Added Folders

Add all the driver folders
This commit is contained in:
2019-12-13 12:15:30 -06:00
parent 7ea92c19f6
commit 632dcdb3e8
226 changed files with 54771 additions and 0 deletions

149
advvfdipp/Channel.py Normal file
View File

@@ -0,0 +1,149 @@
"""Define Meshify channel class."""
from pycomm.ab_comm.clx import Driver as ClxDriver
from pycomm.cip.cip_base import CommError, DataError
import time
def read_tag(addr, tag):
"""Read a tag from the PLC."""
c = ClxDriver()
try:
if c.open(addr):
try:
v = c.read_tag(tag)
return v
except DataError:
c.close()
print("Data Error during readTag({}, {})".format(addr, tag))
except CommError:
# err = c.get_status()
c.close()
print("Could not connect during readTag({}, {})".format(addr, tag))
# print err
except AttributeError as e:
c.close()
print("AttributeError during readTag({}, {}): \n{}".format(addr, tag, e))
c.close()
return False
def read_array(addr, tag, start, end):
"""Read an array from the PLC."""
c = ClxDriver()
if c.open(addr):
arr_vals = []
try:
for i in range(start, end):
tag_w_index = tag + "[{}]".format(i)
v = c.read_tag(tag_w_index)
# print('{} - {}'.format(tag_w_index, v))
arr_vals.append(round(v[0], 4))
# print(v)
if len(arr_vals) > 0:
return arr_vals
else:
print("No length for {}".format(addr))
return False
except Exception:
print("Error during readArray({}, {}, {}, {})".format(addr, tag, start, end))
err = c.get_status()
c.close()
print err
pass
c.close()
def write_tag(addr, tag, val):
"""Write a tag value to the PLC."""
c = ClxDriver()
if c.open(addr):
try:
cv = c.read_tag(tag)
wt = c.write_tag(tag, val, cv[1])
return wt
except Exception:
print("Error during writeTag({}, {}, {})".format(addr, tag, val))
err = c.get_status()
c.close()
print err
c.close()
class Channel:
"""Holds the configuration for a Meshify channel."""
def __init__(self, ip, mesh_name, plc_tag, data_type, chg_threshold, guarantee_sec, map_=False, write_enabled=False):
"""Initialize the channel."""
self.plc_ip = ip
self.mesh_name = mesh_name
self.plc_tag = plc_tag
self.data_type = data_type
self.last_value = None
self.value = None
self.last_send_time = 0
self.chg_threshold = chg_threshold
self.guarantee_sec = guarantee_sec
self.map_ = map_
self.write_enabled = write_enabled
def __str__(self):
"""Create a string for the channel."""
return "{}: {}\nvalue: {}, last_send_time: {}".format(self.mesh_name, self.plc_tag, self.value, self.last_send_time)
def read(self, force_send=False):
"""Read the value and check to see if needs to be stored."""
send_needed = False
send_reason = ""
if self.plc_tag:
v = read_tag(self.plc_ip, self.plc_tag)
if v:
if self.data_type == 'BOOL' or self.data_type == 'STRING':
if self.last_send_time == 0:
send_needed = True
send_reason = "no send time"
elif self.value is None:
send_needed = True
send_reason = "no value"
elif not (self.value == v[0]):
if self.map_:
if not self.value == self.map_[v[0]]:
send_needed = True
send_reason = "value change"
else:
send_needed = True
send_reason = "value change"
elif (time.time() - self.last_send_time) > self.guarantee_sec:
send_needed = True
send_reason = "guarantee sec"
elif force_send:
send_needed = True
send_reason = "forced"
else:
if self.last_send_time == 0:
send_needed = True
send_reason = "no send time"
elif self.value is None:
send_needed = True
send_reason = "no value"
elif abs(self.value - v[0]) > self.chg_threshold:
send_needed = True
send_reason = "change threshold"
elif (time.time() - self.last_send_time) > self.guarantee_sec:
send_needed = True
send_reason = "guarantee sec"
elif force_send:
send_needed = True
send_reason = "forced"
if send_needed:
self.last_value = self.value
if self.map_:
try:
self.value = self.map_[v[0]]
except KeyError:
print("Cannot find a map value for {} in {} for {}".format(v[0], self.map_, self.mesh_name))
self.value = v[0]
else:
self.value = v[0]
self.last_send_time = time.time()
print("Sending {} for {} - {}".format(self.value, self.mesh_name, send_reason))
return send_needed

116
advvfdipp/advvfdipp.py Normal file
View File

@@ -0,0 +1,116 @@
"""Max Water System driver code."""
import threading
import sys
import logging
import time
from random import randint
from Channel import write_tag, read_tag
from device_base import deviceBase
from utilities import get_public_ip_address
import json
# LOGGING SETUP
from logging.handlers import RotatingFileHandler
log_formatter = logging.Formatter('%(asctime)s %(levelname)s %(funcName)s(%(lineno)d) %(message)s')
logFile = './advvfdipp.log'
my_handler = RotatingFileHandler(logFile, mode='a', maxBytes=500*1024, backupCount=2, encoding=None, delay=0)
my_handler.setFormatter(log_formatter)
my_handler.setLevel(logging.INFO)
logger = logging.getLogger('advvfdipp')
logger.setLevel(logging.INFO)
logger.addHandler(my_handler)
console_out = logging.StreamHandler(sys.stdout)
console_out.setFormatter(log_formatter)
logger.addHandler(console_out)
logger.info("advvfdipp startup")
PLC_IP_ADDRESS = "192.168.1.10"
WATCHDOG_SEND_PERIOD = 3600 # seconds
class start(threading.Thread, deviceBase):
"""Driver class."""
def __init__(self, name=None, number=None, mac=None, Q=None, mcu=None, companyId=None, offset=None, mqtt=None, Nodes=None):
"""Initialize the driver."""
threading.Thread.__init__(self)
deviceBase.__init__(self, name=name, number=number, mac=mac, Q=Q, mcu=mcu, companyId=companyId, offset=offset, mqtt=mqtt, Nodes=Nodes)
self.daemon = True
self.version = "9"
self.finished = threading.Event()
threading.Thread.start(self)
def register(self):
"""Required function for all drivers, its goal is to upload some piece of data about your device so it can be seen on the web."""
self.channels["status"]["last_value"] = ""
def run(self):
"""Run the driver."""
wait_sec = 30
for i in range(0, wait_sec):
print("advvfdipp driver will start in {} seconds".format(wait_sec - i))
time.sleep(1)
logger.info("BOOM! Starting advvfdipp driver...")
self.nodes["advvfdipp_0199"] = self
public_ip_address = get_public_ip_address()
self.sendtodbDev(1, 'public_ip_address', public_ip_address, 0, 'advvfdipp')
watchdog = self.advvfdipp_watchdog()
self.sendtodbDev(1, 'watchdog', watchdog, 0, 'advvfdipp')
watchdog_send_timestamp = time.time()
watchdog_loops = 0
watchdog_check_after = 5000
while True:
self.nodes["advvfdipp_0199"] = self
watchdog_loops += 1
if (watchdog_loops >= watchdog_check_after):
test_watchdog = self.advvfdipp_watchdog()
if not test_watchdog == watchdog or (time.time() - watchdog_send_timestamp) > WATCHDOG_SEND_PERIOD:
self.sendtodbDev(1, 'watchdog', test_watchdog, 0, 'advvfdipp')
watchdog = test_watchdog
test_public_ip = get_public_ip_address()
if not test_public_ip == public_ip_address:
self.sendtodbDev(1, 'public_ip_address', test_public_ip, 0, 'advvfdipp')
public_ip_address = test_public_ip
watchdog_loops = 0
time.sleep(15)
def advvfdipp_watchdog(self):
"""Write a random integer to the PLC and then 1 seconds later check that it has been decremented by 1."""
randval = randint(0, 32767)
write_tag(str(PLC_IP_ADDRESS), 'watchdog_INT', randval)
time.sleep(1)
watchdog_val = read_tag(str(PLC_IP_ADDRESS), 'watchdog_INT')
try:
return (randval - 1) == watchdog_val[0]
except (KeyError, TypeError):
return False
def advvfdipp_sync(self, name, value):
"""Sync all data from the driver."""
self.forceSend = True
# self.sendtodb("log", "synced", 0)
return True
def advvfdipp_writeplctag(self, name, value):
"""Write a value to the PLC."""
try:
new_val = json.loads(str(value).replace("'", '"'))
tag_n = str(new_val['tag']) # "cmd_Start"
val_n = new_val['val']
w = write_tag(str(PLC_IP_ADDRESS), tag_n, val_n)
logger.warning("Result of advvfdipp_writeplctag(self, {}, {}) = {}".format(name, value, w))
if w is None:
w = "Error writing to PLC..."
return w
except Exception as e:
logger.warning("GOT EXCEPTION in advvfdipp_writeplctag(self, {}, {}) => {}".format(name, value, e))
return e

View File

@@ -0,0 +1,298 @@
"""Define Meshify channel class."""
import time
import urllib
from pycomm.ab_comm.clx import Driver as ClxDriver
from pycomm.cip.cip_base import CommError, DataError
from file_logger import filelogger as log
TAG_DATAERROR_SLEEPTIME = 5
def binarray(intval):
"""Split an integer into its bits."""
bin_string = '{0:08b}'.format(intval)
bin_arr = [i for i in bin_string]
bin_arr.reverse()
return bin_arr
def read_tag(addr, tag, plc_type="CLX"):
"""Read a tag from the PLC."""
direct = plc_type == "Micro800"
clx = ClxDriver()
try:
if clx.open(addr, direct_connection=direct):
try:
val = clx.read_tag(tag)
clx.close()
return val
except DataError as err:
clx.close()
time.sleep(TAG_DATAERROR_SLEEPTIME)
log.error("Data Error during readTag({}, {}): {}".format(addr, tag, err))
except CommError:
# err = c.get_status()
clx.close()
log.error("Could not connect during readTag({}, {})".format(addr, tag))
except AttributeError as err:
clx.close()
log.error("AttributeError during readTag({}, {}): \n{}".format(addr, tag, err))
clx.close()
return False
def read_array(addr, tag, start, end, plc_type="CLX"):
"""Read an array from the PLC."""
direct = plc_type == "Micro800"
clx = ClxDriver()
if clx.open(addr, direct_connection=direct):
arr_vals = []
try:
for i in range(start, end):
tag_w_index = tag + "[{}]".format(i)
val = clx.read_tag(tag_w_index)
arr_vals.append(round(val[0], 4))
if arr_vals:
clx.close()
return arr_vals
else:
log.error("No length for {}".format(addr))
clx.close()
return False
except Exception:
log.error("Error during readArray({}, {}, {}, {})".format(addr, tag, start, end))
err = clx.get_status()
clx.close()
log.error(err)
clx.close()
def write_tag(addr, tag, val, plc_type="CLX"):
"""Write a tag value to the PLC."""
direct = plc_type == "Micro800"
clx = ClxDriver()
try:
if clx.open(addr, direct_connection=direct):
try:
initial_val = clx.read_tag(tag)
write_status = clx.write_tag(tag, val, initial_val[1])
clx.close()
return write_status
except DataError as err:
clx_err = clx.get_status()
clx.close()
log.error("--\nDataError during writeTag({}, {}, {}, plc_type={}) -- {}\n{}\n".format(addr, tag, val, plc_type, err, clx_err))
except CommError as err:
clx_err = clx.get_status()
log.error("--\nCommError during write_tag({}, {}, {}, plc_type={})\n{}\n--".format(addr, tag, val, plc_type, err))
clx.close()
return False
class Channel(object):
"""Holds the configuration for a Meshify channel."""
def __init__(self, mesh_name, data_type, chg_threshold, guarantee_sec, map_=False, write_enabled=False):
"""Initialize the channel."""
self.mesh_name = mesh_name
self.data_type = data_type
self.last_value = None
self.value = None
self.last_send_time = 0
self.chg_threshold = chg_threshold
self.guarantee_sec = guarantee_sec
self.map_ = map_
self.write_enabled = write_enabled
def __str__(self):
"""Create a string for the channel."""
return "{}\nvalue: {}, last_send_time: {}".format(self.mesh_name, self.value, self.last_send_time)
def check(self, new_value, force_send=False):
"""Check to see if the new_value needs to be stored."""
send_needed = False
send_reason = ""
if self.data_type == 'BOOL' or self.data_type == 'STRING':
if self.last_send_time == 0:
send_needed = True
send_reason = "no send time"
elif self.value is None:
send_needed = True
send_reason = "no value"
elif self.value != new_value:
if self.map_:
if not self.value == self.map_[new_value]:
send_needed = True
send_reason = "value change"
else:
send_needed = True
send_reason = "value change"
elif (time.time() - self.last_send_time) > self.guarantee_sec:
send_needed = True
send_reason = "guarantee sec"
elif force_send:
send_needed = True
send_reason = "forced"
else:
if self.last_send_time == 0:
send_needed = True
send_reason = "no send time"
elif self.value is None:
send_needed = True
send_reason = "no value"
elif abs(self.value - new_value) > self.chg_threshold:
send_needed = True
send_reason = "change threshold"
elif (time.time() - self.last_send_time) > self.guarantee_sec:
send_needed = True
send_reason = "guarantee sec"
elif force_send:
send_needed = True
send_reason = "forced"
if send_needed:
self.last_value = self.value
if self.map_:
try:
self.value = self.map_[new_value]
except KeyError:
log.error("Cannot find a map value for {} in {} for {}".format(new_value, self.map_, self.mesh_name))
self.value = new_value
else:
self.value = new_value
self.last_send_time = time.time()
log.info("Sending {} for {} - {}".format(self.value, self.mesh_name, send_reason))
return send_needed
def read(self):
"""Read the value."""
pass
def identity(sent):
"""Return exactly what was sent to it."""
return sent
class ModbusChannel(Channel):
"""Modbus channel object."""
def __init__(self, mesh_name, register_number, data_type, chg_threshold, guarantee_sec, channel_size=1, map_=False, write_enabled=False, transform_fn=identity):
"""Initialize the channel."""
super(ModbusChannel, self).__init__(mesh_name, data_type, chg_threshold, guarantee_sec, map_, write_enabled)
self.mesh_name = mesh_name
self.register_number = register_number
self.channel_size = channel_size
self.data_type = data_type
self.last_value = None
self.value = None
self.last_send_time = 0
self.chg_threshold = chg_threshold
self.guarantee_sec = guarantee_sec
self.map_ = map_
self.write_enabled = write_enabled
self.transform_fn = transform_fn
def read(self, mbsvalue):
"""Return the transformed read value."""
return self.transform_fn(mbsvalue)
class PLCChannel(Channel):
"""PLC Channel Object."""
def __init__(self, ip, mesh_name, plc_tag, data_type, chg_threshold, guarantee_sec, map_=False, write_enabled=False, plc_type='CLX'):
"""Initialize the channel."""
super(PLCChannel, self).__init__(mesh_name, data_type, chg_threshold, guarantee_sec, map_, write_enabled)
self.plc_ip = ip
self.mesh_name = mesh_name
self.plc_tag = plc_tag
self.data_type = data_type
self.last_value = None
self.value = None
self.last_send_time = 0
self.chg_threshold = chg_threshold
self.guarantee_sec = guarantee_sec
self.map_ = map_
self.write_enabled = write_enabled
self.plc_type = plc_type
def read(self):
"""Read the value."""
plc_value = None
if self.plc_tag and self.plc_ip:
read_value = read_tag(self.plc_ip, self.plc_tag, plc_type=self.plc_type)
if read_value:
plc_value = read_value[0]
return plc_value
class BoolArrayChannels(Channel):
"""Hold the configuration for a set of boolean array channels."""
def __init__(self, ip, mesh_name, plc_tag, data_type, chg_threshold, guarantee_sec, map_=False, write_enabled=False):
"""Initialize the channel."""
super(BoolArrayChannels, self).__init__(mesh_name, data_type, chg_threshold, guarantee_sec, map_, write_enabled)
self.plc_ip = ip
self.mesh_name = mesh_name
self.plc_tag = plc_tag
self.data_type = data_type
self.last_value = None
self.value = None
self.last_send_time = 0
self.chg_threshold = chg_threshold
self.guarantee_sec = guarantee_sec
self.map_ = map_
self.write_enabled = write_enabled
def compare_values(self, new_val_dict):
"""Compare new values to old values to see if the values need storing."""
send = False
for idx in new_val_dict:
try:
if new_val_dict[idx] != self.last_value[idx]:
send = True
except KeyError:
log.error("Key Error in self.compare_values for index {}".format(idx))
send = True
return send
def read(self, force_send=False):
"""Read the value and check to see if needs to be stored."""
send_needed = False
send_reason = ""
if self.plc_tag:
val = read_tag(self.plc_ip, self.plc_tag)
if val:
bool_arr = binarray(val[0])
new_val = {}
for idx in self.map_:
try:
new_val[self.map_[idx]] = bool_arr[idx]
except KeyError:
log.error("Not able to get value for index {}".format(idx))
if self.last_send_time == 0:
send_needed = True
send_reason = "no send time"
elif self.value is None:
send_needed = True
send_reason = "no value"
elif self.compare_values(new_val):
send_needed = True
send_reason = "value change"
elif (time.time() - self.last_send_time) > self.guarantee_sec:
send_needed = True
send_reason = "guarantee sec"
elif force_send:
send_needed = True
send_reason = "forced"
if send_needed:
self.value = new_val
self.last_value = self.value
self.last_send_time = time.time()
log.info("Sending {} for {} - {}".format(self.value, self.mesh_name, send_reason))
return send_needed

View File

@@ -0,0 +1,49 @@
from Channel import PLCChannel, ModbusChannel
from advvfdipp import PLC_IP_ADDRESS
tags = [
PLCChannel(PLC_IP_ADDRESS, "flowrate","val_Flowmeter","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "fluidlevel","val_FluidLevel","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "intakepressure","val_IntakePressure","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "intaketemperature","val_IntakeTemperature","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "tubingpressure","val_TubingPressure","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "pidcontrolmode","sts_PID_Control","BOOL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "wellstatus","Device_Status_INT","INT", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "vfdfrequency","VFD_SpeedFdbk","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "flowtotal","Flow_Total[0]","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "energytotal","Energy_Total[0]","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "vfdcurrent","VFD_OutCurrent","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "downholesensorstatus","Downhole_Sensor_Status_INT","INT", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "fluidspecificgravity","cfg_FluidSpecificGravity","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "flowtotalyesterday","Flow_Total[1]","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "energytotalyesterday","Energy_Total[1]","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "alarmflowrate","alarm_Flowmeter","BOOL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "alarmintakepressure","alarm_IntakePressure","BOOL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "alarmintaketemperature","alarm_IntakeTemperature","BOOL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "alarmtubingpressure","alarm_TubingPressure","BOOL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "alarmvfd","alarm_VFD","BOOL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "alarmlockout","alarm_Lockout","BOOL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "runpermissive","Run_Permissive_INT","INT", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "startpermissive","Start_Permissive_INT","INT", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "startcommand","cmd_Start","BOOL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "stopcommand","cmd_Stop","BOOL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "flowsetpoint","cfg_PID_FlowSP","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "fluidlevelsetpoint","cfg_PID_FluidLevelSP","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "manualfrequencysetpoint","cfg_PID_ManualSP","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "tubingpressuresetpoint","cfg_PID_TubingPressureSP","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "alarmfluidlevel","alarm_FluidLevel","BOOL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "pressureshutdownlimit","AIn_IntakePressure.Val_LoLim","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "pressurestartuplimit","AIn_IntakePressure.Val_HiLim","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "temperatureshutdownlimit","AIn_IntakeTemperature.Val_HiLim","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "temperaturestartuplimit","AIn_IntakeTemperature.Val_LoLim","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "sensorheight","cfg_DHSensorDistToIntake","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "last_vfd_fault_code","PowerFlex755.Val_LastFaultCode","INT", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "vfd_fault","sts_CurrentVFDFaultCode","INT", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "controllerfault_io","ControllerFault_IO","BOOL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "controllerfault_program","ControllerFault_Program","BOOL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "minvfdfrequency","PowerFlex755.Cfg_MinSpdRef","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "maxvfdfrequency","PowerFlex755.Cfg_MaxSpdRef","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "hartnettotal","in_HART_Flowmeter_Net","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "hartfwdtotal","in_HART_Flowmeter_Fwd","REAL", 1, 3600, plc_type="CLX"),
PLCChannel(PLC_IP_ADDRESS, "hartrevtotal","in_HART_Flowmeter_Rev","REAL", 1, 3600, plc_type="CLX")
]

View File

@@ -0,0 +1,200 @@
"""Driver for advvfdipp"""
import threading
import json
import time
from random import randint
# PERSISTENCE FILE
import persistence
PERSIST = persistence.load("extra_data.json")
if not PERSIST:
PERSIST = {'ip_address': '192.168.1.10', 'download_pycomm': True}
persistence.store(PERSIST, "extra_data.json")
PLC_IP_ADDRESS = PERSIST['ip_address']
from device_base import deviceBase
from Channel import PLCChannel, ModbusChannel,read_tag, write_tag, TAG_DATAERROR_SLEEPTIME
from utilities import get_public_ip_address, get_additional_tags, convert_int
from file_logger import filelogger as log
from Tags import tags
import os
import urllib
path = "/root/python_firmware/drivers/additional_tags.py"
f = open(path, "a+")
f.seek(0)
if os.stat(path).st_size == 0:
f.write("from Channel import PLCChannel, ModbusChannel\n")
f.write("from advvfdipp import PLC_IP_ADDRESS\n")
f.write("additional_tags = []")
f.close()
from additional_tags import additional_tags
_ = None
log.info("advvfdipp startup")
# GLOBAL VARIABLES
WAIT_FOR_CONNECTION_SECONDS = 60
IP_CHECK_PERIOD = 60
WATCHDOG_ENABLE = False
WATCHDOG_CHECK_PERIOD = 60
WATCHDOG_SEND_PERIOD = 3600 # Seconds, the longest amount of time before sending the watchdog status
CHANNELS = tags + additional_tags
class start(threading.Thread, deviceBase):
"""Start class required by Meshify."""
def __init__(self, name=None, number=None, mac=None, Q=None, mcu=None,
companyId=None, offset=None, mqtt=None, Nodes=None):
"""Initialize the driver."""
threading.Thread.__init__(self)
deviceBase.__init__(self, name=name, number=number, mac=mac, Q=Q,
mcu=mcu, companyId=companyId, offset=offset,
mqtt=mqtt, Nodes=Nodes)
self.daemon = True
self.version = "13"
self.finished = threading.Event()
self.force_send = False
self.public_ip_address = ""
self.public_ip_address_last_checked = 0
self.watchdog = False
self.watchdog_last_checked = 0
self.watchdog_last_sent = 0
self.ping_counter = 0
threading.Thread.start(self)
# this is a required function for all drivers, its goal is to upload some piece of data
# about your device so it can be seen on the web
def register(self):
"""Register the driver."""
# self.sendtodb("log", "BOOM! Booted.", 0)
pass
def run(self):
"""Actually run the driver."""
for i in range(0, WAIT_FOR_CONNECTION_SECONDS):
print("advvfdipp driver will start in {} seconds".format(WAIT_FOR_CONNECTION_SECONDS - i))
time.sleep(1)
log.info("BOOM! Starting advvfdipp driver...")
if PERSIST['download_pycomm']:
try:
urllib.urlretrieve('http://s3.amazonaws.com/pocloud-drivers/pycomm/clx.py', '/root/python_firmware/pycomm/ab_comm/clx.py')
urllib.urlretrieve('http://s3.amazonaws.com/pocloud-drivers/pycomm/cip_base.py', '/root/python_firmware/pycomm/cip/cip_base.py')
PERSIST['download_pycomm'] = False
persistence.store(PERSIST, "extra_data.json")
except Exception as e:
print("Could not download latest pycomm update: {}".format(e))
#self._check_watchdog()
self._check_ip_address()
self.nodes["advvfdipp_0199"] = self
send_loops = 0
convert_list = ["Device_Status_INT","sts_PID_Control","Downhole_Sensor_Status_INT","alarm_Flowmeter","alarm_IntakePressure",
"alarm_IntakeTemperature","alarm_TubingPressure","alarm_VFD","alarm_Lockout","alarm_FluidLevel","Run_Permissive_INT",
"Start_Permissive_INT","PowerFlex755.Val_LastFaultCode","sts_CurrentVFDFaultCode"]
while True:
now = time.time()
if self.force_send:
log.warning("FORCE SEND: TRUE")
for chan in CHANNELS:
try:
val = chan.read()
if "hart" in chan.mesh_name and val == None:
val = 0.0
if chan.check(val, self.force_send):
if chan.plc_tag in convert_list:
converted_value = convert_int(chan.plc_tag, val)
self.sendtodbDev(1, chan.mesh_name, converted_value, 0, 'advvfdipp')
else:
self.sendtodbDev(1, chan.mesh_name, chan.value, 0, 'advvfdipp')
#time.sleep(TAG_DATAERROR_SLEEPTIME) # sleep to allow Micro800 to handle ENET requests
except Exception as e:
log.info("Error: {}".format(e))
time.sleep(30) #sleep for 30 seconds after a full poll
# print("advvfdipp driver still alive...")
if self.force_send:
if send_loops > 2:
log.warning("Turning off force_send")
self.force_send = False
send_loops = 0
else:
send_loops += 1
if WATCHDOG_ENABLE:
if (now - self.watchdog_last_checked) > WATCHDOG_CHECK_PERIOD:
self._check_watchdog()
if (now - self.public_ip_address_last_checked) > IP_CHECK_PERIOD:
self._check_ip_address()
def _check_watchdog(self):
"""Check the watchdog and send to Meshify if changed or stale."""
test_watchdog = self.advvfdipp_watchdog()
now = time.time()
self.watchdog_last_checked = now
if test_watchdog != self.watchdog or (now - self.watchdog_last_sent) > WATCHDOG_SEND_PERIOD:
self.sendtodbDev(1, 'watchdog', test_watchdog, 0, 'advvfdipp')
self.watchdog = test_watchdog
self.watchdog_last_sent = now
def _check_ip_address(self):
"""Check the public IP address and send to Meshify if changed."""
self.public_ip_address_last_checked = time.time()
test_public_ip = get_public_ip_address()
if not test_public_ip == self.public_ip_address:
self.sendtodbDev(1, 'public_ip_address', test_public_ip, 0, 'advvfdipp')
self.public_ip_address = test_public_ip
hostname = "google.com"
response = os.system("ping -c 1 " + hostname)
#and then check the response...
if response == 0:
print hostname, 'is up!'
self.ping_counter = 0
else:
print hostname, 'is down!'
self.ping_counter += 1
if self.ping_counter >= 3:
log.info("Rebooting because no internet detected")
os.system('reboot')
def advvfdipp_watchdog(self):
"""Write a random integer to the PLC and then 1 seconds later check that it has been decremented by 1."""
randval = randint(0, 32767)
write_tag(str(PLC_IP_ADDRESS), 'watchdog_INT', randval, plc_type="CLX")
time.sleep(1)
watchdog_val = read_tag(str(PLC_IP_ADDRESS), 'watchdog_INT', plc_type="CLX")
try:
return (randval - 1) == watchdog_val[0]
except (KeyError, TypeError):
return False
def advvfdipp_sync(self, name, value):
"""Sync all data from the driver."""
self.force_send = True
# self.sendtodb("log", "synced", 0)
return True
def advvfdipp_writeplctag(self, name, value):
"""Write a value to the PLC."""
new_val = json.loads(str(value).replace("'", '"'))
tag_n = str(new_val['tag']) # "cmd_Start"
val_n = new_val['val']
write_res = write_tag(str(PLC_IP_ADDRESS), tag_n, val_n, plc_type="CLX")
print("Result of advvfdipp_writeplctag(self, {}, {}) = {}".format(name, value, write_res))
if write_res is None:
write_res = "Error writing to PLC..."
return write_res

View File

@@ -0,0 +1,14 @@
{
"files": {
"file3": "file_logger.py",
"file2": "Channel.py",
"file1": "advvfdipp.py",
"file6": "persistence.py",
"file5": "utilities.py",
"file4": "Tags.py"
},
"deviceName": "advvfdipp",
"releaseVersion": "13",
"driverFileName": "advvfdipp.py",
"driverId": "0100"
}

View File

@@ -0,0 +1,360 @@
import types
import traceback
import binascii
import threading
import time
import thread
import os
import struct
import sys
import textwrap
import Queue
import json
class deviceBase():
def __init__(self, name=None, number=None, mac=None, Q=None, mcu=None, companyId=None, offset=None, mqtt=None, Nodes=None):
self.offset = offset
self.company = companyId
self.name = name
self.number = number
self.q = Q
self.deviceName = name + '_[' + mac + ':' + number[0:2] + ':' + number[2:] + ']!'
self.chName = "M1" + '_[' + mac + ':'
self.chName2 = '_[' + mac + ':'
print 'device name is:'
print self.deviceName
mac2 = mac.replace(":", "")
self.mac = mac2.upper()
self.address = 1
self.debug = True
self.mcu = mcu
self.firstRun = True
self.mqtt = mqtt
self.nodes = Nodes
#local dictionary of derived nodes ex: localNodes[tank_0199] = self
self.localNodes = {}
os.system("chmod 777 /root/reboot")
os.system("echo nameserver 8.8.8.8 > /etc/resolv.conf")
#Queue for imcoming sets
self.loraQ = Queue.Queue()
self.knownIDs = []
thread.start_new_thread(self.getSetsThread, ())
def getSetsThread(self):
while True:
try:
item = self.loraQ.get(block=True, timeout=600)
try:
print "here is the item from the sets q"
print item
if len(item) == 2:
techname = str(json.loads(item[1])[0]['payload']['name'].split(".")[0])
channel = str(json.loads(item[1])[0]['payload']['name'].split(".")[1])
name = techname.split("_")[0]
id = techname.split("_")[1][1:-2].replace(":","").upper()
value = json.loads(item[1])[0]['payload']['value']
msgId = json.loads(item[1])[0]['msgId']
print channel, value, id, name, msgId
success = self.specificSets(channel, value, id, name)
if success == True:
print "SUCCESS ON SET"
if int(msgId) == 0:
return
lc = self.getTime()
value = str(self.mac) + " Success Setting: " + channel + " To: " + value
msg = """[ { "value":"%s", "timestamp":"%s", "msgId":"%s" } ]""" % (value, str(lc), msgId)
print value
print msg
topic = "meshify/responses/" + str(msgId)
print topic
self.q.put([topic, str(msg), 2])
else:
lc = self.getTime()
if success == False:
reason = "(Internal Gateway/Device Error)"
else:
reason = success
value = str(self.mac) + " Failed Setting: " + channel + " To: " + value + " " + reason
msg = """[ { "value":"%s", "timestamp":"%s", "msgId":"%s" } ]""" % (value, str(lc), msgId)
topic = "meshify/responses/" + msgId
self.q.put([topic, str(msg), 2])
except:
if int(msgId) == 0:
return
lc = self.getTime()
value = str(self.mac) + " Failed Setting: " + channel + " To: " + value + " (No Callback Found)"
msg = """[ { "value":"%s", "timestamp":"%s", "msgId":"%s" } ]""" % (value, str(lc), msgId)
topic = "meshify/responses/" + msgId
self.q.put([topic, str(msg), 2])
print 'no Set callback found for channel: ' + funcName
except:
print "sets queue timeout, restarting..."
def sendtodbDevLora(self, id, channel, value, timestamp, deviceName):
mac = self.mac
if deviceName == "mainMeshify":
zigmac = "_[01:00:00:00:00:" + id[0:2] + ":" + id[2:4] + ":" + id[4:6] + "]!"
else:
zigmac = "_[00:00:00:00:00:" + id[0:2] + ":" + id[2:4] + ":" + id[4:6] + "]!"
dname = deviceName + zigmac
#define dname, make id into techname and mac
if id not in self.knownIDs:
self.knownIDs.append(id)
self.mcu.xbees[dname] = self.loraQ
#meshify/db/330/C493000354FB/ilora/c493000354fb2A6E/a1-v
#[ { "value":"0.5635", "timestamp":"1486039316" } ]
if int(timestamp) == 0:
timestamp = self.getTime()
topic = 'meshify/db/%s/%s/%s/%s' % (self.company, mac, dname, channel)
print topic
msg = """[ { "value":"%s", "timestamp":"%s" } ]""" % (str(value), str(timestamp))
print msg
self.q.put([topic, msg, 0])
def sendtodbLocLora(self, id, channel, value, timestamp, deviceName):
mac = id
while len(mac) < 12:
mac = "0" + mac
if deviceName == "mainMeshify":
zigmac = "_[01:00:00:00:00:" + id[0:2] + ":" + id[2:4] + ":" + id[4:6] + "]!"
else:
zigmac = "_[00:00:00:00:00:" + id[0:2] + ":" + id[2:4] + ":" + id[4:6] + "]!"
dname = deviceName + zigmac
#define dname, make id into techname and mac
if id not in self.knownIDs:
self.knownIDs.append(id)
topic = str(("meshify/sets/" + str(self.company) + "/" + mac + "/#"))
self.mqtt.subscribe(topic, 0)
topic = str(("meshify/sets/" + "1" + "/" + mac + "/#"))
self.mqtt.subscribe(topic, 0)
self.mcu.xbees[dname] = self.loraQ
#meshify/db/330/C493000354FB/ilora/c493000354fb2A6E/a1-v
#[ { "value":"0.5635", "timestamp":"1486039316" } ]
if int(timestamp) == 0:
timestamp = self.getTime()
topic = 'meshify/db/%s/%s/%s/%s' % (self.company, mac, dname, channel)
print topic
msg = """[ { "value":"%s", "timestamp":"%s" } ]""" % (str(value), str(timestamp))
print msg
self.q.put([topic, msg, 0])
def sendtodbLocLoraCom(self, id, channel, value, timestamp, deviceName):
mac = "1" + id
while len(mac) < 12:
mac = "0" + mac
if deviceName == "mainMeshify":
zigmac = "_[01:00:00:00:00:" + id[0:2] + ":" + id[2:4] + ":" + id[4:6] + "]!"
else:
zigmac = "_[00:00:00:00:01:" + id[0:2] + ":" + id[2:4] + ":" + id[4:6] + "]!"
dname = deviceName + zigmac
#define dname, make id into techname and mac
if id not in self.knownIDs:
self.knownIDs.append(id)
topic = str(("meshify/sets/" + str(self.company) + "/" + mac + "/#"))
self.mqtt.subscribe(topic, 0)
topic = str(("meshify/sets/" + "1" + "/" + mac + "/#"))
self.mqtt.subscribe(topic, 0)
self.mcu.xbees[dname] = self.loraQ
#meshify/db/330/C493000354FB/ilora/c493000354fb2A6E/a1-v
#[ { "value":"0.5635", "timestamp":"1486039316" } ]
if int(timestamp) == 0:
timestamp = self.getTime()
topic = 'meshify/db/%s/%s/%s/%s' % (self.company, mac, dname, channel)
print topic
msg = """[ { "value":"%s", "timestamp":"%s" } ]""" % (str(value), str(timestamp))
print msg
self.q.put([topic, msg, 0])
def sendtodbLoc(self, ch, channel, value, timestamp, deviceName, mac):
#this will add your derived nodes the master nodes list, allowing them to receive sets!!
localNodesName = deviceName + "_" + str(ch) + "99"
if not self.localNodes.has_key(localNodesName):
self.localNodes[localNodesName] = True
self.nodes[localNodesName] = self
#make the techname
lst = textwrap.wrap(str(mac), width=2)
tech = ""
for i in range(len(lst)):
tech += lst[i].lower() + ":"
chName2 = '_[' + tech
if int(ch) < 10:
ch = "0" + str(int(ch))
if len(ch) > 2:
ch = ch[:-2]
dname = deviceName + chName2 + str(ch) + ":98]!"
if int(timestamp) == 0:
timestamp = self.getTime()
topic = 'meshify/db/%s/%s/%s/%s' % (self.company, mac, dname, channel)
print topic
msg = """[ { "value":"%s", "timestamp":"%s" } ]""" % (str(value), str(timestamp))
print msg
self.q.put([topic, msg, 0])
def sendtodbDevJSON(self, ch, channel, value, timestamp, deviceName):
if int(ch) < 10:
ch = "0" + str(int(ch))
dname = deviceName + self.chName2 + str(ch) + ":99]!"
if int(timestamp) == 0:
timestamp = self.getTime()
topic = 'meshify/db/%s/%s/%s/%s' % (self.company, self.mac, dname, channel)
print topic
msg = """[ { "value":%s, "timestamp":"%s" } ]""" % (str(value), str(timestamp))
print msg
self.q.put([topic, msg, 0])
def sendtodbLora(self, ch, channel, value, timestamp, deviceName):
if ":" not in ch:
ch = ch[0:2] + ":" + ch[2:4]
#this will add your derived nodes the master nodes list, allowing them to receive sets!!
localNodesName = deviceName + "_" + str(ch).replace(':', "")
if not self.localNodes.has_key(localNodesName):
self.localNodes[localNodesName] = True
self.nodes[localNodesName] = self
dname = deviceName + self.chName2 + str(ch) + "]!"
if int(timestamp) == 0:
timestamp = self.getTime()
topic = 'meshify/db/%s/%s/%s/%s' % (self.company, self.mac, dname, channel)
print topic
msg = """[ { "value":"%s", "timestamp":"%s" } ]""" % (str(value), str(timestamp))
print msg
self.q.put([topic, msg, 0])
def sendtodbDev(self, ch, channel, value, timestamp, deviceName):
#this will add your derived nodes the master nodes list, allowing them to receive sets!!
localNodesName = deviceName + "_" + str(ch) + "99"
if not self.localNodes.has_key(localNodesName):
self.localNodes[localNodesName] = True
self.nodes[localNodesName] = self
if int(ch) < 10:
ch = "0" + str(int(ch))
dname = deviceName + self.chName2 + str(ch) + ":99]!"
if int(timestamp) == 0:
timestamp = self.getTime()
topic = 'meshify/db/%s/%s/%s/%s' % (self.company, self.mac, dname, channel)
print topic
msg = """[ { "value":"%s", "timestamp":"%s" } ]""" % (str(value), str(timestamp))
print msg
self.q.put([topic, msg, 0])
def sendtodbCH(self, ch, channel, value, timestamp):
if int(ch) < 10:
ch = "0" + str(ch)
dname = self.chName + str(ch) + ":99]!"
if int(timestamp) == 0:
timestamp = self.getTime()
topic = 'meshify/db/%s/%s/%s/%s' % (self.company, self.mac, dname, channel)
print topic
msg = """[ { "value":"%s", "timestamp":"%s" } ]""" % (str(value), str(timestamp))
print msg
self.q.put([topic, msg, 0])
def sendtodb(self, channel, value, timestamp):
if int(timestamp) == 0:
timestamp = self.getTime()
if timestamp < 1400499858:
return
else:
timestamp = str(int(timestamp) + int(self.offset))
topic = 'meshify/db/%s/%s/%s/%s' % (self.company, self.mac, self.deviceName, channel)
print topic
msg = """[ { "value":"%s", "timestamp":"%s" } ]""" % (str(value), str(timestamp))
print msg
self.q.put([topic, msg, 0])
def sendtodbJSON(self, channel, value, timestamp):
if int(timestamp) == 0:
timestamp = self.getTime()
if timestamp < 1400499858:
return
else:
timestamp = str(int(timestamp) + int(self.offset))
topic = 'meshify/db/%s/%s/%s/%s' % (self.company, self.mac, self.deviceName, channel)
print topic
msg = """[ { "value":%s, "timestamp":"%s" } ]""" % (str(value), str(timestamp))
print msg
self.q.put([topic, msg, 0])
def getTime(self):
return str(int(time.time() + int(self.offset)))

View File

@@ -0,0 +1,14 @@
{
"name": "advvfdipp",
"driverFilename": "advvfdipp.py",
"driverId": "0000",
"additionalDriverFiles": [
"utilities.py",
"persistence.py",
"Channel.py",
"logger.py",
"Tags.py"
],
"version": 1,
"s3BucketName": "advvfdipp"
}

View File

@@ -0,0 +1,18 @@
"""Logging setup for advvfdipp"""
import logging
from logging.handlers import RotatingFileHandler
import sys
log_formatter = logging.Formatter('%(asctime)s %(levelname)s %(funcName)s(%(lineno)d) %(message)s')
log_file = './advvfdipp.log'
my_handler = RotatingFileHandler(log_file, mode='a', maxBytes=500*1024,
backupCount=2, encoding=None, delay=0)
my_handler.setFormatter(log_formatter)
my_handler.setLevel(logging.INFO)
filelogger = logging.getLogger('advvfdipp')
filelogger.setLevel(logging.INFO)
filelogger.addHandler(my_handler)
console_out = logging.StreamHandler(sys.stdout)
console_out.setFormatter(log_formatter)
filelogger.addHandler(console_out)

View File

@@ -0,0 +1,21 @@
"""Data persistance functions."""
# if more advanced persistence is needed, use a sqlite database
import json
def load(filename="persist.json"):
"""Load persisted settings from the specified file."""
try:
with open(filename, 'r') as persist_file:
return json.load(persist_file)
except Exception:
return False
def store(persist_obj, filename="persist.json"):
"""Store the persisting settings into the specified file."""
try:
with open(filename, 'w') as persist_file:
return json.dump(persist_obj, persist_file, indent=4)
except Exception:
return False

View File

@@ -0,0 +1,226 @@
"""Utility functions for the driver."""
import socket
import struct
from Channel import PLCChannel
def get_public_ip_address():
"""Find the public IP Address of the host device."""
sock = socket.socket(socket.AF_INET, socket.SOCK_DGRAM)
sock.connect(("8.8.8.8", 80))
ip_address = sock.getsockname()[0]
sock.close()
return ip_address
def int_to_float16(int_to_convert):
"""Convert integer into float16 representation."""
bin_rep = ('0' * 16 + '{0:b}'.format(int_to_convert))[-16:]
sign = 1.0
if int(bin_rep[0]) == 1:
sign = -1.0
exponent = float(int(bin_rep[1:6], 2))
fraction = float(int(bin_rep[6:17], 2))
if exponent == float(0b00000):
return sign * 2 ** -14 * fraction / (2.0 ** 10.0)
elif exponent == float(0b11111):
if fraction == 0:
return sign * float("inf")
return float("NaN")
frac_part = 1.0 + fraction / (2.0 ** 10.0)
return sign * (2 ** (exponent - 15)) * frac_part
def ints_to_float(int1, int2):
"""Convert 2 registers into a floating point number."""
mypack = struct.pack('>HH', int1, int2)
f_unpacked = struct.unpack('>f', mypack)
print("[{}, {}] >> {}".format(int1, int2, f_unpacked[0]))
return f_unpacked[0]
def degf_to_degc(temp_f):
"""Convert deg F to deg C."""
return (temp_f - 32.0) * (5.0/9.0)
def degc_to_degf(temp_c):
"""Convert deg C to deg F."""
return temp_c * 1.8 + 32.0
def get_additional_tags(tag_dict):
tags_array = tag_dict['additional_tags']
channel_array = []
for x in tags_array:
try:
print "Making channel {}".format(x)
channel_array.append(PLCChannel(tag_dict['ip_address'], x['mesh_name'], x['plc_tag'], x['data_type'],x['chg_threshold'],x['guarantee_sec'],plc_type='CLX'))
except Exception:
print "Nothing to write or bad key"
return channel_array
def convert_int(plc_tag, value):
well_status_codes = {
0: "Running",
1: "Pumped Off",
2: "Alarmed",
3: "Locked Out",
4: "Stopped"
}
pid_control_codes = {
0: "Flow",
1: "Fluid Level",
2: "Tubing Pressure",
3: "Manual"
}
downhole_codes = {
0: "OK",
1: "Connecting",
2: "Open Circuit",
3: "Shorted",
4: "Cannot Decode"
}
permissive_codes = {
0: "OK",
1: "Flow",
2: "Intake Pressure",
3: "Intake Temperature",
4: "Tubing Pressure",
5: "VFD",
6: "Fluid Level",
7: "Min. Downtime"
}
alarm_codes = {
0: "OK",
1: "Alarm"
}
alarm_vfd_codes = {
0: "OK",
1: "Locked Out"
}
vfd_fault_codes = {
0: "No Fault",
2: "Auxiliary Input",
3: "Power Loss",
4: "UnderVoltage",
5: "OverVoltage",
7: "Motor Overload",
8: "Heatsink OverTemp",
9: "Thermister OverTemp",
10: "Dynamic Brake OverTemp",
12: "Hardware OverCurrent",
13: "Ground Fault",
14: "Ground Warning",
15: "Load Loss",
17: "Input Phase Loss",
18: "Motor PTC Trip",
19: "Task Overrun",
20: "Torque Prove Speed Band",
21: "Output Phase Loss",
24: "Decel Inhibit",
25: "OverSpeed Limit",
26: "Brake Slipped",
27: "Torque Prove Conflict",
28: "TP Encls Confict",
29: "Analog In Loss",
33: "Auto Restarts Exhausted",
35: "IPM OverCurrent",
36: "SW OverCurrent",
38: "Phase U to Ground",
39: "Phase V to Ground",
40: "Phase W to Ground",
41: "Phase UV Short",
42: "Phase VW Short",
43: "Phase WU Short",
44: "Phase UNeg to Ground",
45: "Phase VNeg to Ground",
46: "Phase WNeg to Ground",
48: "System Defaulted",
49: "Drive Powerup",
51: "Clear Fault Queue",
55: "Control Board Overtemp",
59: "Invalid Code",
61: "Shear Pin 1",
62: "Shear Pin 2",
64: "Drive Overload",
66: "OW Torque Level",
67: "Pump Off",
71: "Port 1 Adapter",
72: "Port 2 Adapter",
73: "Port 3 Adapter",
74: "Port 4 Adapter",
75: "Port 5 Adapter",
76: "Port 6 Adapter",
77: "IR Volts Range",
78: "FluxAmps Ref Range",
79: "Excessive Load",
80: "AutoTune Aborted",
81: "Port 1 DPI Loss",
82: "Port 2 DPI Loss",
83: "Port 3 DPI Loss",
84: "Port 4 DPI Loss",
85: "Port 5 DPI Loss",
86: "Port 6 DPI Loss",
87: "IXo Voltage Range",
91: "Primary Velocity Feedback Loss",
93: "Hardware Enable Check",
94: "Alternate Velocity Feedback Loss",
95: "Auxiliary Velocity Feedback Loss",
96: "Position Feedback Loss",
97: "Auto Tach Switch",
100: "Parameter Checksum",
101: "Power Down NVS Blank",
102: "NVS Not Blank",
103: "Power Down NVS Incompatible",
104: "Power Board Checksum",
106: "Incompat MCB-PB",
107: "Replaced MCB-PB",
108: "Analog Calibration Checksum",
110: "Invalid Power Board Data",
111: "Power Board Invalid ID",
112: "Power Board App Min Version",
113: "Tracking DataError",
115: "Power Down Table Full",
116: "Power Down Entry Too Large",
117: "Power Down Data Checksum",
118: "Power Board Power Down Checksum",
124: "App ID Changed",
125: "Using Backup App",
134: "Start on Power Up",
137: "External Precharge Error",
138: "Precharge Open",
141: "Autotune Enc Angle",
142: "Autotune Speed Restricted",
143: "Autotune Current Regulator",
144: "Autotune Inertia",
145: "Autotune Travel",
13035: "Net IO Timeout",
13037: "Net IO Timeout"
}
plc_tags = {
"Device_Status_INT": well_status_codes.get(value, "Invalid Code"),
"sts_PID_Control": pid_control_codes.get(value, "Invalid Code"),
"Downhole_Sensor_Status_INT": downhole_codes.get(value, "Invalid Code"),
"alarm_Flowmeter": alarm_codes.get(value, "Invalid Code"),
"alarm_IntakePressure": alarm_codes.get(value, "Invalid Code"),
"alarm_IntakeTemperature": alarm_codes.get(value, "Invalid Code"),
"alarm_TubingPressure": alarm_codes.get(value, "Invalid Code"),
"alarm_VFD": alarm_codes.get(value, "Invalid Code"),
"alarm_Lockout": alarm_vfd_codes.get(value, "Invalid Code"),
"alarm_FluidLevel": alarm_codes.get(value, "Invalid Code"),
"Run_Permissive_INT": permissive_codes.get(value, "Invalid Code"),
"Start_Permissive_INT": permissive_codes.get(value, "Invalid Code"),
"PowerFlex755.Val_LastFaultCode": vfd_fault_codes.get(value, "Invalid Code"),
"sts_CurrentVFDFaultCode": vfd_fault_codes.get(value, "Invalid Code")
}
return plc_tags.get(plc_tag, "Invalid Tag")

12
advvfdipp/config.txt Normal file
View File

@@ -0,0 +1,12 @@
{
"files": {
"file3": "Channel.py",
"file2": "utilities.py",
"file1": "advvfdipp.py",
"file4": "modbusMap.p"
},
"deviceName": "advvfdipp",
"driverId": "0100",
"releaseVersion": "9",
"driverFileName": "advvfdipp.py"
}

4675
advvfdipp/modbusMap.p Normal file

File diff suppressed because it is too large Load Diff

79
advvfdipp/utilities.py Normal file
View File

@@ -0,0 +1,79 @@
"""Utility functions for the driver."""
import socket
import struct
import os
import json
def get_public_ip_address():
"""Find the public IP Address of the host device."""
s = socket.socket(socket.AF_INET, socket.SOCK_DGRAM)
s.connect(("8.8.8.8", 80))
ip = s.getsockname()[0]
s.close()
return ip
def int_to_float16(int_to_convert):
"""Convert integer into float16 representation."""
bin_rep = ('0' * 16 + '{0:b}'.format(int_to_convert))[-16:]
sign = 1.0
if int(bin_rep[0]) == 1:
sign = -1.0
exponent = float(int(bin_rep[1:6], 2))
if exponent == 30:
fraction = float(int("1" + bin_rep[7:17], 2))
else:
fraction = float(int(bin_rep[7:17], 2))
if exponent == float(0b00000):
return sign * 2 ** -14 * fraction / (2.0 ** 10.0)
elif exponent == float(0b11111):
if fraction == 0:
return sign * float("inf")
else:
return float("NaN")
else:
frac_part = 1.0 + fraction / (2.0 ** 10.0)
return sign * (2 ** (exponent - 15)) * frac_part
def ints_to_float(int1, int2):
"""Convert 2 registers into a floating point number."""
mypack = struct.pack('>HH', int1, int2)
f = struct.unpack('>f', mypack)
print("[{}, {}] >> {}".format(int1, int2, f[0]))
return f[0]
def degf_to_degc(temp_f):
"""Convert deg F to deg C."""
return (temp_f - 32.0) * (5.0/9.0)
def degc_to_degf(temp_c):
"""Convert deg C to deg F."""
return temp_c * 1.8 + 32.0
def get_plc_ip():
"""Get PLC IP from persistent json file"""
path = "./persistent.json"
#open the file for appending to not delete anything
#use + to create the file as needed
f = open(path, "a+")
#go to the beginning of the file
f.seek(0)
# if persistent is empty add default IP
if os.stat(path).st_size == 0:
data = {}
data["ip"] = "192.168.1.10"
json.dump(data, f)
f.close()
# load whatever is in persistent
with open(path) as json_file:
data = json.load(json_file)
plc_ip = data["ip"]
return plc_ip