# Integer Status Mappings ## Device Status | Integer | String | |---------- | --------------------------------- | | 0 | Unknown | | 1 | Startup | | 2 | Not Ready to Start | | 3 | Lost Run Permissive | | 4 | Running | | 5 | Contactor Failure, Recovering | | 6 | Waiting to attempt restart | | 7 | Waiting to restart after overload | | 8 | User stopped | ## Downhole Tool Status | Integer | String | |---------- | --------------------------------- | | 0 | OK | | 1 | Connecting | | 2 | Open Circuit | | 3 | Shorted | | 4 | Cannot Decode | | 5 | Unknown | | 6 | Disabled | ## HOA Status | Integer | String | |---------- | --------------------------------- | | 0 | Auto | | 1 | Hand | | 2 | Off | ## UPS Status | Integer | String | |---------- | --------------------------------- | | 0 | Ready | | 1 | Charging | | 2 | Active | | 3 | Bad Battery | ## Current Trip/Warning Status | Integer | String | |---------- | --------------------------------- | | -1 | OK | | 0 | Overload | | 1 | Phase Loss | | 2 | Ground Fault | | 3 | Stall | | 4 | Jam | | 5 | Underload | | 6 | Current Imbalance | | 7 | L1 Undercurrent | | 8 | L2 Undercurrent | | 9 | L3 Undercurrent | | 10 | L1 Overcurrent | | 11 | L2 Overcurrent | | 12 | L3 Overcurrent | | 13 | L1 Line Loss | | 14 | L2 Line Loss | | 15 | L3 Line Loss | ## Voltage Trip/Warning Status | Integer | String | |---------- | --------------------------------- | | -1 | OK | | 0 | Undervoltage | | 1 | Overvoltage | | 2 | Voltage Imbalance | | 3 | Phase Rotation | | 4 | Underfrequency | | 5 | Overfrequency | ## Control Trip/Warning Status | Integer | String | |---------- | --------------------------------- | | -1 | Test | | 0 | PTC | | 1 | DeviceLogix | | 2 | Operator Station | | 3 | Remote | | 4 | Blocked Start | | 5 | Hardware Fault | | 6 | Config | | 7 | Option Match | | 8 | DeviceLogix FB Timeout | | 9 | Expansion Bus | | 10 | Reserved | | 11 | Reserved | | 12 | Non-Volatile Storage | | 13 | Test Mode | ## Power Trip/Warning Status | Integer | String | |---------- | --------------------------------- | | -1 | OK | | 0 | Under kW | | 1 | Over kW | | 2 | Under kVAR Consumed | | 3 | Over kVAR Consumed | | 4 | Under kVAR Generated | | 5 | Over kVAR Generated | | 6 | Under kVA | | 7 | Over kVA | | 8 | Under PF Lagging | | 9 | Over PF Lagging | | 10 | Under PF Leading | | 11 | Over PF Leading | ## Overall Device Status | Integer | String | |---------- | --------------------------------- | | 0 | Running | | 1 | HOA in Off | | 2 | Remote Stop | | 3 | Local Stop | | 4 | Timer Stop | | 5 | Downhole Pressure | | 6 | Downhole Temperature | | 7 | Tubing Pressure | | 8 | Low Flow | | 9 | Current: Overload | | 10 | Current: Phase Loss | | 11 | Current: Ground Fault | | 12 | Current: Stall | | 13 | Current: Jam | | 14 | Current: Underload | | 15 | Current: Current Imbalance | | 16 | Current: L1 Undercurrent | | 17 | Current: L2 Undercurrent | | 18 | Current: L3 Undercurrent | | 19 | Current: L1 Overcurrent | | 20 | Current: L2 Overcurrent | | 21 | Current: L3 Overcurrent | | 22 | Current: L1 Line Loss | | 23 | Current: L2 Line Loss | | 24 | Current: L3 Line Loss | | 25 | Voltage: Undervoltage | | 26 | Voltage: Overvoltage | | 27 | Voltage: Voltage Imbalance | | 28 | Voltage: Phase Rotation | | 29 | Voltage: Underfrequency | | 30 | Voltage: Overfrequency | | 31 | E300 Hardware Fault | | 32 | E300 Config | | 33 | E300 Option Match | | 34 | E300 Non-Volatile Storage | | 35 | Power: Under kW | | 36 | Power: Over kW | | 37 | Power: Under kVAR Consumed | | 38 | Power: Over kVAR Consumed | | 39 | Power: Under kVAR Generated | | 40 | Power: Over kVAR Generated | | 41 | Power: Under kVA | | 42 | Power: Over kVA | | 43 | Power: Under PF Lagging | | 44 | Power: Over PF Lagging | | 45 | Power: Under PF Leading | | 46 | Power: Over PF Leading |