@@ -281,7 +281,7 @@
{
"name": "Send Data",
"trigger": "measure_event",
"topic": "meshify/db/194/_/rigpump/",
"topic": "meshify/db/194/_/rigpump/${MAC_LOWER}",
"qos": 1,
"groups": [
"default"
@@ -318,6 +318,10 @@
{
"key": "MAC_UPPER",
"value": "00:18:05:1A:E5:37"
},
{
"key": "MAC_LOWER",
"value": "00:18:05:1a:e5:37"
}
],
"modbusSlave": {

Binary file not shown.

View File

@@ -281,13 +281,13 @@
{
"name": "Send Data",
"trigger": "measure_event",
"topic": "meshify/db/194/_/rigpump/",
"topic": "meshify/db/194/_/rigpump/${MAC_LOWER}",
"qos": 1,
"groups": [
"default"
],
"funcName": "sendData",
"script": "# Enter your python code.\nimport json\nfrom common.Logger import logger\nfrom quickfaas.remotebus import publish\nimport re, uuid\nfrom paho.mqtt import client\n\nlwtData = {\n \"init\":False,\n \"client\": client.Client(client_id=str(uuid.uuid4()), clean_session=True, userdata=None, protocol=client.MQTTv311, transport=\"tcp\")\n}\ndef lwt(mac):\n try:\n #if not lwtData[\"connected\"]:\n if not lwtData[\"init\"]:\n logger.info(\"INITIALIZING LWT CLIENT\")\n lwtData[\"client\"].username_pw_set(username=\"admin\", password=\"columbus\")\n lwtData[\"client\"].will_set(\"meshify/db/194/_/mainHP/\" + mac + \":00:00/connected\",json.dumps({\"value\":False}))\n lwtData[\"init\"] = True\n logger.info(\"Connecting to MQTT Broker for LWT purposes!!!!!!!\")\n lwtData[\"client\"].connect(\"mq194.imistaway.net\",1883, 600)\n lwtData[\"client\"].publish(\"meshify/db/194/_/mainHP/\" + mac + \":00:00/connected\", json.dumps({\"value\":True}))\n except Exception as e:\n logger.error(\"LWT DID NOT DO THE THING\")\n logger.error(e)\n\ndef sendData(message):\n #logger.debug(message)\n mac = ':'.join(re.findall('..', '%012x' % uuid.getnode()))\n lwt(mac)\n for measure in message[\"measures\"]:\n try:\n logger.debug(measure)\n if measure[\"name\"] in [\"auto_manual\", \"auto_control_mode\", \"device_status\"]:\n logger.debug(\"Converting DINT/BOOL to STRING\")\n value = convert_int(measure[\"name\"], measure[\"value\"])\n logger.debug(\"Converted {} to {}\".format(measure[\"value\"], value))\n publish(__topic__ + mac + \":01:99/\" + measure[\"name\"], json.dumps({\"value\": value}), __qos__)\n else:\n publish(__topic__ + mac + \":01:99/\" + measure[\"name\"], json.dumps({\"value\": measure[\"value\"]}), __qos__)\n except Exception as e:\n logger.error(e)\n \n #publish(__topic__, json.dumps({measure[\"name\"]: measure[\"value\"]}), __qos__)\n\ndef convert_int(plc_tag, value):\n auto_manual = {\n 0: \"Manual\",\n 1: \"Auto\"\n }\n\n auto_control_mode = {\n 0: \"Pressure\",\n 1: \"Flow\"\n }\n\n device_status = {\n 1: \"Running\",\n 64: \"Idle\",\n 128: \"Overpressure\",\n 1024: \"Faulted\"\n }\n \n plc_tags = {\n \"auto_manual\": auto_manual.get(value, \"Invalid Code\"),\n \"auto_control_mode\": auto_control_mode.get(value, \"Invalid Code\"),\n \"device_status\": device_status.get(value, \"Invalid Code\"),\n }\n\n return plc_tags.get(plc_tag, \"Invalid Tag\")\n\n ",
"script": "# Enter your python code.\nimport json\nfrom common.Logger import logger\nfrom quickfaas.remotebus import publish\nimport re, uuid\nfrom paho.mqtt import client\n\nlwtData = {\n \"init\":False,\n \"client\": client.Client(client_id=str(uuid.uuid4()), clean_session=True, userdata=None, protocol=client.MQTTv311, transport=\"tcp\")\n}\ndef lwt(mac):\n try:\n #if not lwtData[\"connected\"]:\n if not lwtData[\"init\"]:\n logger.info(\"INITIALIZING LWT CLIENT\")\n lwtData[\"client\"].username_pw_set(username=\"admin\", password=\"columbus\")\n lwtData[\"client\"].will_set(\"meshify/db/194/_/mainHP/\" + mac + \":00:00/connected\",json.dumps({\"value\":False}))\n lwtData[\"init\"] = True\n logger.info(\"Connecting to MQTT Broker for LWT purposes!!!!!!!\")\n lwtData[\"client\"].connect(\"mq194.imistaway.net\",1883, 600)\n lwtData[\"client\"].publish(\"meshify/db/194/_/mainHP/\" + mac + \":00:00/connected\", json.dumps({\"value\":True}))\n except Exception as e:\n logger.error(\"LWT DID NOT DO THE THING\")\n logger.error(e)\n\ndef sendData(message):\n #logger.debug(message)\n mac = __topic__.split(\"/\")[-1] #':'.join(re.findall('..', '%012x' % uuid.getnode()))\n lwt(mac)\n for measure in message[\"measures\"]:\n try:\n logger.debug(measure)\n if measure[\"name\"] in [\"auto_manual\", \"auto_control_mode\", \"device_status\"]:\n logger.debug(\"Converting DINT/BOOL to STRING\")\n value = convert_int(measure[\"name\"], measure[\"value\"])\n logger.debug(\"Converted {} to {}\".format(measure[\"value\"], value))\n publish(__topic__ + \":01:99/\" + measure[\"name\"], json.dumps({\"value\": value}), __qos__)\n else:\n publish(__topic__ + \":01:99/\" + measure[\"name\"], json.dumps({\"value\": measure[\"value\"]}), __qos__)\n except Exception as e:\n logger.error(e)\n \n #publish(__topic__, json.dumps({measure[\"name\"]: measure[\"value\"]}), __qos__)\n\ndef convert_int(plc_tag, value):\n auto_manual = {\n 0: \"Manual\",\n 1: \"Auto\"\n }\n\n auto_control_mode = {\n 0: \"Pressure\",\n 1: \"Flow\"\n }\n\n device_status = {\n 1: \"Running\",\n 64: \"Idle\",\n 128: \"Overpressure\",\n 1024: \"Faulted\"\n }\n \n plc_tags = {\n \"auto_manual\": auto_manual.get(value, \"Invalid Code\"),\n \"auto_control_mode\": auto_control_mode.get(value, \"Invalid Code\"),\n \"device_status\": device_status.get(value, \"Invalid Code\"),\n }\n\n return plc_tags.get(plc_tag, \"Invalid Tag\")\n\n ",
"cloudName": "default",
"msgType": 0
}
@@ -318,6 +318,10 @@
{
"key": "MAC_UPPER",
"value": "00:18:05:1A:E5:37"
},
{
"key": "MAC_LOWER",
"value": "00:18:05:1a:e5:37"
}
],
"modbusSlave": {

View File

@@ -26,7 +26,7 @@ def lwt(mac):
def sendData(message):
#logger.debug(message)
mac = ':'.join(re.findall('..', '%012x' % uuid.getnode()))
mac = __topic__.split("/")[-1] #':'.join(re.findall('..', '%012x' % uuid.getnode()))
lwt(mac)
for measure in message["measures"]:
try:
@@ -35,9 +35,9 @@ def sendData(message):
logger.debug("Converting DINT/BOOL to STRING")
value = convert_int(measure["name"], measure["value"])
logger.debug("Converted {} to {}".format(measure["value"], value))
publish(__topic__ + mac + ":01:99/" + measure["name"], json.dumps({"value": value}), __qos__)
publish(__topic__ + ":01:99/" + measure["name"], json.dumps({"value": value}), __qos__)
else:
publish(__topic__ + mac + ":01:99/" + measure["name"], json.dumps({"value": measure["value"]}), __qos__)
publish(__topic__ + ":01:99/" + measure["name"], json.dumps({"value": measure["value"]}), __qos__)
except Exception as e: