updates
This commit is contained in:
@@ -2,24 +2,24 @@ from Channel import PLCChannel, ModbusChannel
|
||||
from dual_flowmeter import PLC_IP_ADDRESS
|
||||
|
||||
tags = [
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_daily_total","Pump_1_Daily_Flow_Rate_Total","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_daily_total","Pump_1_Daily_Flow_Rate_Total","REAL", 100, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_run_status","Pump_1_Run_Status","BOOL", 0, 3600, plc_type="Micro800", map_={0: "Off", 1: "On"}),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_flowrate","Pump_1_SCL_Flow_Meter","REAL", 250, 600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_yesterdays_total","Pump_1_Yesterdays_Total","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_power","Pump_1_Power","BOOL", 0, 3600, plc_type="Micro800", map_={0: "Off", 1: "On"}),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_prevmonth_total","Pump_1_PrevMonth_Total","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_month_total","Pump_1_Current_Month_Total","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_lifetime_total","Pump_1_Lifetime_Flow","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_flowrate","Pump_1_SCL_Flow_Meter","REAL", 1000, 600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_yesterdays_total","Pump_1_Yesterdays_Total","REAL", 1000, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_prevmonth_total","Pump_1_PrevMonth_Total","REAL", 1000, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_month_total","Pump_1_Current_Month_Total","REAL", 1000, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_lifetime_total","Pump_1_Lifetime_Flow","REAL", 1000, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_1_suction","Suction_PSI_TP1_Scaled","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_daily_total","Pump_2_Daily_Flow_Rate_Total","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_daily_total","Pump_2_Daily_Flow_Rate_Total","REAL", 100, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_run_status","Pump_2_Run_Status","BOOL", 0, 3600, plc_type="Micro800", map_={0: "Off", 1: "On"}),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_flowrate","Pump_2_SCL_Flow_Meter","REAL", 250, 600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_yesterdays_total","Pump_2_Yesterdays_Total","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_power","Pump_2_Power","BOOL", 0, 3600, plc_type="Micro800", map_={0: "Off", 1: "On"}),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_prevmonth_total","Pump_2_PrevMonth_Total","REAL", 100, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_month_total","Pump_2_Current_Month_Total","REAL", 50, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_lifetime_total","Pump_2_Lifetime_Flow","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_flowrate","Pump_2_SCL_Flow_Meter","REAL", 1000, 600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_yesterdays_total","Pump_2_Yesterdays_Total","REAL", 1000, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_prevmonth_total","Pump_2_PrevMonth_Total","REAL", 1000, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_month_total","Pump_2_Current_Month_Total","REAL", 1000, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_lifetime_total","Pump_2_Lifetime_Flow","REAL", 1000, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_2_suction","Suction_PSI_TP2_Scaled","REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pump_charge_psi_tp1", "Charge_PSI_TP1_Scaled", "REAL", 10, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pond_1_height", "Pond_level_tp1_scaled", "REAL", 2, 3600, plc_type="Micro800")
|
||||
PLCChannel(PLC_IP_ADDRESS, "pond_1_height", "Pond_level_tp1_scaled", "REAL", 2, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pond_1_volume", "pond1volume", "REAL", 100000, 3600, plc_type="Micro800"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "charge_pump_run_status","CHARGE_PUMP_Run_Status","BOOL", 0, 3600, plc_type="Micro800", map_={0: "Off", 1: "On"})
|
||||
]
|
||||
@@ -8,7 +8,7 @@
|
||||
"file4": "Tags.py"
|
||||
},
|
||||
"deviceName": "dual_flowmeter",
|
||||
"releaseVersion": "5",
|
||||
"releaseVersion": "7",
|
||||
"driverFileName": "dual_flowmeter.py",
|
||||
"driverId": "0100"
|
||||
}
|
||||
@@ -10,7 +10,7 @@ from Channel import PLCChannel, ModbusChannel,read_tag, write_tag, TAG_DATAERROR
|
||||
import persistence
|
||||
from utilities import get_public_ip_address
|
||||
from file_logger import filelogger as log
|
||||
PLC_IP_ADDRESS = "192.168.1.10"
|
||||
PLC_IP_ADDRESS = "192.168.1.12"
|
||||
from Tags import tags
|
||||
|
||||
_ = None
|
||||
@@ -42,7 +42,7 @@ class start(threading.Thread, deviceBase):
|
||||
mqtt=mqtt, Nodes=Nodes)
|
||||
|
||||
self.daemon = True
|
||||
self.version = "5"
|
||||
self.version = "7"
|
||||
self.finished = threading.Event()
|
||||
self.force_send = False
|
||||
self.public_ip_address = ""
|
||||
|
||||