Commit Graph

36 Commits

Author SHA1 Message Date
Patrick McDonagh
fbd2b41b52 Moves cfg_Flowmeter type to Controller Scope 2017-04-03 16:02:58 -05:00
Patrick McDonagh
a358501870 Updated to add modbus flowmeter logic 2017-03-29 12:46:23 -05:00
Patrick McDonagh
bc60b1ce48 Fixes a few graphics issues 2016-10-17 17:19:25 -05:00
Patrick McDonagh
79a6ad4ec5 Updated files and added files for automatic configuration of PLC and HMI 2016-09-15 16:54:43 -05:00
Patrick McDonagh
d43d4ebc30 Fixes Tubing Pressure Start Permissive text overflow and missing animation 2016-09-13 13:12:03 -05:00
Patrick McDonagh
1b917792b2 Completes IPP-145. Device will show indication of Tubing Pressure holding out start when pressure switch is tripped 2016-09-09 14:49:26 -05:00
Patrick McDonagh
94204c1958 Fixes Pioneer IPP-125, IPP-126, IPP-127, IPP-128 2016-08-17 17:03:43 -05:00
Patrick McDonagh
6e03647d38 Completes IPP-110, IPP-111, IPP-112. Display for %FLA, Fix for not reading Frequency or Phase Rotation 2016-08-10 19:22:30 -05:00
Patrick McDonagh
ae150eb329 Updates IP Address in HMI program for behind NAT 2016-08-10 14:03:19 -05:00
Patrick McDonagh
6eb942c83c Completes IPP-108, adding 30 second delay timer for High Pressure Switch 2016-08-10 11:59:08 -05:00
Patrick McDonagh
f340a0d4db Adds HMI Alarms for Surface Pressure and Flow, Adds Overall Trip Status to main screen 2016-08-09 08:24:15 -05:00
Patrick McDonagh
58f38aae0f Configured Alarm Setpoints before installing first panel 2016-08-08 09:57:36 -05:00
Patrick McDonagh
4b9ccd6b76 Completes IPP-55. Adds ability to reset E300 to defaults 2016-07-26 17:10:06 -05:00
Patrick McDonagh
67af129c36 Completes IPP-96, adds Phase Rotation Trip logic 2016-07-26 15:50:18 -05:00
Patrick McDonagh
edab6e07f9 Completes IPP-76, Lightning arrestor to be wired to digital input 7, assumed to be N.C. 2016-07-25 18:36:16 -05:00
Patrick McDonagh
f1ccc3fca1 Fixes IPP-72, Adds watchdog timeout for datalogger. uses tag Datalogger_Watchdog_Timeout 2016-07-25 16:36:24 -05:00
Patrick McDonagh
8640c52565 Completes IPP-71, Alarms on UPS errors. UPS Ready = Digital In 4, UPS Buffering = Digital In 5, UPS Replace Battery = Digital In 6 2016-07-25 15:03:28 -05:00
Patrick McDonagh
79fe78e67c Completes IPP-83, configuration and calculation for fluid level 2016-07-25 14:32:58 -05:00
Patrick McDonagh
42f62a334e PLC and HMI Programming for IPP-70, adding Tubing Pressure Switch (and disable button) wired into digital input 3 2016-07-25 14:24:15 -05:00
Patrick McDonagh
feac0be9a6 File Cleanup 2016-07-13 08:03:25 -05:00
Patrick McDonagh
eac3378fec Fixes IPP-60. Fixes Low Tubing Pressure SP 2016-07-11 21:20:14 -05:00
Patrick McDonagh
87eace08dd Adds IPP-58, ability to configure flow and pressure alarms on HMI 2016-07-11 17:49:36 -05:00
Patrick McDonagh
d494ee0ac3 Fixes IPP-57. Since we'll always have tubing pressure, removed the tag completely 2016-07-11 15:52:45 -05:00
Patrick McDonagh
9d4cf67a7f Fixes IPP-56. Removed WarningEnable tag for Phase Loss 2016-07-11 15:33:03 -05:00
Patrick McDonagh
0b1f96e458 Completes IPP-51. Adds Flow to Downhole screen of the HMI 2016-06-17 10:43:52 -05:00
Patrick McDonagh
d915e96e18 Fixes IPP-30. When parameters are written to the E300, it gets inhibited and then uninhibited 2016-05-12 23:49:31 -05:00
Patrick McDonagh
3d31144766 removed that pesky .ccwsuo file from tracking 2016-04-15 14:28:47 -05:00
Patrick McDonagh
496c6d80c3 Fixed trends not holding enough data for full screen 2016-04-11 14:35:17 -05:00
Patrick McDonagh
b2ab02555f Added ability to disable E300 and use local IO for retrofits 2016-04-06 16:15:13 -05:00
Patrick McDonagh
55d96766f5 Added missing E300 parameters that aren't included in Add-On Profile 2016-02-18 19:24:52 -06:00
Patrick McDonagh
6532c6dbbd Fixed current screen navigation and enable tags 2016-02-16 16:53:53 -06:00
Patrick McDonagh
380b4936be Made changes to get the panel up and running 2016-02-16 16:28:47 -06:00
Patrick McDonagh
9b11212ec0 Updated PLC address 2016-02-16 13:00:44 -06:00
Patrick McDonagh
999f8cdb64 Combined TCU and FLA screens 2016-02-16 08:41:42 -06:00
Patrick McDonagh
843b7ad18e Deleted screens to make application fit for compactlogix
1. OverFrequency
2. Underfrequency
3. Voltage Imbalance
4. CT
5. PT
6. Voltage Mode
7. Underload
8. Undercurrent 
9. Phase Rotation
10. Power
11. IO
12. Current Imbalance
2016-02-15 07:43:29 -06:00
Patrick McDonagh
c548223066 Initial Commit 2016-02-12 17:48:23 -06:00