updated change thresholds
This commit is contained in:
@@ -2,21 +2,21 @@ from Channel import PLCChannel, ModbusChannel
|
||||
from advvfdipp import PLC_IP_ADDRESS
|
||||
|
||||
tags = [
|
||||
PLCChannel(PLC_IP_ADDRESS, "flowrate","val_Flowmeter","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "fluidlevel","val_FluidLevel","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "intakepressure","val_IntakePressure","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "intaketemperature","val_IntakeTemperature","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "tubingpressure","val_TubingPressure","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "flowrate","val_Flowmeter","REAL", 300, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "fluidlevel","val_FluidLevel","REAL", 2, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "intakepressure","val_IntakePressure","REAL", 10, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "intaketemperature","val_IntakeTemperature","REAL", 5, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "tubingpressure","val_TubingPressure","REAL", 10, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pidcontrolmode","sts_PID_Control","BOOL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "wellstatus","Device_Status_INT","INT", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "vfdfrequency","VFD_SpeedFdbk","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "flowtotal","Flow_Total[0]","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "energytotal","Energy_Total[0]","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "vfdcurrent","VFD_OutCurrent","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "vfdfrequency","VFD_SpeedFdbk","REAL", 5, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "flowtotal","Flow_Total[0]","REAL", 100, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "energytotal","Energy_Total[0]","REAL", 10, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "vfdcurrent","VFD_OutCurrent","REAL", 5, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "downholesensorstatus","Downhole_Sensor_Status_INT","INT", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "fluidspecificgravity","cfg_FluidSpecificGravity","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "flowtotalyesterday","Flow_Total[1]","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "energytotalyesterday","Energy_Total[1]","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "flowtotalyesterday","Flow_Total[1]","REAL", 100, 86400, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "energytotalyesterday","Energy_Total[1]","REAL", 10, 86400, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "alarmflowrate","alarm_Flowmeter","BOOL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "alarmintakepressure","alarm_IntakePressure","BOOL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "alarmintaketemperature","alarm_IntakeTemperature","BOOL", 1, 3600, plc_type="CLX"),
|
||||
@@ -27,23 +27,23 @@ tags = [
|
||||
PLCChannel(PLC_IP_ADDRESS, "startpermissive","Start_Permissive_INT","INT", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "startcommand","cmd_Start","BOOL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "stopcommand","cmd_Stop","BOOL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "flowsetpoint","cfg_PID_FlowSP","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "fluidlevelsetpoint","cfg_PID_FluidLevelSP","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "manualfrequencysetpoint","cfg_PID_ManualSP","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "tubingpressuresetpoint","cfg_PID_TubingPressureSP","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "flowsetpoint","cfg_PID_FlowSP","REAL", 1, 86400, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "fluidlevelsetpoint","cfg_PID_FluidLevelSP","REAL", 1, 86400, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "manualfrequencysetpoint","cfg_PID_ManualSP","REAL", 1, 86400, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "tubingpressuresetpoint","cfg_PID_TubingPressureSP","REAL", 1, 86400, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "alarmfluidlevel","alarm_FluidLevel","BOOL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pressureshutdownlimit","AIn_IntakePressure.Val_LoLim","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pressurestartuplimit","AIn_IntakePressure.Val_HiLim","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "temperatureshutdownlimit","AIn_IntakeTemperature.Val_HiLim","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "temperaturestartuplimit","AIn_IntakeTemperature.Val_LoLim","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "sensorheight","cfg_DHSensorDistToIntake","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pressureshutdownlimit","AIn_IntakePressure.Val_LoLim","REAL", 1, 86400, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "pressurestartuplimit","AIn_IntakePressure.Val_HiLim","REAL", 1, 86400, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "temperatureshutdownlimit","AIn_IntakeTemperature.Val_HiLim","REAL", 1, 86400, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "temperaturestartuplimit","AIn_IntakeTemperature.Val_LoLim","REAL", 1, 86400, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "sensorheight","cfg_DHSensorDistToIntake","REAL", 1, 86400, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "last_vfd_fault_code","PowerFlex755.Val_LastFaultCode","INT", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "vfd_fault","sts_CurrentVFDFaultCode","INT", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "controllerfault_io","ControllerFault_IO","BOOL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "controllerfault_program","ControllerFault_Program","BOOL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "minvfdfrequency","PowerFlex755.Cfg_MinSpdRef","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "maxvfdfrequency","PowerFlex755.Cfg_MaxSpdRef","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "hartnettotal","in_HART_Flowmeter_Net","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "hartfwdtotal","in_HART_Flowmeter_Fwd","REAL", 1, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "hartrevtotal","in_HART_Flowmeter_Rev","REAL", 1, 3600, plc_type="CLX")
|
||||
PLCChannel(PLC_IP_ADDRESS, "minvfdfrequency","PowerFlex755.Cfg_MinSpdRef","REAL", 1, 86400, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "maxvfdfrequency","PowerFlex755.Cfg_MaxSpdRef","REAL", 1, 86400, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "hartnettotal","in_HART_Flowmeter_Net","REAL", 100, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "hartfwdtotal","in_HART_Flowmeter_Fwd","REAL", 100, 3600, plc_type="CLX"),
|
||||
PLCChannel(PLC_IP_ADDRESS, "hartrevtotal","in_HART_Flowmeter_Rev","REAL", 100, 3600, plc_type="CLX")
|
||||
]
|
||||
@@ -69,7 +69,7 @@ class start(threading.Thread, deviceBase):
|
||||
mqtt=mqtt, Nodes=Nodes)
|
||||
|
||||
self.daemon = True
|
||||
self.version = "14"
|
||||
self.version = "15"
|
||||
self.finished = threading.Event()
|
||||
self.force_send = False
|
||||
self.public_ip_address = ""
|
||||
|
||||
@@ -8,7 +8,7 @@
|
||||
"file4": "Tags.py"
|
||||
},
|
||||
"deviceName": "advvfdipp",
|
||||
"releaseVersion": "14",
|
||||
"releaseVersion": "15",
|
||||
"driverFileName": "advvfdipp.py",
|
||||
"driverId": "0100"
|
||||
}
|
||||
Reference in New Issue
Block a user