3.2 KiB
3.2 KiB
| 1 | MeasuringPointName | ControllerName | GroupName | UploadType | DataType | Address | Decimal | Len | ReadWrite | Unit | Description | Transform Type | MaxValue | MinValue | MaxScale | MinScale | Gain | Offset | startBit | endBit | bitMap | msecSample |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 | flowrate | advvfdipp | default | periodic | FLOAT | val_Flowmeter_BarrelsPerDay | 2 | ro | none | |||||||||||||
| 3 | fluidlevel | advvfdipp | default | periodic | FLOAT | val_FluidLevel | 2 | ro | none | |||||||||||||
| 4 | tubingpressure | advvfdipp | default | periodic | FLOAT | val_TubingPressure | 2 | ro | none | |||||||||||||
| 5 | wellstatus | advvfdipp | default | periodic | INT | Device_Status_INT | ro | none | ||||||||||||||
| 6 | vfdfrequency | advvfdipp | default | periodic | FLOAT | VFD_SpeedFdbk | 2 | ro | none | |||||||||||||
| 7 | flowtotal | advvfdipp | default | periodic | FLOAT | Flow_Total[0] | 2 | ro | none | |||||||||||||
| 8 | energytotal | advvfdipp | default | periodic | FLOAT | Energy_Total[0] | 2 | ro | none | |||||||||||||
| 9 | vfdcurrent | advvfdipp | default | periodic | FLOAT | VFD_OutCurrent | 2 | ro | none | |||||||||||||
| 10 | fluidspecificgravity | advvfdipp | default | periodic | FLOAT | cfg_FluidSpecificGravity | 2 | ro | none | |||||||||||||
| 11 | flowtotalyesterday | advvfdipp | default | periodic | FLOAT | Flow_Total[1] | 2 | ro | none | |||||||||||||
| 12 | energytotalyesterday | advvfdipp | default | periodic | FLOAT | Energy_Total[1] | 2 | ro | none | |||||||||||||
| 13 | alarmflowrate | advvfdipp | default | periodic | BIT | alarm_Flowmeter | ro | none | 0 | |||||||||||||
| 14 | alarmtubingpressure | advvfdipp | default | periodic | BIT | alarm_TubingPressure | ro | none | 0 | |||||||||||||
| 15 | alarmvfd | advvfdipp | default | periodic | BIT | alarm_VFD | ro | none | 0 | |||||||||||||
| 16 | alarmlockout | advvfdipp | default | periodic | BIT | alarm_Lockout | ro | none | 0 | |||||||||||||
| 17 | runpermissive | advvfdipp | default | periodic | INT | Run_Permissive_INT | ro | none | ||||||||||||||
| 18 | startpermissive | advvfdipp | default | periodic | INT | Start_Permissive_INT | ro | none | ||||||||||||||
| 19 | alarmfluidlevel | advvfdipp | default | periodic | BIT | alarm_FluidLevel | ro | none | 0 | |||||||||||||
| 20 | last_vfd_fault_code | advvfdipp | default | periodic | INT | PowerFlex755.Val_LastFaultCode | ro | none | ||||||||||||||
| 21 | vfd_fault | advvfdipp | default | periodic | INT | sts_CurrentVFDFaultCode | ro | none | ||||||||||||||
| 22 | controllerfault_io | advvfdipp | default | periodic | BIT | ControllerFault_IO | ro | none | 0 | |||||||||||||
| 23 | controllerfault_program | advvfdipp | default | periodic | BIT | ControllerFault_Program | ro | none | 0 | |||||||||||||
| 24 | minvfdfrequency | advvfdipp | default | periodic | FLOAT | PowerFlex755.Cfg_MinSpdRef | 2 | ro | none | |||||||||||||
| 25 | maxvfdfrequency | advvfdipp | default | periodic | FLOAT | PowerFlex755.Cfg_MaxSpdRef | 2 | ro | none | |||||||||||||
| 26 | startcommand | advvfdipp | default | periodic | BIT | cmd_Start | rw | none | 0 | |||||||||||||
| 27 | stopcommand | advvfdipp | default | periodic | BIT | cmd_Stop | rw | none | 0 | |||||||||||||
| 28 | pidcontrolmode | advvfdipp | default | periodic | DINT | sts_PID_Control | rw | none | ||||||||||||||
| 29 | flowsetpoint | advvfdipp | default | periodic | FLOAT | cfg_PID_FlowSP | 2 | rw | none | |||||||||||||
| 30 | tubingpressuresetpoint | advvfdipp | default | periodic | FLOAT | cfg_PID_TubingPressureSP | 2 | rw | none | |||||||||||||
| 31 | fluidlevelsetpoint | advvfdipp | default | periodic | FLOAT | cfg_PID_FluidLevelSP | 2 | rw | none | |||||||||||||
| 32 | manualfrequencysetpoint | advvfdipp | default | periodic | FLOAT | cfg_PID_ManualSP | 2 | rw | none | |||||||||||||
| 33 | resetalarms | advvfdipp | default | periodic | BIT | cmd_ResetAlarms | rw | none | 0 | |||||||||||||
| 34 | flowrate_gpm | advvfdipp | default | periodic | FLOAT | val_Flowmeter_BarrelsPerMinute | 2 | ro | none | |||||||||||||
| 35 | flowmeter_fault | advvfdipp | default | periodic | BIT | PROMAG_300:I1.Connection_Fault | ro | none | 0 |