mapping variable="cfg_GF_GroundFaultInhibitTime" parent="Micro820" dataType="USInt" address="100056" va="0x4cb">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_CurrentImbalanceInhibitTime" parent="Micro820" dataType="USInt" address="100064" va="0x4da">
<mapping variable="cfg_I_CurrentImbalanceInhibitTime" parent="Micro820" dataType="USInt" address="100064" va="0x4d2">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_CurrentImbalanceInhibitTime" parent="Micro820" dataType="USInt" address="100072" va="0x4da">
<mapping variable="cfg_I_CurrentImbalanceInhibitTime" parent="Micro820" dataType="USInt" address="100072" va="0x4d2">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_CurrentImbalanceTripDelay" parent="Micro820" dataType="USInt" address="100080" va="0x4db">
<mapping variable="cfg_I_CurrentImbalanceTripDelay" parent="Micro820" dataType="USInt" address="100080" va="0x4d3">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_CurrentImbalanceTripLevel" parent="Micro820" dataType="USInt" address="100088" va="0x4dc">
<mapping variable="cfg_I_CurrentImbalanceTripLevel" parent="Micro820" dataType="USInt" address="100088" va="0x4d4">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_CurrentImbalanceWarningLevel" parent="Micro820" dataType="USInt" address="100096" va="0x4dd">
<mapping variable="cfg_I_CurrentImbalanceWarningLevel" parent="Micro820" dataType="USInt" address="100096" va="0x4d5">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_JamInhibitTime" parent="Micro820" dataType="USInt" address="100104" va="0x4d5">
<mapping variable="cfg_I_JamInhibitTime" parent="Micro820" dataType="USInt" address="100104" va="0x4cd">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_JamTripDelay" parent="Micro820" dataType="USInt" address="100112" va="0x4d6">
<mapping variable="cfg_I_JamTripDelay" parent="Micro820" dataType="USInt" address="100112" va="0x4ce">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_LineLossInhibitTime" parent="Micro820" dataType="USInt" address="100120" va="0x4ec">
<mapping variable="cfg_I_LineLossInhibitTime" parent="Micro820" dataType="USInt" address="100120" va="0x4e4">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_OvercurrentInhibitTime" parent="Micro820" dataType="USInt" address="100128" va="0x4e5">
<mapping variable="cfg_I_OvercurrentInhibitTime" parent="Micro820" dataType="USInt" address="100128" va="0x4dd">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_OvercurrentTripLevel" parent="Micro820" dataType="USInt" address="100136" va="0x50e">
<mapping variable="cfg_I_OvercurrentTripLevel" parent="Micro820" dataType="USInt" address="100136" va="0x506">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_OvercurrentWarningLevel" parent="Micro820" dataType="USInt" address="100144" va="0x50f">
<mapping variable="cfg_I_OvercurrentWarningLevel" parent="Micro820" dataType="USInt" address="100144" va="0x507">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_StallEnabledTime" parent="Micro820" dataType="USInt" address="100152" va="0x4d4">
<mapping variable="cfg_I_StallEnabledTime" parent="Micro820" dataType="USInt" address="100152" va="0x4cc">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_TripEnableCurrent" parent="Micro820" dataType="UInt" address="100160" va="0x52a">
<mapping variable="cfg_I_TripEnableCurrent" parent="Micro820" dataType="UInt" address="100160" va="0x522">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="cfg_I_UndercurrentInhibitTime" parent="Micro820" dataType="USInt" address="100176" va="0x4de">
<mapping variable="cfg_I_UndercurrentInhibitTime" parent="Micro820" dataType="USInt" address="100176" va="0x4d6">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_C_WarningEnableControl" parent="Micro820" dataType="UInt" address="100184" va="0x538">
<mapping variable="cfg_C_WarningEnableControl" parent="Micro820" dataType="UInt" address="100184" va="0x530">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="cfg_I_UndercurrentTripLevel" parent="Micro820" dataType="USInt" address="100200" va="0x50c">
<mapping variable="cfg_I_UndercurrentTripLevel" parent="Micro820" dataType="USInt" address="100200" va="0x504">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_UndercurrentWarningLevel" parent="Micro820" dataType="USInt" address="100208" va="0x50d">
<mapping variable="cfg_I_UndercurrentWarningLevel" parent="Micro820" dataType="USInt" address="100208" va="0x505">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_UnderloadInhibitTime" parent="Micro820" dataType="USInt" address="100216" va="0x4d7">
<mapping variable="cfg_I_UnderloadInhibitTime" parent="Micro820" dataType="USInt" address="100216" va="0x4cf">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_UnderloadTripLevel" parent="Micro820" dataType="USInt" address="100224" va="0x4d8">
<mapping variable="cfg_I_UnderloadTripLevel" parent="Micro820" dataType="USInt" address="100224" va="0x4d0">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_UnderloadWarningLevel" parent="Micro820" dataType="USInt" address="100232" va="0x4d9">
<mapping variable="cfg_I_UnderloadWarningLevel" parent="Micro820" dataType="USInt" address="100232" va="0x4d1">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_I_WarningEnableCurrent" parent="Micro820" dataType="UInt" address="100240" va="0x532">
<mapping variable="cfg_I_WarningEnableCurrent" parent="Micro820" dataType="UInt" address="100240" va="0x52a">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="cfg_PL_PhaseLossInhibitTime" parent="Micro820" dataType="USInt" address="100256" va="0x4d2">
<mapping variable="cfg_PL_PhaseLossInhibitTime" parent="Micro820" dataType="USInt" address="100256" va="0x4ca">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_TCU_OLResetLevel" parent="Micro820" dataType="USInt" address="100264" va="0x4d0">
<mapping variable="cfg_TCU_OLResetLevel" parent="Micro820" dataType="USInt" address="100264" va="0x4c8">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_TCU_OLWarningLevel" parent="Micro820" dataType="USInt" address="100272" va="0x4d1">
<mapping variable="cfg_TCU_OLWarningLevel" parent="Micro820" dataType="USInt" address="100272" va="0x4c9">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_TCU_TripClass" parent="Micro820" dataType="USInt" address="100280" va="0x4cf">
<mapping variable="cfg_TCU_TripClass" parent="Micro820" dataType="USInt" address="100280" va="0x4c7">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_V_OverfrequencyInhibitTime" parent="Micro820" dataType="USInt" address="100288" va="0x4f8">
<mapping variable="cfg_V_OverfrequencyInhibitTime" parent="Micro820" dataType="USInt" address="100288" va="0x4f0">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_V_OverfrequencyTripLevel" parent="Micro820" dataType="USInt" address="100296" va="0x4f9">
<mapping variable="cfg_V_OverfrequencyTripLevel" parent="Micro820" dataType="USInt" address="100296" va="0x4f1">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_V_OverfrequencyWarningLevel" parent="Micro820" dataType="USInt" address="100304" va="0x4fa">
<mapping variable="cfg_V_OverfrequencyWarningLevel" parent="Micro820" dataType="USInt" address="100304" va="0x4f2">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_V_OvervoltageInhibitTime" parent="Micro820" dataType="USInt" address="100312" va="0x4ef">
<mapping variable="cfg_V_OvervoltageInhibitTime" parent="Micro820" dataType="USInt" address="100312" va="0x4e7">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_V_PhaseRotationInhibitTime" parent="Micro820" dataType="USInt" address="100320" va="0x4f0">
<mapping variable="cfg_V_PhaseRotationInhibitTime" parent="Micro820" dataType="USInt" address="100320" va="0x4e8">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_V_PhaseRotationTripType" parent="Micro820" dataType="USInt" address="100328" va="0x4f1">
<mapping variable="cfg_V_PhaseRotationTripType" parent="Micro820" dataType="USInt" address="100328" va="0x4e9">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_V_TripEnableVoltage" parent="Micro820" dataType="UInt" address="100336" va="0x52c">
<mapping variable="cfg_V_TripEnableVoltage" parent="Micro820" dataType="UInt" address="100336" va="0x524">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="cfg_V_UnderfrequencyInhibitTime" parent="Micro820" dataType="USInt" address="100352" va="0x4f5">
<mapping variable="cfg_V_UnderfrequencyInhibitTime" parent="Micro820" dataType="USInt" address="100352" va="0x4ed">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_V_UnderfrequencyTripLevel" parent="Micro820" dataType="USInt" address="100360" va="0x4f6">
<mapping variable="cfg_V_UnderfrequencyTripLevel" parent="Micro820" dataType="USInt" address="100360" va="0x4ee">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_V_UnderfrequencyWarningLevel" parent="Micro820" dataType="USInt" address="100368" va="0x4f7">
<mapping variable="cfg_V_UnderfrequencyWarningLevel" parent="Micro820" dataType="USInt" address="100368" va="0x4ef">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_V_UndervoltageInhibitTime" parent="Micro820" dataType="USInt" address="100376" va="0x4ee">
<mapping variable="cfg_V_UndervoltageInhibitTime" parent="Micro820" dataType="USInt" address="100376" va="0x4e6">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_V_VoltageImbalanceInhibitTime" parent="Micro820" dataType="USInt" address="100384" va="0x4f2">
<mapping variable="cfg_V_VoltageImbalanceInhibitTime" parent="Micro820" dataType="USInt" address="100384" va="0x4ea">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_V_VoltageImbalanceTripLevel" parent="Micro820" dataType="USInt" address="100392" va="0x4f3">
<mapping variable="cfg_V_VoltageImbalanceTripLevel" parent="Micro820" dataType="USInt" address="100392" va="0x4eb">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_V_VoltageImbalanceWarningLevel" parent="Micro820" dataType="USInt" address="100400" va="0x4f4">
<mapping variable="cfg_V_VoltageImbalanceWarningLevel" parent="Micro820" dataType="USInt" address="100400" va="0x4ec">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_V_VoltageMode" parent="Micro820" dataType="USInt" address="100408" va="0x4ed">
<mapping variable="cfg_V_VoltageMode" parent="Micro820" dataType="USInt" address="100408" va="0x4e5">
<MBVarInfo ElemType="USInt" SubElemType="Any" DataTypeSize="1" />
</mapping>
<mapping variable="cfg_V_WarningEnableVoltage" parent="Micro820" dataType="UInt" address="100416" va="0x534">
<mapping variable="cfg_V_WarningEnableVoltage" parent="Micro820" dataType="UInt" address="100416" va="0x52c">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="TripStatusControl_INT" parent="Micro820" dataType="UInt" address="100432" va="0x54e">
<mapping variable="TripStatusControl_INT" parent="Micro820" dataType="UInt" address="100432" va="0x546">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="TripStatusCurrent_INT" parent="Micro820" dataType="UInt" address="100448" va="0x548">
<mapping variable="TripStatusCurrent_INT" parent="Micro820" dataType="UInt" address="100448" va="0x540">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="TripStatusPower_INT" parent="Micro820" dataType="UInt" address="100464" va="0x54c">
<mapping variable="TripStatusPower_INT" parent="Micro820" dataType="UInt" address="100464" va="0x544">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="TripStatusVoltage_INT" parent="Micro820" dataType="UInt" address="100480" va="0x54a">
<mapping variable="TripStatusVoltage_INT" parent="Micro820" dataType="UInt" address="100480" va="0x542">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="WarningStatusControl_INT" parent="Micro820" dataType="UInt" address="100496" va="0x556">
<mapping variable="WarningStatusControl_INT" parent="Micro820" dataType="UInt" address="100496" va="0x54e">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="WarningStatusCurrent_INT" parent="Micro820" dataType="UInt" address="100512" va="0x550">
<mapping variable="WarningStatusCurrent_INT" parent="Micro820" dataType="UInt" address="100512" va="0x548">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="WarningStatusPower_INT" parent="Micro820" dataType="UInt" address="100528" va="0x554">
<mapping variable="WarningStatusPower_INT" parent="Micro820" dataType="UInt" address="100528" va="0x54c">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="WarningStatusVoltage_INT" parent="Micro820" dataType="UInt" address="100544" va="0x552">
<mapping variable="WarningStatusVoltage_INT" parent="Micro820" dataType="UInt" address="100544" va="0x54a">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
</modbusRegister>
<modbusRegister name="HOLDING_REGISTERS">
<mapping variable="cfg_C_FLASetting" parent="Micro820" dataType="Real" address="400001" va="0x58c">
<mapping variable="cfg_C_FLASetting" parent="Micro820" dataType="Real" address="400001" va="0x584">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_C_TripEnableControl" parent="Micro820" dataType="UInt" address="400003" va="0x530">
<mapping variable="cfg_C_TripEnableControl" parent="Micro820" dataType="UInt" address="400003" va="0x528">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="cfg_GF_GroundFaultTripDelay" parent="Micro820" dataType="Real" address="400005" va="0x594">
<mapping variable="cfg_GF_GroundFaultTripDelay" parent="Micro820" dataType="Real" address="400005" va="0x58c">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_GF_GroundFaultTripLevel" parent="Micro820" dataType="Real" address="400007" va="0x598">
<mapping variable="cfg_GF_GroundFaultTripLevel" parent="Micro820" dataType="Real" address="400007" va="0x590">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_GF_GroundFaultWarningDelay" parent="Micro820" dataType="Real" address="400009" va="0x59c">
<mapping variable="cfg_GF_GroundFaultWarningDelay" parent="Micro820" dataType="Real" address="400009" va="0x594">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_I_CTPrimary" parent="Micro820" dataType="UInt" address="400011" va="0x540">
<mapping variable="cfg_I_CTPrimary" parent="Micro820" dataType="UInt" address="400011" va="0x538">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="cfg_I_CTSecondary" parent="Micro820" dataType="UInt" address="400012" va="0x542">
<mapping variable="cfg_I_CTSecondary" parent="Micro820" dataType="UInt" address="400012" va="0x53a">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="cfg_I_JamTripLevel" parent="Micro820" dataType="UInt" address="400013" va="0x53c">
<mapping variable="cfg_I_JamTripLevel" parent="Micro820" dataType="UInt" address="400013" va="0x534">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="cfg_I_JamWarningLevel" parent="Micro820" dataType="UInt" address="400014" va="0x53e">
<mapping variable="cfg_I_JamWarningLevel" parent="Micro820" dataType="UInt" address="400014" va="0x536">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="cfg_I_LineLossTripDelay" parent="Micro820" dataType="Real" address="400015" va="0x660">
<mapping variable="cfg_I_LineLossTripDelay" parent="Micro820" dataType="Real" address="400015" va="0x658">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_I_OvercurrentTripDelay" parent="Micro820" dataType="Real" address="400017" va="0x664">
<mapping variable="cfg_I_OvercurrentTripDelay" parent="Micro820" dataType="Real" address="400017" va="0x65c">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_I_UndercurrentTripDelay" parent="Micro820" dataType="Real" address="400019" va="0x65c">
<mapping variable="cfg_I_UndercurrentTripDelay" parent="Micro820" dataType="Real" address="400019" va="0x654">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_I_UnderloadTripDelay" parent="Micro820" dataType="Real" address="400021" va="0x5a4">
<mapping variable="cfg_I_UnderloadTripDelay" parent="Micro820" dataType="Real" address="400021" va="0x59c">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_PL_PhaseLossTripDelay" parent="Micro820" dataType="Real" address="400023" va="0x590">
<mapping variable="cfg_PL_PhaseLossTripDelay" parent="Micro820" dataType="Real" address="400023" va="0x588">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_V_OverfrequencyTripDelay" parent="Micro820" dataType="Real" address="400025" va="0x5ec">
<mapping variable="cfg_V_OverfrequencyTripDelay" parent="Micro820" dataType="Real" address="400025" va="0x5e4">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_V_OvervoltageTripDelay" parent="Micro820" dataType="Real" address="400027" va="0x5d8">
<mapping variable="cfg_V_OvervoltageTripDelay" parent="Micro820" dataType="Real" address="400027" va="0x5d0">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_V_OvervoltageTripLevel" parent="Micro820" dataType="Real" address="400029" va="0x5dc">
<mapping variable="cfg_V_OvervoltageTripLevel" parent="Micro820" dataType="Real" address="400029" va="0x5d4">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_V_OvervoltageWarningLevel" parent="Micro820" dataType="Real" address="400031" va="0x5e0">
<mapping variable="cfg_V_OvervoltageWarningLevel" parent="Micro820" dataType="Real" address="400031" va="0x5d8">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_V_PTPrimary" parent="Micro820" dataType="UInt" address="400033" va="0x544">
<mapping variable="cfg_V_PTPrimary" parent="Micro820" dataType="UInt" address="400033" va="0x53c">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="cfg_V_PTSecondary" parent="Micro820" dataType="UInt" address="400034" va="0x546">
<mapping variable="cfg_V_PTSecondary" parent="Micro820" dataType="UInt" address="400034" va="0x53e">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="cfg_V_UnderfrequencyTripDelay" parent="Micro820" dataType="Real" address="400035" va="0x5e8">
<mapping variable="cfg_V_UnderfrequencyTripDelay" parent="Micro820" dataType="Real" address="400035" va="0x5e0">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_V_UndervoltageTripDelay" parent="Micro820" dataType="Real" address="400037" va="0x5cc">
<mapping variable="cfg_V_UndervoltageTripDelay" parent="Micro820" dataType="Real" address="400037" va="0x5c4">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_V_UndervoltageTripLevel" parent="Micro820" dataType="Real" address="400039" va="0x5d0">
<mapping variable="cfg_V_UndervoltageTripLevel" parent="Micro820" dataType="Real" address="400039" va="0x5c8">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_V_UndervoltageWarningLevel" parent="Micro820" dataType="Real" address="400041" va="0x5d4">
<mapping variable="cfg_V_UndervoltageWarningLevel" parent="Micro820" dataType="Real" address="400041" va="0x5cc">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="cfg_V_VoltageImbalanceTripDelay" parent="Micro820" dataType="Real" address="400043" va="0x5e4">
<mapping variable="cfg_V_VoltageImbalanceTripDelay" parent="Micro820" dataType="Real" address="400043" va="0x5dc">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="DH_DischargePressure" parent="Micro820" dataType="UInt" address="400045" va="0x514">
<mapping variable="DH_DischargePressure" parent="Micro820" dataType="UInt" address="400045" va="0x50c">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="DH_DischargeTemperature" parent="Micro820" dataType="UInt" address="400046" va="0x512">
<mapping variable="DH_DischargeTemperature" parent="Micro820" dataType="UInt" address="400046" va="0x50a">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="DH_DownholeStatus_INT" parent="Micro820" dataType="UInt" address="400047" va="0x528">
<mapping variable="DH_DownholeStatus_INT" parent="Micro820" dataType="UInt" address="400047" va="0x520">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="DH_IntakePressure" parent="Micro820" dataType="Real" address="400048" va="0x568">
<mapping variable="DH_IntakePressure" parent="Micro820" dataType="Real" address="400048" va="0x560">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="DH_IntakeTemperature" parent="Micro820" dataType="Real" address="400050" va="0x564">
<mapping variable="DH_IntakeTemperature" parent="Micro820" dataType="Real" address="400050" va="0x55c">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="DH_MaxIntakePressure_Forever" parent="Micro820" dataType="UInt" address="400052" va="0x526">
<mapping variable="DH_MaxIntakePressure_Forever" parent="Micro820" dataType="UInt" address="400052" va="0x51e">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="DH_MaxIntakePressure_Startup" parent="Micro820" dataType="UInt" address="400053" va="0x520">
<mapping variable="DH_MaxIntakePressure_Startup" parent="Micro820" dataType="UInt" address="400053" va="0x518">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="DH_MaxIntakeTemperature_Forever" parent="Micro820" dataType="Real" address="400054" va="0x588">
<mapping variable="DH_MaxIntakeTemperature_Forever" parent="Micro820" dataType="Real" address="400054" va="0x580">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="DH_MaxIntakeTemperature_Startup" parent="Micro820" dataType="Real" address="400056" va="0x584">
<mapping variable="DH_MaxIntakeTemperature_Startup" parent="Micro820" dataType="Real" address="400056" va="0x57c">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="DH_NumChannels" parent="Micro820" dataType="UInt" address="400058" va="0x51c">
<mapping variable="DH_NumChannels" parent="Micro820" dataType="UInt" address="400058" va="0x514">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="DH_PSIRating" parent="Micro820" dataType="UInt" address="400059" va="0x524">
<mapping variable="DH_PSIRating" parent="Micro820" dataType="UInt" address="400059" va="0x51c">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="DH_ToolType" parent="Micro820" dataType="UInt" address="400060" va="0x522">
<mapping variable="DH_ToolType" parent="Micro820" dataType="UInt" address="400060" va="0x51a">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="DH_ToolVoltage" parent="Micro820" dataType="UInt" address="400061" va="0x51e">
<mapping variable="DH_ToolVoltage" parent="Micro820" dataType="UInt" address="400061" va="0x516">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="DH_VibrationX" parent="Micro820" dataType="UInt" address="400062" va="0x516">
<mapping variable="DH_VibrationX" parent="Micro820" dataType="UInt" address="400062" va="0x50e">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="DH_VibrationY" parent="Micro820" dataType="UInt" address="400063" va="0x518">
<mapping variable="DH_VibrationY" parent="Micro820" dataType="UInt" address="400063" va="0x510">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="DH_WindingTemperature" parent="Micro820" dataType="UInt" address="400064" va="0x510">
<mapping variable="DH_WindingTemperature" parent="Micro820" dataType="UInt" address="400064" va="0x508">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="E300_kWh" parent="Micro820" dataType="Real" address="400065" va="0x57c">
<mapping variable="E300_kWh" parent="Micro820" dataType="Real" address="400065" va="0x574">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_kWh_Regen" parent="Micro820" dataType="Real" address="400067" va="0x580">
<mapping variable="E300_kWh_Regen" parent="Micro820" dataType="Real" address="400067" va="0x578">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_SCAN_RATE" parent="Micro820" dataType="UInt" address="400069" va="0x51a">
<mapping variable="E300_SCAN_RATE" parent="Micro820" dataType="UInt" address="400069" va="0x512">
<MBVarInfo ElemType="UInt" SubElemType="Any" DataTypeSize="2" />
</mapping>
<mapping variable="Pressure_Shutdown" parent="Micro820" dataType="Real" address="400070" va="0x574">
<mapping variable="Pressure_Shutdown" parent="Micro820" dataType="Real" address="400070" va="0x56c">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="Pressure_Startup" parent="Micro820" dataType="Real" address="400072" va="0x578">
<mapping variable="Pressure_Startup" parent="Micro820" dataType="Real" address="400072" va="0x570">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="Temp_Shutdown" parent="Micro820" dataType="Real" address="400074" va="0x56c">
<mapping variable="Temp_Shutdown" parent="Micro820" dataType="Real" address="400074" va="0x564">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="Temp_Startup" parent="Micro820" dataType="Real" address="400076" va="0x570">
<mapping variable="Temp_Startup" parent="Micro820" dataType="Real" address="400076" va="0x568">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_LineFrequency" parent="Micro820" dataType="Real" address="400078" va="0x668">
<mapping variable="E300_LineFrequency" parent="Micro820" dataType="Real" address="400078" va="0x660">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L1Current" parent="Micro820" dataType="Real" address="400080" va="0x66c">
<mapping variable="E300_L1Current" parent="Micro820" dataType="Real" address="400080" va="0x664">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L2Current" parent="Micro820" dataType="Real" address="400082" va="0x670">
<mapping variable="E300_L2Current" parent="Micro820" dataType="Real" address="400082" va="0x668">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L3Current" parent="Micro820" dataType="Real" address="400084" va="0x674">
<mapping variable="E300_L3Current" parent="Micro820" dataType="Real" address="400084" va="0x66c">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_AverageCurrent" parent="Micro820" dataType="Real" address="400086" va="0x678">
<mapping variable="E300_AverageCurrent" parent="Micro820" dataType="Real" address="400086" va="0x670">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_PercentCurrentUnbalance" parent="Micro820" dataType="Real" address="400088" va="0x67c">
<mapping variable="E300_PercentCurrentUnbalance" parent="Micro820" dataType="Real" address="400088" va="0x674">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L1NVoltage" parent="Micro820" dataType="Real" address="400090" va="0x680">
<mapping variable="E300_L1NVoltage" parent="Micro820" dataType="Real" address="400090" va="0x678">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L2NVoltage" parent="Micro820" dataType="Real" address="400092" va="0x684">
<mapping variable="E300_L2NVoltage" parent="Micro820" dataType="Real" address="400092" va="0x67c">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L3NVoltage" parent="Micro820" dataType="Real" address="400094" va="0x688">
<mapping variable="E300_L3NVoltage" parent="Micro820" dataType="Real" address="400094" va="0x680">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_AverageLNVoltage" parent="Micro820" dataType="Real" address="400096" va="0x68c">
<mapping variable="E300_AverageLNVoltage" parent="Micro820" dataType="Real" address="400096" va="0x684">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L1L2Voltage" parent="Micro820" dataType="Real" address="400098" va="0x690">
<mapping variable="E300_L1L2Voltage" parent="Micro820" dataType="Real" address="400098" va="0x688">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L2L3Voltage" parent="Micro820" dataType="Real" address="400100" va="0x694">
<mapping variable="E300_L2L3Voltage" parent="Micro820" dataType="Real" address="400100" va="0x68c">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L3L1Voltage" parent="Micro820" dataType="Real" address="400102" va="0x698">
<mapping variable="E300_L3L1Voltage" parent="Micro820" dataType="Real" address="400102" va="0x690">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_AverageLLVoltage" parent="Micro820" dataType="Real" address="400104" va="0x69c">
<mapping variable="E300_AverageLLVoltage" parent="Micro820" dataType="Real" address="400104" va="0x694">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L1RealPower" parent="Micro820" dataType="Real" address="400106" va="0x6a4">
<mapping variable="E300_L1RealPower" parent="Micro820" dataType="Real" address="400106" va="0x69c">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L2RealPower" parent="Micro820" dataType="Real" address="400108" va="0x6a8">
<mapping variable="E300_L2RealPower" parent="Micro820" dataType="Real" address="400108" va="0x6a0">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L3RealPower" parent="Micro820" dataType="Real" address="400110" va="0x6ac">
<mapping variable="E300_L3RealPower" parent="Micro820" dataType="Real" address="400110" va="0x6a4">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_TotalRealPower" parent="Micro820" dataType="Real" address="400112" va="0x6b0">
<mapping variable="E300_TotalRealPower" parent="Micro820" dataType="Real" address="400112" va="0x6a8">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L1ReactivePower" parent="Micro820" dataType="Real" address="400114" va="0x6b4">
<mapping variable="E300_L1ReactivePower" parent="Micro820" dataType="Real" address="400114" va="0x6ac">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L2ReactivePower" parent="Micro820" dataType="Real" address="400116" va="0x6b8">
<mapping variable="E300_L2ReactivePower" parent="Micro820" dataType="Real" address="400116" va="0x6b0">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L3ReactivePower" parent="Micro820" dataType="Real" address="400118" va="0x6bc">
<mapping variable="E300_L3ReactivePower" parent="Micro820" dataType="Real" address="400118" va="0x6b4">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_TotalReactivePower" parent="Micro820" dataType="Real" address="400120" va="0x6c0">
<mapping variable="E300_TotalReactivePower" parent="Micro820" dataType="Real" address="400120" va="0x6b8">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L1ApparentPower" parent="Micro820" dataType="Real" address="400122" va="0x6c4">
<mapping variable="E300_L1ApparentPower" parent="Micro820" dataType="Real" address="400122" va="0x6bc">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L2ApparentPower" parent="Micro820" dataType="Real" address="400124" va="0x6c8">
<mapping variable="E300_L2ApparentPower" parent="Micro820" dataType="Real" address="400124" va="0x6c0">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L3ApparentPower" parent="Micro820" dataType="Real" address="400126" va="0x6cc">
<mapping variable="E300_L3ApparentPower" parent="Micro820" dataType="Real" address="400126" va="0x6c4">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_TotalApparentPower" parent="Micro820" dataType="Real" address="400128" va="0x6d0">
<mapping variable="E300_TotalApparentPower" parent="Micro820" dataType="Real" address="400128" va="0x6c8">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L1TruePowerFactor" parent="Micro820" dataType="Real" address="400130" va="0x6d4">
<mapping variable="E300_L1TruePowerFactor" parent="Micro820" dataType="Real" address="400130" va="0x6cc">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L2TruePowerFactor" parent="Micro820" dataType="Real" address="400132" va="0x6d8">
<mapping variable="E300_L2TruePowerFactor" parent="Micro820" dataType="Real" address="400132" va="0x6d0">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_L3TruePowerFactor" parent="Micro820" dataType="Real" address="400134" va="0x6dc">
<mapping variable="E300_L3TruePowerFactor" parent="Micro820" dataType="Real" address="400134" va="0x6d4">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="E300_ThreePhaseTruePowerFactor" parent="Micro820" dataType="Real" address="400136" va="0x6e0">
<mapping variable="E300_ThreePhaseTruePowerFactor" parent="Micro820" dataType="Real" address="400136" va="0x6d8">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
<mapping variable="Pressure_In" parent="Micro820" dataType="Real" address="400138" va="0x6e4">
<mapping variable="Pressure_In" parent="Micro820" dataType="Real" address="400138" va="0x6dc">
<MBVarInfo ElemType="Real" SubElemType="Any" DataTypeSize="4" />
</mapping>
</modbusRegister>

View File

@@ -462,7 +462,6 @@ __TMPB1 := __TMPB1 _AND RUN_PERMISSIVE
_IF _NOT __TMPB1 _GOTO __LAB3f
CMD_RUN := TRUE
RESTART_COMMAND := FALSE
START_COMMAND := FALSE
__TMPB1 := _NOT START_TIME_SET
_IF _NOT __TMPB1 _GOTO __LAB40
START_TIME := TIME_CURRENTTIME
@@ -483,53 +482,60 @@ _GOTO __LAB44
__LAB3f :
CMD_RUN := FALSE
__LAB44 :
__FBL_RET := _PUSHCALLFB TON UNSTICK_STARTCOMMAND
__TMPB1 := UNSTICK_STARTCOMMAND [ __CDINT00000004 ]
_IF _NOT __TMPB1 _GOTO __LAB45
START_COMMAND := FALSE
_GOTO __LAB46
__LAB45 :
__LAB46 :
__TMPB1 := _NOT CONTACTOR_STATUS
__TMPB2 := CMD_RUN _AND __TMPB1
_IF _NOT __TMPB2 _GOTO __LAB45
_IF _NOT __TMPB2 _GOTO __LAB47
__TMPB3 := _NOT E300_OUTPUT_ENABLE
_IF _NOT __TMPB3 _GOTO __LAB46
_IF _NOT E300_OUTPUT_TOGGLED _GOTO __LAB47
_IF _NOT __TMPB3 _GOTO __LAB48
_IF _NOT E300_OUTPUT_TOGGLED _GOTO __LAB49
E300_OUTPUT_ENABLE := TRUE
_GOTO __LAB48
__LAB47 :
__LAB48 :
E300_OUTPUT_TOGGLED := TRUE
_GOTO __LAB49
__LAB46 :
__TMPB1 := _NOT E300_OUTPUT_TOGGLED
_IF _NOT __TMPB1 _GOTO __LAB4a
E300_OUTPUT_ENABLE := FALSE
_GOTO __LAB4b
__LAB4a :
__LAB4b :
_GOTO __LAB4a
__LAB49 :
_GOTO __LAB4c
__LAB45 :
__LAB4a :
E300_OUTPUT_TOGGLED := TRUE
_GOTO __LAB4b
__LAB48 :
__TMPB1 := _NOT E300_OUTPUT_TOGGLED
_IF _NOT __TMPB1 _GOTO __LAB4c
E300_OUTPUT_ENABLE := FALSE
_GOTO __LAB4d
__LAB4c :
__LAB4d :
__LAB4b :
_GOTO __LAB4e
__LAB47 :
__LAB4e :
__TMPB1 := RUN_TIME > CFG_CLEARTRIPCOUNTAFTER
__TMPB2 := CONTACTOR_STATUS _AND __TMPB1
_IF _NOT __TMPB2 _GOTO __LAB4d
_IF _NOT __TMPB2 _GOTO __LAB4f
VAL_OVERLOADTRIPCOUNT := __DINT_NULL
VAL_TRIPCOUNT := __DINT_NULL
_GOTO __LAB4e
__LAB4d :
__LAB4e :
__TMPB1 := _NOT AUTO_MODE
_IF _NOT __TMPB1 _GOTO __LAB4f
RESTART_COMMAND := FALSE
RESTART_ALLOWED := FALSE
_GOTO __LAB50
__LAB4f :
__LAB50 :
__FBL_RET := _PUSHCALLFB R_TRIG RTRIG_AUTOMODE
__TMPB1 := RTRIG_AUTOMODE [ __CDINT00000002 ]
__TMPB1 := _NOT AUTO_MODE
_IF _NOT __TMPB1 _GOTO __LAB51
RESTART_ALLOWED := TRUE
SHUTDOWN_TIME := TIME_CURRENTTIME
RESTART_COMMAND := FALSE
RESTART_ALLOWED := FALSE
_GOTO __LAB52
__LAB51 :
__LAB52 :
_IF _NOT STOP_COMMAND _GOTO __LAB53
__FBL_RET := _PUSHCALLFB R_TRIG RTRIG_AUTOMODE
__TMPB1 := RTRIG_AUTOMODE [ __CDINT00000002 ]
_IF _NOT __TMPB1 _GOTO __LAB53
RESTART_ALLOWED := TRUE
SHUTDOWN_TIME := TIME_CURRENTTIME
_GOTO __LAB54
__LAB53 :
__LAB54 :
_IF _NOT STOP_COMMAND _GOTO __LAB55
RESTART_ALLOWED := FALSE
DEVICE_STATUS := __TMPM23
DEVICE_STATUS_INT := __CUINT0000000A
@@ -538,104 +544,110 @@ VAL_OVERLOADTRIPCOUNT := __DINT_NULL
VAL_TRIPCOUNT := __DINT_NULL
CMD_TIMERRUN := FALSE
STS_TIMERRUNTIMESET := FALSE
_GOTO __LAB54
__LAB53 :
__LAB54 :
__TMPB1 := _NOT CONTACTOR_STATUS
_IF _NOT __TMPB1 _GOTO __LAB56
STOP_COMMAND := FALSE
_GOTO __LAB57
__LAB56 :
__LAB57 :
_GOTO __LAB58
__LAB55 :
__LAB58 :
__TMPB1 := _NOT HAND_MODE
__TMPB2 := _NOT AUTO_MODE
__TMPB1 := __TMPB1 _AND __TMPB2
_IF _NOT __TMPB1 _GOTO __LAB55
_IF _NOT __TMPB1 _GOTO __LAB59
VAL_OVERLOADTRIPCOUNT := __DINT_NULL
VAL_TRIPCOUNT := __DINT_NULL
CMD_TIMERRUN := FALSE
STS_TIMERCYCLEACTIVE := FALSE
STS_TIMERRUNTIMESET := FALSE
_GOTO __LAB56
__LAB55 :
__LAB56 :
_GOTO __LAB5a
__LAB59 :
__LAB5a :
__TMPB1 := _NOT CONTACTOR_STATUS
_IF _NOT __TMPB1 _GOTO __LAB57
_IF _NOT __TMPB1 _GOTO __LAB5b
START_TIME_SET := FALSE
_GOTO __LAB58
__LAB57 :
__LAB58 :
__TMPB1 := CFG_TIMERMODEENABLED _AND STS_TIMERCYCLEACTIVE
_IF _NOT __TMPB1 _GOTO __LAB59
_IF _NOT CMD_TIMERRUN _GOTO __LAB5a
__TMPB2 := _NOT STS_TIMERRUNTIMESET
_IF _NOT __TMPB2 _GOTO __LAB5b
STS_TIMERRUNTIMESET := TRUE
TIME_TIMERRUNTIME := TIME_CURRENTTIME
_GOTO __LAB5c
__LAB5b :
__LAB5c :
__TMPB1 := CFG_TIMERMODEENABLED _AND STS_TIMERCYCLEACTIVE
_IF _NOT __TMPB1 _GOTO __LAB5d
_IF _NOT CMD_TIMERRUN _GOTO __LAB5e
__TMPB2 := _NOT STS_TIMERRUNTIMESET
_IF _NOT __TMPB2 _GOTO __LAB5f
STS_TIMERRUNTIMESET := TRUE
TIME_TIMERRUNTIME := TIME_CURRENTTIME
_GOTO __LAB60
__LAB5f :
__LAB60 :
__TMPI1 := CFG_TIMERRUNTIME * __CDINT0000003C
__TMPI2 := TIME_CURRENTTIME - TIME_TIMERRUNTIME
__TMPI1 := __TMPI1 - __TMPI2
TIMER_RUNTIMELEFT := __TMPI1
__TMPB1 := TIMER_RUNTIMELEFT <= __DINT_NULL
_IF _NOT __TMPB1 _GOTO __LAB5d
_IF _NOT __TMPB1 _GOTO __LAB61
CMD_TIMERRUN := FALSE
STS_TIMERRUNTIMESET := FALSE
_GOTO __LAB5e
__LAB5d :
__LAB5e :
_GOTO __LAB62
__LAB61 :
__LAB62 :
__TMPI1 := TIMER_RUNTIMELEFT / __CDINT0000003C
TIME_RUNTIMELEFTMIN := __TMPI1
__TMPI1 := TIME_RUNTIMELEFTMIN * __CDINT0000003C
__TMPI2 := TIMER_RUNTIMELEFT - __TMPI1
TIME_RUNTIMELEFTSEC := __TMPI2
_GOTO __LAB5f
__LAB5a :
_GOTO __LAB63
__LAB5e :
__TMPB1 := _NOT STS_TIMERWAITTIMESET
_IF _NOT __TMPB1 _GOTO __LAB60
_IF _NOT __TMPB1 _GOTO __LAB64
STS_TIMERWAITTIMESET := TRUE
TIME_TIMERWAITTIME := TIME_CURRENTTIME
DEVICE_STATUS := __TMPM24
DEVICE_STATUS_INT := __CUINT0000000B
_GOTO __LAB61
__LAB60 :
__LAB61 :
_GOTO __LAB65
__LAB64 :
__LAB65 :
__TMPI1 := CFG_TIMERWAITTIME * __CDINT0000003C
__TMPI2 := TIME_CURRENTTIME - TIME_TIMERWAITTIME
__TMPI1 := __TMPI1 - __TMPI2
TIMER_WAITTIMELEFT := __TMPI1
__TMPB1 := TIMER_WAITTIMELEFT <= __DINT_NULL
_IF _NOT __TMPB1 _GOTO __LAB62
_IF _NOT __TMPB1 _GOTO __LAB66
CMD_TIMERRUN := TRUE
STS_TIMERWAITTIMESET := FALSE
_GOTO __LAB63
__LAB62 :
__LAB63 :
_GOTO __LAB67
__LAB66 :
__LAB67 :
__TMPI1 := TIMER_WAITTIMELEFT / __CDINT0000003C
TIME_WAITTIMELEFTMIN := __TMPI1
__TMPI1 := TIME_WAITTIMELEFTMIN * __CDINT0000003C
__TMPI2 := TIMER_WAITTIMELEFT - __TMPI1
TIME_WAITTIMELEFTSEC := __TMPI2
__LAB5f :
_GOTO __LAB64
__LAB59 :
__LAB64 :
__LAB63 :
_GOTO __LAB68
__LAB5d :
__LAB68 :
__TMPB1 := _NOT CFG_TIMERMODEENABLED
__TMPB1 := __TMPB1 _OR STOP_COMMAND
_IF _NOT __TMPB1 _GOTO __LAB65
_IF _NOT __TMPB1 _GOTO __LAB69
CMD_TIMERRUN := FALSE
STS_TIMERRUNTIMESET := FALSE
STS_TIMERWAITTIMESET := FALSE
_GOTO __LAB66
__LAB65 :
__LAB66 :
_GOTO __LAB6a
__LAB69 :
__LAB6a :
__TMPB1 := TRIPSTATUS _OR OVERLOADTRIP
_IF _NOT __TMPB1 _GOTO __LAB67
_IF _NOT __TMPB1 _GOTO __LAB6b
_PUSH_PAR TIME_CURRENTTIME
_PUSH_PAR CFG_RESETCYCLE
__TMPI1 := _CALL MOD
__TMPB2 := __TMPI1 = __DINT_NULL
_IF _NOT __TMPB2 _GOTO __LAB68
_IF _NOT __TMPB2 _GOTO __LAB6c
TRIPRESETCMD := TRUE
_GOTO __LAB69
__LAB68 :
__LAB69 :
_GOTO __LAB6a
__LAB67 :
__LAB6a :
_GOTO __LAB6d
__LAB6c :
__LAB6d :
_GOTO __LAB6e
__LAB6b :
__LAB6e :

View File

@@ -55,6 +55,8 @@ E300_READENERGY.INT_COP.__DTI_SRC@E300DATA,<NOT USED>,SINT
E300_READENERGY.INT_COP.__DTI_DEST@E300DATA,<NOT USED>,SINT
MODBUSCYCLETIMER.IN@READDOWNHOLEDATA,__TMPB__TON__IN,BOOL
MODBUSCYCLETIMER.PT@READDOWNHOLEDATA,MODBUSCYCLETIME,TIME
UNSTICK_STARTCOMMAND.IN@CONTROL,START_COMMAND,BOOL
UNSTICK_STARTCOMMAND.PT@CONTROL,STARTCOMMANDTIME@CONTROL,TIME
TON_TOTALIZER.IN@FLOWTOTALIZER,__TMPB__TON__IN,BOOL
TON_TOTALIZER.PT@FLOWTOTALIZER,__CTIME00002710,TIME
WRITEE300CONFIGDATA.FBEN@E300DATA,TRUE,BOOL

View File

@@ -1,51 +1,51 @@
0::0046-0003::-------------------- Pre-build resource: MICRO820 Configuration: MICRO820 --------------
0::0044-0003::Pre-compiling for 2080LC2020QWBI
0::0000-0003::RA_CIP_ELECTRICAL_ENERGY_OBJ
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\RA_CIP_ELECTRICAL_ENERGY_OBJ:0000-0003::RA_E300_OUTPUT_CONTROL
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\RA_E300_OUTPUT_CONTROL:0000-0003::READE300IO
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300IO:0000-0003::READE300CONFIG
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300CONFIG:0000-0003::READE300TRIPRESET
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300TRIPRESET:0000-0003::READE300PARAM
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300PARAM:0000-0003::USINT_TO_UDINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_UDINT:0000-0003::USINT_TO_DINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_DINT:0000-0003::USINT_TO_UINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_UINT:0000-0003::USINT_TO_SINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_SINT:0000-0003::UDINT_TO_USINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\UDINT_TO_USINT:0000-0003::DINT_TO_USINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\DINT_TO_USINT:0000-0003::UINT_TO_USINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\UINT_TO_USINT:0000-0003::SINT_TO_USINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\SINT_TO_USINT:0000-0003::WRITEE300CONFIG
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\WRITEE300CONFIG:0000-0003::WRITEE300TRIPRESET
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\WRITEE300TRIPRESET:0000-0003::LINEARSCALE
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\LINEARSCALE:0000-0003::EPOCH_TIME
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\EPOCH_TIME:0000-0003::READDOWNHOLEDATA
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READDOWNHOLEDATA:0000-0003::E300DATA
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\E300DATA:0000-0003::CONTROL
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\CONTROL:0000-0003::FLOWTOTALIZER
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\FLOWTOTALIZER:0002-0003::MICRO820: 0 error(s), 0 warning(s)
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\RA_CIP_ELECTRICAL_ENERGY_OBJ:0000-0003::RA_E300_OUTPUT_CONTROL
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\RA_E300_OUTPUT_CONTROL:0000-0003::READE300IO
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300IO:0000-0003::READE300CONFIG
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300CONFIG:0000-0003::READE300TRIPRESET
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300TRIPRESET:0000-0003::READE300PARAM
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300PARAM:0000-0003::USINT_TO_UDINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_UDINT:0000-0003::USINT_TO_DINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_DINT:0000-0003::USINT_TO_UINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_UINT:0000-0003::USINT_TO_SINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_SINT:0000-0003::UDINT_TO_USINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\UDINT_TO_USINT:0000-0003::DINT_TO_USINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\DINT_TO_USINT:0000-0003::UINT_TO_USINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\UINT_TO_USINT:0000-0003::SINT_TO_USINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\SINT_TO_USINT:0000-0003::WRITEE300CONFIG
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\WRITEE300CONFIG:0000-0003::WRITEE300TRIPRESET
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\WRITEE300TRIPRESET:0000-0003::LINEARSCALE
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\LINEARSCALE:0000-0003::EPOCH_TIME
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\EPOCH_TIME:0000-0003::READDOWNHOLEDATA
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READDOWNHOLEDATA:0000-0003::E300DATA
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\E300DATA:0000-0003::CONTROL
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\CONTROL:0000-0003::FLOWTOTALIZER
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\FLOWTOTALIZER:0002-0003::MICRO820: 0 error(s), 0 warning(s)
0::0006-0003::-------------------- Build resource: MICRO820 Configuration: MICRO820 --------------
0::0001-0003::Compiling for 2080LC2020QWBI
0::0000-0003::RA_CIP_ELECTRICAL_ENERGY_OBJ
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\RA_CIP_ELECTRICAL_ENERGY_OBJ:0000-0003::RA_E300_OUTPUT_CONTROL
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\RA_E300_OUTPUT_CONTROL:0000-0003::READE300IO
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300IO:0000-0003::READE300CONFIG
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300CONFIG:0000-0003::READE300TRIPRESET
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300TRIPRESET:0000-0003::READE300PARAM
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300PARAM:0000-0003::USINT_TO_UDINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_UDINT:0000-0003::USINT_TO_DINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_DINT:0000-0003::USINT_TO_UINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_UINT:0000-0003::USINT_TO_SINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_SINT:0000-0003::UDINT_TO_USINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\UDINT_TO_USINT:0000-0003::DINT_TO_USINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\DINT_TO_USINT:0000-0003::UINT_TO_USINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\UINT_TO_USINT:0000-0003::SINT_TO_USINT
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\SINT_TO_USINT:0000-0003::WRITEE300CONFIG
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\WRITEE300CONFIG:0000-0003::WRITEE300TRIPRESET
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\WRITEE300TRIPRESET:0000-0003::LINEARSCALE
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\LINEARSCALE:0000-0003::EPOCH_TIME
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\EPOCH_TIME:0000-0003::READDOWNHOLEDATA
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READDOWNHOLEDATA:0000-0003::E300DATA
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\E300DATA:0000-0003::CONTROL
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\CONTROL:0000-0003::FLOWTOTALIZER
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\FLOWTOTALIZER:0003-0003::Linking for 2080LC2020QWBI
0:C:\USERS\PATRI\DOCUMENTS\HENRY_PUMP\E300-IPP\CONTROLLER\CONTROLLER\MICRO820\MICRO820\FLOWTOTALIZER:0002-0003::MICRO820: 0 error(s), 0 warning(s)
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\RA_CIP_ELECTRICAL_ENERGY_OBJ:0000-0003::RA_E300_OUTPUT_CONTROL
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\RA_E300_OUTPUT_CONTROL:0000-0003::READE300IO
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300IO:0000-0003::READE300CONFIG
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300CONFIG:0000-0003::READE300TRIPRESET
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300TRIPRESET:0000-0003::READE300PARAM
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READE300PARAM:0000-0003::USINT_TO_UDINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_UDINT:0000-0003::USINT_TO_DINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_DINT:0000-0003::USINT_TO_UINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_UINT:0000-0003::USINT_TO_SINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\USINT_TO_SINT:0000-0003::UDINT_TO_USINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\UDINT_TO_USINT:0000-0003::DINT_TO_USINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\DINT_TO_USINT:0000-0003::UINT_TO_USINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\UINT_TO_USINT:0000-0003::SINT_TO_USINT
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\SINT_TO_USINT:0000-0003::WRITEE300CONFIG
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\WRITEE300CONFIG:0000-0003::WRITEE300TRIPRESET
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\WRITEE300TRIPRESET:0000-0003::LINEARSCALE
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\LINEARSCALE:0000-0003::EPOCH_TIME
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\EPOCH_TIME:0000-0003::READDOWNHOLEDATA
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\READDOWNHOLEDATA:0000-0003::E300DATA
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\E300DATA:0000-0003::CONTROL
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\CONTROL:0000-0003::FLOWTOTALIZER
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\FLOWTOTALIZER:0003-0003::Linking for 2080LC2020QWBI
0:C:\USERS\PATRICK\DOCUMENTS\HENRY_PUMP\IPP_PANEL\CONTROLLER\CONTROLLER\MICRO820\MICRO820\FLOWTOTALIZER:0002-0003::MICRO820: 0 error(s), 0 warning(s)

View File

@@ -1,10 +1,10 @@
[MEMORY]
Offset0=0x4540
Offset1=0x5540
Offset2=0x5540
Offset3=0x5540
Memory Usage Estimate(Code)=0xA154
Memory Usage Estimate(Data)=0x9E20
Offset0=0x4550
Offset1=0x5550
Offset2=0x5550
Offset3=0x5550
Memory Usage Estimate(Code)=0xA180
Memory Usage Estimate(Data)=0x9E30
Memory Usage Estimate(Retain)=0x50
Memory Usage Estimate(Temporary variables)=0x28DC
Offset4=0x414

View File

@@ -1,10 +1,10 @@
[MEMORY]
Offset0=0x4540
Offset1=0x5540
Offset2=0x5540
Offset3=0x5540
Memory Usage Estimate(Code)=0xA154
Memory Usage Estimate(Data)=0x9E20
Offset0=0x4550
Offset1=0x5550
Offset2=0x5550
Offset3=0x5550
Memory Usage Estimate(Code)=0xA180
Memory Usage Estimate(Data)=0x9E30
Memory Usage Estimate(Retain)=0x50
Memory Usage Estimate(Temporary variables)=0x28DC
Offset4=0x414

View File

@@ -5,12 +5,12 @@ ON_LINE=N
TBL_CONF=Y
CRC_ORG=0x0
CRC_OLD=
CRC_NEW=0x463526FC
CRC_NEW=0x590030C1
DAT_ORG=0
DAT_OLD=0
DAT_NEW=1473283229
DAT_NEW=1473953978
VER_ORG=0
VER_OLD=0
VER_NEW=91
VER_NEW=93
CRC_ALL_OLD=
CRC_ALL_NEW=0xA673C34C
CRC_ALL_NEW=0x608693B5

View File

@@ -2,8 +2,8 @@
Memory Usage Estimate(Temporary variables)=0x28DC
Biggest online change user variable memory block size=0x800
Currently added user variables=0x0
Total data size=0x6E1C
User variables size=0x4540
Total data size=0x6E2C
User variables size=0x4550
Maximum size for temporary variables=0x48DC
Memory Usage Estimate(Data)=0x9E1C
Memory Usage Estimate(Data)=0x9E2C
Free memory for user variables=0x1000

View File

@@ -2,8 +2,8 @@
Memory Usage Estimate(Temporary variables)=0x28DC
Biggest online change user variable memory block size=0x800
Currently added user variables=0x0
Total data size=0x6E1C
User variables size=0x4540
Total data size=0x6E2C
User variables size=0x4550
Maximum size for temporary variables=0x48DC
Memory Usage Estimate(Data)=0x9E1C
Memory Usage Estimate(Data)=0x9E2C
Free memory for user variables=0x1000

View File

@@ -1,4 +1,5 @@
<INPUT>,CURRENTTIMERTC,EPOCH_TIME,RTC_READ_ENABLED,TRUE,BOOL
<INPUT>,LINEARSCALE_PRESSURE@CONTROL,LINEARSCALE,RAW_MIN,__TMPR1@CONTROL,REAL,RAW_MAX,__TMPR2@CONTROL,REAL,EU_MIN,PRESSURE_EU_MIN,REAL,EU_MAX,PRESSURE_EU_MAX,REAL,RAW_INP,__TMPR__LINEARSCALE__RAW_INP,REAL
<INPUT>,LINEARSCALE_FLOW@CONTROL,LINEARSCALE,RAW_MIN,__TMPR1@CONTROL,REAL,RAW_MAX,__TMPR2@CONTROL,REAL,EU_MIN,FLOW_EU_MIN,REAL,EU_MAX,FLOW_EU_MAX,REAL,RAW_INP,__TMPR__LINEARSCALE__RAW_INP,REAL
<INPUT>,UNSTICK_STARTCOMMAND@CONTROL,TON,IN,START_COMMAND,BOOL,PT,STARTCOMMANDTIME@CONTROL,TIME
<INPUT>,RTRIG_AUTOMODE@CONTROL,R_TRIG,CLK,AUTO_MODE,BOOL

View File

@@ -66,11 +66,9 @@ MDF = 1\1, 1, 0, 0, -1, _IO_EM_AO_00
RIdx = 0, 1, 4
Nb = 0
RIdx = 0, 1, 5
Nb = 4
Nb = 2
MDF = 1\1, 0, 0, 0, -1, _IO_P1_AI_00
MDF = 1\1, 0, 0, 1, -1, _IO_P1_AI_01
MDF = 1\1, 0, 0, 2, -1, _IO_P1_AI_02
MDF = 1\1, 0, 0, 3, -1, _IO_P1_AI_03
[__READONLY_VALUES]

View File

@@ -66,11 +66,9 @@ MDF = 1\1, 1, 0, 0, -1, _IO_EM_AO_00
RIdx = 0, 1, 4
Nb = 0
RIdx = 0, 1, 5
Nb = 4
Nb = 2
MDF = 1\1, 0, 0, 0, -1, _IO_P1_AI_00
MDF = 1\1, 0, 0, 1, -1, _IO_P1_AI_01
MDF = 1\1, 0, 0, 2, -1, _IO_P1_AI_02
MDF = 1\1, 0, 0, 3, -1, _IO_P1_AI_03
[__READONLY_VALUES]

Binary file not shown.

View File

@@ -1,2 +1,2 @@
[RMDManager]
TASK=REBUILD
TASK=BUILD

Binary file not shown.

Binary file not shown.

BIN
IPP-PLC.zip Normal file

Binary file not shown.

10
IPP-PLC/ConfigMeFirst.txt Normal file
View File

@@ -0,0 +1,10 @@
# ConfigMeFirst for Henry Pump Intelligent Pump Panel
# Written by Patrick McDonagh, Henry Pump
#
[PM] # Force Program Mode
[CF] # Clear any faults on the controller
[IPA=192.168.1.5] # Sets IP Address
[SNM=255.255.255.0] # Sets Subnet Mask
[GWA=192.168.1.1] # Sets Default Gateway
[RSD=IPP]
[END]

Binary file not shown.

Binary file not shown.

Binary file not shown.

Binary file not shown.

Binary file not shown.

Binary file not shown.

BIN
IPP-PLC/IPP/USERPRJ/M800ID Normal file

Binary file not shown.

Binary file not shown.

BIN
IPP-PLC/IPP/USERPRJ/RA00 Normal file

Binary file not shown.

0
IPP-PLC/IPP/USERPRJ/RA01 Normal file
View File

BIN
IPP-PLC/IPP/USERPRJ/RA02 Normal file

Binary file not shown.

BIN
IPP-PLC/IPP/USERPRJ/RA03 Normal file

Binary file not shown.

BIN
IPP-PLC/IPP/USERPRJ/RA04 Normal file

Binary file not shown.

BIN
IPP-PLC/IPP/USERPRJ/RA05 Normal file

Binary file not shown.

BIN
IPP-PLC/IPP/USERPRJ/RA06 Normal file

Binary file not shown.

BIN
IPP-PLC/IPP/USERPRJ/RA07 Normal file

Binary file not shown.

BIN
IPP-PLC/IPP/USERPRJ/RA08 Normal file

Binary file not shown.

BIN
IPP-PLC/IPP/USERPRJ/RA09 Normal file

Binary file not shown.

BIN
IPP-PLC/IPP/USERPRJ/RA10 Normal file

Binary file not shown.

BIN
IPP-PLC/IPP/USERPRJ/RA11 Normal file

Binary file not shown.

0
IPP-PLC/IPP/USERPRJ/RA12 Normal file
View File

BIN
IPP-PLC/IPP/USERPRJ/RA13 Normal file

Binary file not shown.

Some files were not shown because too many files have changed in this diff Show More