diff --git a/.DS_Store b/.DS_Store index e5a2b09..fbb6dc9 100644 Binary files a/.DS_Store and b/.DS_Store differ diff --git a/Pub_Sub/.DS_Store b/Pub_Sub/.DS_Store index 6f7593a..ed63542 100644 Binary files a/Pub_Sub/.DS_Store and b/Pub_Sub/.DS_Store differ diff --git a/Pub_Sub/ek_facility/thingsboard/ek_facility_measures.csv b/Pub_Sub/ek_facility/thingsboard/ek_facility_measures.csv index 6b3ba0a..c2689ea 100644 --- a/Pub_Sub/ek_facility/thingsboard/ek_facility_measures.csv +++ b/Pub_Sub/ek_facility/thingsboard/ek_facility_measures.csv @@ -48,11 +48,26 @@ chemical_pump_01_run_status,ek_facility,default,periodic,,BIT,,,,0,FBK_Chemical_ chemical_pump_auto,ek_facility,default,periodic,,BIT,,,,0,CMD_Chemical_Pump_Auto,,,ro,,,none,,,,,,,,,,,,,0,,1,,,,,,, compressor_ambient_temp,ek_facility,default,periodic,,FLOAT,,,,,Val_Air_Compressor_Ambient_Temp,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, compressor_controller_temp,ek_facility,default,periodic,,FLOAT,,,,,Val_Air_Compressor_Controller_Temp,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +compressor_lifetime_run_hours,ek_facility,default,periodic,,FLOAT,,,,,Val_Air_Compressor_Run_Time,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, compressor_outlet_pressure,ek_facility,default,periodic,,FLOAT,,,,,Val_Air_Compressor_Outlet_PSI,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, compressor_outlet_temp,ek_facility,default,periodic,,FLOAT,,,,,Val_Air_Compressor_Outlet_Element_Temp,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, ct_200_current,ek_facility,default,periodic,,FLOAT,,,,,CT_200.Scaled_Out,2,,ro,,M-105 Motor Amperage,none,,,,,,,,,,,,,,,1,,,,,,, dpi_108a_pressure,ek_facility,default,periodic,,FLOAT,,,,,DPI_108A,2,,ro,,Differential PSI Across Sock Filter,none,,,,,,,,,,,,,,,1,,,,,,, dpi_108b_pressure,ek_facility,default,periodic,,FLOAT,,,,,DPI_108B,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +ef_vfd_1_fault_description,ek_facility,default,periodic,,STRING,,,,,AL0_EF_VFD_1_Fault_Description,,32,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +ef_vfd_1_n2_auto,ek_facility,default,periodic,,BIT,,,,0,N2_EF_VFD_1_Auto,,,ro,,,none,,,,,,,,,,,,,0,,1,,,,,,, +ef_vfd_1_n2_auto_room_spt,ek_facility,default,periodic,,FLOAT,,,,,SPT_N2_EF_VFD_1_Auto_Room,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +ef_vfd_1_n2_faulted_alm,ek_facility,default,periodic,,BIT,,,,0,AL0_N2_EF_VFD_1_Faulted,,,ro,,,none,,,,,,,,,,,,,0,,1,,,,,,, +ef_vfd_1_n2_frequency,ek_facility,default,periodic,,DINT,,0,,,Val_N2_EF_VFD_1_Freq,,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +ef_vfd_1_n2_hand_spt,ek_facility,default,periodic,,FLOAT,,,,,SPT_N2_EF_VFD_1_Hand,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +ef_vfd_1_running,ek_facility,default,periodic,,BIT,,,,0,FBK_EF_VFD_1_Running,,,ro,,,none,,,,,,,,,,,,,0,,1,,,,,,, +ef_vfd_2_fault_description,ek_facility,default,periodic,,STRING,,,,,AL0_EF_VFD_2_Fault_Description,,32,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +ef_vfd_2_n2_auto,ek_facility,default,periodic,,BIT,,,,0,N2_EF_VFD_2_Auto,,,ro,,,none,,,,,,,,,,,,,0,,1,,,,,,, +ef_vfd_2_n2_auto_room_spt,ek_facility,default,periodic,,FLOAT,,,,,SPT_N2_EF_VFD_2_Auto_Room,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +ef_vfd_2_n2_faulted_alm,ek_facility,default,periodic,,BIT,,,,0,AL0_N2_EF_VFD_2_Faulted,,,ro,,,none,,,,,,,,,,,,,0,,1,,,,,,, +ef_vfd_2_n2_frequency,ek_facility,default,periodic,,DINT,,0,,,Val_N2_EF_VFD_2_Freq,,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +ef_vfd_2_n2_hand_spt,ek_facility,default,periodic,,FLOAT,,,,,SPT_N2_EF_VFD_2_Hand,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +ef_vfd_2_running,ek_facility,default,periodic,,BIT,,,,0,FBK_EF_VFD_2_Running,,,ro,,,none,,,,,,,,,,,,,0,,1,,,,,,, esd_exists,ek_facility,default,periodic,,BIT,,,,0,ESD_Exists,,,ro,,,none,,,,,,,,,,,,,0,,1,,,,,,, fcv_001_valve,ek_facility,default,periodic,,FLOAT,,,,,FCV_001_PRESCALE,2,,ro,,M107A Control Valve Setpoint,none,,,,,,,,,,,,,,,1,,,,,,, fcv_002_valve,ek_facility,default,periodic,,FLOAT,,,,,FCV_002_PRESCALE,2,,ro,,M107B Control Valve Setpoint,none,,,,,,,,,,,,,,,1,,,,,,, @@ -94,6 +109,8 @@ fit_111_flow_rate,ek_facility,default,periodic,,FLOAT,,,,,FIT_111.Scaled_Out,2,, fit_112a_h2o2_flow_rate,ek_facility,default,periodic,,FLOAT,,,,,FIT_112A.Scaled_Out,2,,ro,,H2O2 Flow Rate,none,,,,,,,,,,,,,,,1,,,,,,, fit_112b_nahso3_flow_rate,ek_facility,default,periodic,,FLOAT,,,,,FIT_112B.Scaled_Out,2,,ro,,NaHSO3 Flow Rate,none,,,,,,,,,,,,,,,1,,,,,,, h2o2_chemical_rate,ek_facility,default,periodic,,INT,,0,,,Chemical_Pump_1_Rate,,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +inlet_ph_temp,ek_facility,default,periodic,,FLOAT,,,,,Val_Inlet_PH_Temp,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +inlet_turbidity_temp,ek_facility,default,periodic,,FLOAT,,,,,Val_Inlet_Turbidity_Temp,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, li_103D_level_alm,ek_facility,default,periodic,,BIT,,,,0,LI_103D_FBK,,,ro,,ACW Containment Level Tripped (Red When Tripped Please),none,,,,,,,,,,,,,0,,1,,,,,,, lit_101_level,ek_facility,default,periodic,,FLOAT,,,,,LIT_101.Scaled_Out,2,,ro,,Chamber 5 Skim Level In Weir,none,,,,,,,,,,,,,,,1,,,,,,, lit_112a_h2o2_level,ek_facility,default,periodic,,FLOAT,,,,,LIT_112A.Scaled_Out,2,,ro,,H2O2 Chemical Level,none,,,,,,,,,,,,,,,1,,,,,,, @@ -121,11 +138,15 @@ m106b_vfd_faulted_alm,ek_facility,default,periodic,,BIT,,,,0,M106B_VFD:I.Faulted m106b_vfd_frequency,ek_facility,default,periodic,,INT,,0,,,M106B_VFD:I.OutputFreq,,,ro,,M-106B Current Output Frequency,none,,,,,,,,,,,,,,,1,,,,,,, m106b_vfd_start,ek_facility,default,periodic,,BIT,,,,0,M106B_VFD:O.Start,,,ro,,M-106B Start Command,none,,,,,,,,,,,,,0,,1,,,,,,, m106b_vfd_stop,ek_facility,default,periodic,,BIT,,,,0,M106B_VFD:O.Stop,,,ro,,M-106B Stop Command,none,,,,,,,,,,,,,0,,1,,,,,,, +n2_inlet_dew_point,ek_facility,default,periodic,,FLOAT,,,,,Val_N2_Inlet_Dew_Point,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, n2_inlet_pressure,ek_facility,default,periodic,,FLOAT,,,,,Val_N2_Inlet_PSI,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, n2_outlet_flow_rate,ek_facility,default,periodic,,FLOAT,,,,,Val_N2_Outlet_Flow_Rate,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, -n2_outlet_pressure,ek_facility,default,periodic,,FLOAT,,,,,Val_ N2_Outlet_ PSI,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +n2_outlet_pressure,ek_facility,default,periodic,,FLOAT,,,,,Val_N2_Outlet_PSI,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, n2_outlet_temp,ek_facility,default,periodic,,FLOAT,,,,,Val_N2_Outlet_Temp,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, n2_purity,ek_facility,default,periodic,,FLOAT,,,,,Val_N2_N2_Purity,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +n2_run_time_lifetime,ek_facility,default,periodic,,FLOAT,,,,,Val_N2_Run_Time,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +outlet_orp_temp,ek_facility,default,periodic,,FLOAT,,,,,Val_Outlet_ORP_Temp,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, +outlet_turbidity_temp,ek_facility,default,periodic,,FLOAT,,,,,Val_Outlet_Turbidity_Temp,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, p100_auto,ek_facility,default,periodic,,BIT,,,,0,P100_Auto,,,ro,,M-104 Onyx Pump HOA Auto Status,none,,,,,,,,,,,,,0,,1,,,,,,, p100_hand,ek_facility,default,periodic,,BIT,,,,0,P100_Hand,,,ro,,M-104 Onyx Pump HOA Hand Status,none,,,,,,,,,,,,,0,,1,,,,,,, p200_auto,ek_facility,default,periodic,,BIT,,,,0,P200_Auto,,,ro,,M-105 Skim Pump HOA Hand Status,none,,,,,,,,,,,,,0,,1,,,,,,, @@ -206,8 +227,4 @@ spt_chemical_manual_rate,ek_facility,default,periodic,,FLOAT,,,,,SPT_Chemical_Ma xy_100_run,ek_facility,default,periodic,,BIT,,,,0,XY_100,,,ro,,,none,,,,,,,,,,,,,0,,1,,,,,,, xy_200_run,ek_facility,default,periodic,,BIT,,,,0,XY_200,,,ro,,M-105 Run Command,none,,,,,,,,,,,,,0,,1,,,,,,, zae_111a_hihi_alm,ek_facility,default,periodic,,BIT,,,,0,ZAE_111A.AHH,,,ro,,,none,,,,,,,,,,,,,0,,1,,,,,,, -zae_111b_hihi_alm,ek_facility,default,periodic,,BIT,,,,0,ZAE_111B.AHH,,,ro,,,none,,,,,,,,,,,,,0,,1,,,,,,, -inlet_ph_temp,ek_facility,default,periodic,,FLOAT,,,,,Val_Inlet_PH_Temp,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, -inlet_turbidity_temp,ek_facility,default,periodic,,FLOAT,,,,,Val_Inlet_Turbidity_Temp,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, -outlet_orp_temp,ek_facility,default,periodic,,FLOAT,,,,,Val_Outlet_ORP_Temp,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, -outlet_turbidity_temp,ek_facility,default,periodic,,FLOAT,,,,,Val_Outlet_Turbidity_Temp,2,,ro,,,none,,,,,,,,,,,,,,,1,,,,,,, \ No newline at end of file +zae_111b_hihi_alm,ek_facility,default,periodic,,BIT,,,,0,ZAE_111B.AHH,,,ro,,,none,,,,,,,,,,,,,0,,1,,,,,,, \ No newline at end of file diff --git a/Pub_Sub/flowmeterskid/thingsboard/flowmeterskid_measures.csv b/Pub_Sub/flowmeterskid/thingsboard/flowmeterskid_measures.csv new file mode 100644 index 0000000..895040c --- /dev/null +++ b/Pub_Sub/flowmeterskid/thingsboard/flowmeterskid_measures.csv @@ -0,0 +1,16 @@ +MeasuringPointName,ControllerName,GroupName,UploadType,DeadZonePercent,DataType,ArrayIndex,EnableBit,BitIndex,reverseBit,Address,Decimal,Len,CodeType,ReadWrite,Unit,Description,Transform Type,MaxValue,MinValue,MaxScale,MinScale,Gain,Offset,startBit,endBit,Pt,Ct,Mapping_table,TransDecimal,bitMap,msecSample,storageLwTSDB,DataEndianReverse,ReadOffset,ReadLength,WriteOffset,WriteLength,DataParseMethod,BitId,pollCycle +flowrate,flowmeter,default,periodic,,FLOAT,,,,,4X3874,2,,,ro,,,none,,,,,,,,,,,,,,0,0,,,,,,,,0 +flow_unit,flowmeter,default,onChange,0,INT,,0,,,4X2103,,,,ro,,,none,,,,,,,,,,,,,,0,0,,,,,,,,0 +totalizer_1,flowmeter,default,periodic,,FLOAT,,,,,4X2610,2,,,ro,,,none,,,,,,,,,,,,,,0,0,,,,,,,,0 +totalizer_1_overflow,flowmeter,default,periodic,,FLOAT,,,,,4X2612,2,,,ro,,,none,,,,,,,,,,,,,,0,0,,,,,,,, +totalizer_1_unit,flowmeter,default,onChange,0,INT,,0,,,4X4604,,,,ro,,,none,,,,,,,,,,,,,,0,0,,,,,,,,0 +totalizer_2,flowmeter,default,periodic,,FLOAT,,,,,4X2810,2,,,ro,,,none,,,,,,,,,,,,,,0,0,,,,,,,,0 +totalizer_2_overflow,flowmeter,default,periodic,,FLOAT,,,,,4X2812,2,,,ro,,,none,,,,,,,,,,,,,,0,0,,,,,,,, +totalizer_2_unit,flowmeter,default,onChange,0,INT,,0,,,4X4605,,,,ro,,,none,,,,,,,,,,,,,,0,0,,,,,,,,0 +totalizer_3,flowmeter,default,periodic,,FLOAT,,,,,4X3010,2,,,ro,,,none,,,,,,,,,,,,,,0,0,,,,,,,,0 +totalizer_3_overflow,flowmeter,default,periodic,,FLOAT,,,,,4X3012,2,,,ro,,,none,,,,,,,,,,,,,,0,0,,,,,,,, +totalizer_3_unit,flowmeter,default,periodic,,INT,,0,,,4X4606,,,,ro,,,none,,,,,,,,,,,,,,0,0,,,,,,,,0 +reset_totalizers,flowmeter,,never,,INT,,0,,,4X2609,,,,rw,,,none,,,,,,,,,,,,,,0,,,,,,,,,0 +byte_order,flowmeter,default,onChange,0,INT,,0,,,4X4915,,,,rw,,,none,,,,,,,,,,,,,,0,0,,,,,,,,0 +device_name,flowmeter,default,onChange,,STRING,,,,,4X7238,,14,UTF-8,ro,,,none,,,,,,,,,,,,,,0,0,,,,,,,,0 +serial_number,flowmeter,default,onChange,,STRING,,,,,4X7003,,12,UTF-8,ro,,,none,,,,,,,,,,,,,,0,0,,,,,,,,0 \ No newline at end of file diff --git a/Pub_Sub/oradvvfdipp/thingsboard/advvfdipp_ma_tb.cfg b/Pub_Sub/oradvvfdipp/thingsboard/advvfdipp_ma_tb.cfg new file mode 100644 index 0000000..d002994 --- /dev/null +++ b/Pub_Sub/oradvvfdipp/thingsboard/advvfdipp_ma_tb.cfg @@ -0,0 +1,1456 @@ +{ + "controllers": [ + { + "protocol": "EtherNet/IP", + "name": "advvfdipp", + "args": { + "connectTimeOut": 2000, + "slot": 0 + }, + "samplePeriod": 10, + "expired": 10000, + "endpoint": "192.168.1.10:44818", + "desc": "", + "enable": 1, + "enableDebug": 0, + "enablepollCycle": 0, + "samplePeriod2": 60, + "_id": "000066cf56ddf209" + } + ], + "measures": [ + { + "name": "flowrate", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "val_Flowmeter", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "000066cf56dd7a55" + }, + { + "name": "fluidlevel", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "val_FluidLevel", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "000166cf56dd7ba4" + }, + { + "name": "intakepressure", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "val_IntakePressure", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "000266cf56dd8855" + }, + { + "name": "intaketemperature", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "val_IntakeTemperature", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "000366cf56dd3aa7" + }, + { + "name": "tubingpressure", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "val_TubingPressure", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "000466cf56dd5051" + }, + { + "name": "pidcontrolmode", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "BIT", + "addr": "sts_PID_Control", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "bitMap": 0, + "reverseBit": 0, + "storageLwTSDB": 0, + "_id": "000566cf56ddbe40" + }, + { + "name": "wellstatus", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "INT", + "addr": "Device_Status_INT", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "enableBit": 0, + "storageLwTSDB": 0, + "_id": "000666cf56dd93b4" + }, + { + "name": "vfdfrequency", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "VFD_SpeedFdbk", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "000766cf56ddf151" + }, + { + "name": "flowtotal", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "Flow_Total[0]", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "000866cf56dd0549" + }, + { + "name": "energytotal", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "Energy_Total[0]", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "000966cf56ddf7b3" + }, + { + "name": "vfdcurrent", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "VFD_OutCurrent", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "000a66cf56dd9247" + }, + { + "name": "downholesensorstatus", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "INT", + "addr": "Downhole_Sensor_Status_INT", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "enableBit": 0, + "storageLwTSDB": 0, + "_id": "000b66cf56dd61cd" + }, + { + "name": "fluidspecificgravity", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "cfg_FluidSpecificGravity", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "000c66cf56ddab42" + }, + { + "name": "flowtotalyesterday", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "Flow_Total[1]", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "000d66cf56dd03b1" + }, + { + "name": "energytotalyesterday", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "Energy_Total[1]", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "000e66cf56dd1454" + }, + { + "name": "alarmflowrate", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "BIT", + "addr": "alarm_Flowmeter", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "bitMap": 0, + "reverseBit": 0, + "storageLwTSDB": 0, + "_id": "000f66cf56dd57b4" + }, + { + "name": "alarmintakepressure", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "BIT", + "addr": "alarm_IntakePressure", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "bitMap": 0, + "reverseBit": 0, + "storageLwTSDB": 0, + "_id": "001066cf56ddeb53" + }, + { + "name": "alarmintaketemperature", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "BIT", + "addr": "alarm_IntakeTemperature", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "bitMap": 0, + "reverseBit": 0, + "storageLwTSDB": 0, + "_id": "001166cf56ddb5f0" + }, + { + "name": "alarmtubingpressure", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "BIT", + "addr": "alarm_TubingPressure", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "bitMap": 0, + "reverseBit": 0, + "storageLwTSDB": 0, + "_id": "001266cf56dd5e7d" + }, + { + "name": "alarmvfd", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "BIT", + "addr": "alarm_VFD", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "bitMap": 0, + "reverseBit": 0, + "storageLwTSDB": 0, + "_id": "001366cf56dd40dc" + }, + { + "name": "alarmlockout", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "BIT", + "addr": "alarm_Lockout", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "bitMap": 0, + "reverseBit": 0, + "storageLwTSDB": 0, + "_id": "001466cf56dd9f32" + }, + { + "name": "runpermissive", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "INT", + "addr": "Run_Permissive_INT", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "enableBit": 0, + "storageLwTSDB": 0, + "_id": "001566cf56dd49c5" + }, + { + "name": "startpermissive", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "INT", + "addr": "Start_Permissive_INT", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "enableBit": 0, + "storageLwTSDB": 0, + "_id": "001666cf56dd999b" + }, + { + "name": "startcommand", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "BIT", + "addr": "cmd_Start", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "bitMap": 0, + "reverseBit": 0, + "storageLwTSDB": 0, + "_id": "001766cf56dd4da2" + }, + { + "name": "stopcommand", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "BIT", + "addr": "cmd_Stop", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "bitMap": 0, + "reverseBit": 0, + "storageLwTSDB": 0, + "_id": "001866cf56dd2918" + }, + { + "name": "flowsetpoint", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "cfg_PID_FlowSP", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "001966cf56dd4e9e" + }, + { + "name": "fluidlevelsetpoint", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "cfg_PID_FluidLevelSP", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "001a66cf56dd8e26" + }, + { + "name": "manualfrequencysetpoint", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "cfg_PID_ManualSP", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "001b66cf56ddf754" + }, + { + "name": "tubingpressuresetpoint", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "cfg_PID_TubingPressureSP", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "001c66cf56dd3182" + }, + { + "name": "alarmfluidlevel", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "BIT", + "addr": "alarm_FluidLevel", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "bitMap": 0, + "reverseBit": 0, + "storageLwTSDB": 0, + "_id": "001d66cf56dd6a53" + }, + { + "name": "pressureshutdownlimit", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "AIn_IntakePressure.Val_LoLim", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "001e66cf56dd2ddc" + }, + { + "name": "pressurestartuplimit", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "AIn_IntakePressure.Val_HiLim", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "001f66cf56ddd684" + }, + { + "name": "temperatureshutdownlimit", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "AIn_IntakeTemperature.Val_HiLim", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "002066cf56dd7a34" + }, + { + "name": "temperaturestartuplimit", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "AIn_IntakeTemperature.Val_LoLim", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "002166cf56ddd839" + }, + { + "name": "sensorheight", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "cfg_DHSensorDistToIntake", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "002266cf56dd87ca" + }, + { + "name": "last_vfd_fault_code", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "INT", + "addr": "PowerFlex755.Val_LastFaultCode", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "enableBit": 0, + "storageLwTSDB": 0, + "_id": "002366cf56dd4199" + }, + { + "name": "vfd_fault", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "INT", + "addr": "sts_CurrentVFDFaultCode", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "enableBit": 0, + "storageLwTSDB": 0, + "_id": "002466cf56ddecca" + }, + { + "name": "controllerfault_io", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "BIT", + "addr": "ControllerFault_IO", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "bitMap": 0, + "reverseBit": 0, + "storageLwTSDB": 0, + "_id": "002566cf56dd19a8" + }, + { + "name": "controllerfault_program", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "BIT", + "addr": "ControllerFault_Program", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "bitMap": 0, + "reverseBit": 0, + "storageLwTSDB": 0, + "_id": "002666cf56dded30" + }, + { + "name": "minvfdfrequency", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "PowerFlex755.Cfg_MinSpdRef", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "002766cf56dd2b1d" + }, + { + "name": "maxvfdfrequency", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "PowerFlex755.Cfg_MaxSpdRef", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "002866cf56ddbadf" + }, + { + "name": "hartnettotal", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "in_HART_Flowmeter_Net", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "002966cf56ddc8e4" + }, + { + "name": "hartfwdtotal", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "in_HART_Flowmeter_Fwd", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "002a66cf56dda53a" + }, + { + "name": "hartrevtotal", + "ctrlName": "advvfdipp", + "group": "default", + "uploadType": "periodic", + "dataType": "FLOAT", + "addr": "in_HART_Flowmeter_Rev", + "decimal": 2, + "len": 1, + "readWrite": "ro", + "unit": "", + "desc": "", + "transformType": 0, + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "gain": "", + "offset": "", + "pollCycle": 0, + "storageLwTSDB": 0, + "_id": "002b66cf56dd1edd" + }, + { + "ctrlName": "advvfdipp", + "dataType": "BIT", + "addr": "cmd_Start", + "readWrite": "rw", + "uploadType": "periodic", + "group": "default", + "name": "cmd_Start", + "desc": "", + "unit": "", + "transformType": 0, + "gain": "1.0", + "offset": "0.0", + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "decimal": 2, + "pollCycle": 0, + "bitMap": 0, + "reverseBit": 0, + "storageLwTSDB": 0, + "_id": "002c66cf56dd5ba8" + }, + { + "ctrlName": "advvfdipp", + "dataType": "BIT", + "addr": "cmd_Stop", + "readWrite": "rw", + "uploadType": "periodic", + "group": "default", + "name": "cmd_Stop", + "desc": "", + "unit": "", + "transformType": 0, + "gain": "1.0", + "offset": "0.0", + "maxValue": "", + "minValue": "", + "maxScaleValue": "", + "minScaleValue": "", + "decimal": 2, + "pollCycle": 0, + "bitMap": 0, + "reverseBit": 0, + "storageLwTSDB": 0, + "_id": "002d66cf56dd924a" + } + ], + "alarmLables": [ + "default" + ], + "alarms": [], + "groups": [ + { + "name": "default", + "uploadInterval": 600, + "reference": 44, + "LwTSDBSize": 1000, + "strategy": 1, + "historyDataMode": "gateway", + "historyDataPath": "/var/user/data/dbhome/device_supervisor/LwTSDB", + "enablePerOnchange": 0, + "_id": "000066cf56dd012a" + } + ], + "misc": { + "maxAlarmRecordSz": 2000, + "logLvl": "INFO", + "coms": [ + { + "name": "rs232", + "baud": 9600, + "bits": 8, + "stopbits": 1, + "parityChk": "n" + }, + { + "name": "rs485", + "baud": 19200, + "bits": 8, + "stopbits": 1, + "parityChk": "n" + } + ], + "cacheMode": "gateway", + "cachePath": "/var/user/data/dbhome/device_supervisor/offlinedata", + "cacheSize": 10000, + "debugLogMode": "gateway", + "debugLogPath": "/var/user/data/dbhome/device_supervisor/debugLog", + "debugLogSize": 2000, + "logNum": 2, + "logSize": 1 + }, + "clouds": [ + { + "cacheSize": 10000, + "enable": 1, + "type": "Standard MQTT", + "args": { + "host": "mq194.imistaway.net", + "port": 1883, + "clientId": "wilkinson-37-ws-1-7", + "auth": 1, + "tls": 0, + "cleanSession": 1, + "mqttVersion": "v3.1.1", + "keepalive": 120, + "key": "", + "cert": "", + "rootCA": "", + "verifyServer": 0, + "verifyClient": 0, + "username": "admin", + "passwd": "columbus", + "authType": 1, + "willQos": 0, + "willRetain": 0, + "willTopic": "", + "willPayload": "", + "tlsAuth": "caSelfSigned" + }, + "name": "default", + "uploadRules": [], + "_id": "000066cf56dd4fcd" + }, + { + "_id": "0000672bd24ce59a", + "cacheSize": 10000, + "enable": 1, + "name": "ThingsBoard", + "type": "Standard MQTT", + "args": { + "host": "hp.henrypump.cloud", + "port": 1883, + "clientId": "wilkinson-37-ws-1-7", + "auth": 1, + "tls": 0, + "cleanSession": 0, + "mqttVersion": "v3.1.1", + "keepalive": 60, + "key": "", + "cert": "", + "rootCA": "", + "verifyServer": 0, + "verifyClient": 0, + "username": "REInsjHjQMhudFrLlH0B", + "passwd": "", + "willQos": 0, + "willRetain": 0, + "willTopic": "", + "willPayload": "" + }, + "uploadRules": [] + } + ], + "quickfaas": { + "genericFuncs": [], + "uploadFuncs": [ + { + "name": "Send Data", + "trigger": "measure_event", + "topic": "meshify/db/194/_/advvfdipp/${MAC_LOWER}", + "qos": 1, + "groups": [ + "default" + ], + "funcName": "sendData", + "script": "# Enter your python code.\nimport json, math, time, os\nfrom datetime import datetime as dt\nfrom common.Logger import logger\nfrom quickfaas.remotebus import publish\nfrom quickfaas.global_dict import get as get_params\nfrom quickfaas.global_dict import _set_global_args\n\nimport re, uuid\nfrom paho.mqtt import client\n\nclass RuntimeStats:\n def __init__(self):\n self.runs = {}\n self.currentRun = 0\n self.today = \"\"\n self.todayString = \"\"\n\n def manageTime(self):\n if self.todayString != dt.strftime(dt.today(), \"%Y-%m-%d\"):\n if self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"start\"] and not self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"end\"]:\n self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"end\"] = time.mktime(dt.strptime(self.todayString + \" 23:59:59\", \"%Y-%m-%d %H:%M:%S\").timetuple())\n self.addDay()\n self.today = dt.today()\n self.todayString = dt.strftime(self.today, \"%Y-%m-%d\")\n days = list(self.runs.keys())\n days.sort()\n while (dt.strptime(days[-1],\"%Y-%m-%d\") - dt.strptime(days[0], \"%Y-%m-%d\")).days > 30:\n self.removeDay(day=days[0])\n days = list(self.runs.keys())\n days.sort()\n\n def addHertzDataPoint(self, frequency):\n if frequency > 0:\n self.manageTime()\n try:\n self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"frequencies\"].append(frequency)\n except:\n self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"frequencies\"] = [frequency]\n\n def startRun(self):\n if self.checkRunning():\n self.endRun()\n self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"start\"] = time.time()\n\n def endRun(self):\n self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"end\"] = time.time()\n self.currentRun += 1\n self.runs[self.todayString][\"run_\" + str(self.currentRun)] = {\"start\":0, \"end\": 0, \"frequencies\":[]} \n\n def checkRunning(self):\n if self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"start\"] and not self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"end\"]:\n return True\n return False\n\n def addDay(self):\n self.today = dt.today()\n self.todayString = dt.strftime(self.today, \"%Y-%m-%d\")\n self.currentRun = 1\n self.runs[self.todayString] = {}\n self.runs[self.todayString][\"run_\" + str(self.currentRun)] = {\"start\":0, \"end\": 0, \"frequencies\":[]}\n\n def countRunsDay(self, day=None):\n if not day:\n day = self.todayString\n return len(self.runs[day].keys())\n\n def countRunsMultiDay(self, numDays=30):\n total_runs = 0\n for day in list(self.runs.keys()):\n total_runs += self.countRunsDay(day=day)\n return total_runs\n\n def calculateAverageHertzDay(self, day=None, returnArray=False):\n dayFrequencies = []\n if not day:\n day = self.todayString\n for run in list(self.runs[day].keys()):\n try:\n dayFrequencies += self.runs[day][run][\"frequencies\"]\n except Exception as e:\n print(\"{} missing frequency data for {}\".format(day,run))\n if returnArray:\n return dayFrequencies\n return round(math.fsum(dayFrequencies)/len(dayFrequencies),2)\n\n def calculateAverageHertzMultiDay(self, numDays=30):\n self.manageTime()\n frequencies = []\n for day in list(self.runs.keys()):\n if not day == self.todayString and (dt.strptime(self.todayString, \"%Y-%m-%d\") - dt.strptime(day, \"%Y-%m-%d\")).days <= numDays:\n try:\n frequencies += self.calculateAverageHertzDay(day=day, returnArray=True)\n except Exception as e:\n print(\"{} missing frequency data\".format(day))\n if len(frequencies):\n return round(math.fsum(frequencies)/len(frequencies), 2)\n return 0\n \n def calculateRunTimeDay(self, day=None, convertToHours=True):\n total_time = 0\n if not day:\n day = self.todayString\n for run in list(self.runs[day].keys()):\n total_time = self.runs[day][run][\"end\"] - self.runs[day][run][\"start\"] + total_time\n if convertToHours:\n return self.convertSecondstoHours(total_time)\n return total_time\n\n def calculateRunTimeMultiDay(self, numDays=30, convertToHours=True):\n total_time = 0\n for day in list(self.runs.keys()):\n if not day == self.todayString and (dt.strptime(self.todayString, \"%Y-%m-%d\") - dt.strptime(day, \"%Y-%m-%d\")).days <= numDays:\n total_time += self.calculateRunTimeDay(day=day, convertToHours=False)\n if convertToHours:\n return self.convertSecondstoHours(total_time)\n return total_time\n \n def calculateRunPercentDay(self, day=None, precise=False):\n if not day:\n day = self.todayString\n if precise:\n return (self.calculateRunTimeDay(day=day)/24) * 100\n return round((self.calculateRunTimeDay(day=day)/24) * 100, 2)\n \n\n def calculateRunPercentMultiDay(self, numDays=30, precise=False):\n self.manageTime()\n if precise:\n return (self.calculateRunTimeMultiDay()/(24*numDays)) * 100\n return round((self.calculateRunTimeMultiDay()/(24*numDays)) * 100,2)\n\n def removeDay(self, day=None):\n if not day:\n raise Exception(\"Day can not be None\")\n print(\"removing day {}\".format(day))\n del self.runs[day]\n \n def convertSecondstoHours(self, seconds):\n return round(seconds / (60*60),2)\n\n def loadDataFromFile(self, filePath=\"/var/user/files/runtimestats.json\"):\n try:\n with open(filePath, \"r\") as f:\n temp = json.load(f)\n self.runs = temp[\"data\"]\n self.currentRun = temp[\"current_run\"]\n self.today = dt.strptime(temp[\"current_day\"], \"%Y-%m-%d\")\n self.todayString = temp[\"current_day\"]\n self.manageTime()\n except:\n print(\"Could not find file at {}\".format(filePath))\n print(\"creating file\")\n self.addDay()\n try:\n with open(filePath, \"w\") as f:\n d = {\n \"current_run\": self.currentRun,\n \"current_day\": self.todayString,\n \"data\": self.runs\n }\n json.dump(d, f, indent=4)\n except Exception as e:\n print(e)\n\n def saveDataToFile(self, filePath=\"/var/user/files/runtimestats.json\"):\n try:\n print(\"Saving Runs\")\n with open(filePath, \"w\") as f:\n d = {\n \"current_run\": self.currentRun,\n \"current_day\": self.todayString,\n \"data\": self.runs\n }\n json.dump(d, f, indent=4)\n except Exception as e:\n print(e)\n\nrts = RuntimeStats()\nrts.loadDataFromFile()\nrts.saveDataToFile()\n\ndef reboot(reason=\"Rebooting for config file update\"):\n #basic = Basic()\n logger.info(\"!\" * 10 + \"REBOOTING DEVICE\" + \"!\"*10)\n logger.info(reason)\n r = os.popen(\"kill -s SIGHUP `cat /var/run/python/supervisord.pid`\").read()\n logger.info(f\"REBOOT : {r}\")\n\ndef checkFileExist(filename):\n path = \"/var/user/files\"\n if not os.path.exists(path):\n logger.info(\"no folder making files folder in var/user\")\n os.makedirs(path)\n with open(path + \"/\" + filename, \"a\") as f:\n json.dump({}, f)\n if not os.path.exists(path + \"/\" + filename):\n logger.info(\"no creds file making creds file\")\n with open(path + \"/\" + filename, \"a\") as f:\n json.dump({}, f)\n\ndef convertDStoJSON(ds):\n j = dict()\n for x in ds:\n j[x[\"key\"]] = x[\"value\"]\n return j\n\ndef convertJSONtoDS(j):\n d = []\n for key in j.keys():\n d.append({\"key\": key, \"value\": j[key]})\n return d\n\ndef checkCredentialConfig():\n logger.info(\"CHECKING CONFIG\")\n cfgpath = \"/var/user/cfg/device_supervisor/device_supervisor.cfg\"\n credspath = \"/var/user/files/creds.json\"\n cfg = dict()\n with open(cfgpath, \"r\") as f:\n cfg = json.load(f)\n clouds = cfg.get(\"clouds\")\n logger.info(clouds)\n #if not configured then try to configure from stored values\n if clouds[0][\"args\"][\"clientId\"] == \"unknown\" or clouds[0][\"args\"][\"username\"] == \"unknown\" or not clouds[0][\"args\"][\"passwd\"] or clouds[0][\"args\"][\"passwd\"] == \"unknown\":\n checkFileExist(\"creds.json\")\n with open(credspath, \"r\") as c:\n creds = json.load(c)\n if creds:\n logger.info(\"updating config with stored data\")\n clouds[0][\"args\"][\"clientId\"] = creds[\"clientId\"]\n clouds[0][\"args\"][\"username\"] = creds[\"userName\"]\n clouds[0][\"args\"][\"passwd\"] = creds[\"password\"]\n cfg[\"clouds\"] = clouds\n cfg = checkParameterConfig(cfg)\n with open(cfgpath, \"w\", encoding='utf-8') as n:\n json.dump(cfg, n, indent=1, ensure_ascii=False)\n reboot()\n else:\n #assuming clouds is filled out, if data is different then assume someone typed in something new and store it, if creds is empty fill with clouds' data\n checkFileExist(\"creds.json\")\n with open(credspath, \"r\") as c:\n logger.info(\"updating stored file with new data\")\n cfg = checkParameterConfig(cfg)\n with open(cfgpath, \"w\", encoding='utf-8') as n:\n json.dump(cfg, n, indent=1, ensure_ascii=False)\n creds = json.load(c)\n if creds:\n if creds[\"clientId\"] != clouds[0][\"args\"][\"clientId\"]:\n creds[\"clientId\"] = clouds[0][\"args\"][\"clientId\"]\n if creds[\"userName\"] != clouds[0][\"args\"][\"username\"]:\n creds[\"userName\"] = clouds[0][\"args\"][\"username\"]\n if creds[\"password\"] != clouds[0][\"args\"][\"passwd\"]:\n creds[\"password\"] = clouds[0][\"args\"][\"passwd\"]\n else:\n creds[\"clientId\"] = clouds[0][\"args\"][\"clientId\"]\n creds[\"userName\"] = clouds[0][\"args\"][\"username\"]\n creds[\"password\"] = clouds[0][\"args\"][\"passwd\"]\n with open(credspath, \"w\") as cw:\n json.dump(creds,cw)\n\ndef checkParameterConfig(cfg):\n logger.info(\"Checking Parameters!!!!\")\n paramspath = \"/var/user/files/params.json\"\n cfgparams = convertDStoJSON(cfg.get(\"labels\"))\n #check stored values \n checkFileExist(\"params.json\")\n with open(paramspath, \"r\") as f:\n logger.info(\"Opened param storage file\")\n params = json.load(f)\n if params:\n if cfgparams != params:\n #go through each param\n #if not \"unknown\" and cfg and params aren't the same take from cfg likely updated manually\n #if key in cfg but not in params copy to params\n logger.info(\"equalizing params between cfg and stored\")\n for key in cfgparams.keys():\n try:\n if cfgparams[key] != params[key] and cfgparams[key] != \"unknown\":\n params[key] = cfgparams[key]\n except:\n params[key] = cfgparams[key]\n cfg[\"labels\"] = convertJSONtoDS(params)\n _set_global_args(convertJSONtoDS(params))\n with open(paramspath, \"w\") as p:\n json.dump(params, p)\n else:\n with open(paramspath, \"w\") as p:\n logger.info(\"initializing param file with params in memory\")\n json.dump(convertDStoJSON(get_params()), p)\n cfg[\"labels\"] = get_params()\n \n return cfg\n\n\n\nlwtData = {\n \"init\":False,\n \"client\": client.Client(client_id=str(uuid.uuid4()), clean_session=True, userdata=None, protocol=client.MQTTv311, transport=\"tcp\")\n}\ndef lwt(mac):\n try:\n #if not lwtData[\"connected\"]:\n if not lwtData[\"init\"]:\n logger.info(\"INITIALIZING LWT CLIENT\")\n lwtData[\"client\"].username_pw_set(username=\"admin\", password=\"columbus\")\n lwtData[\"client\"].will_set(\"meshify/db/194/_/mainHP/\" + mac + \":00:00/connected\",json.dumps({\"value\":False}))\n lwtData[\"init\"] = True\n logger.info(\"Connecting to MQTT Broker for LWT purposes!!!!!!!\")\n lwtData[\"client\"].connect(\"mq194.imistaway.net\",1883, 600)\n lwtData[\"client\"].publish(\"meshify/db/194/_/mainHP/\" + mac + \":00:00/connected\", json.dumps({\"value\":True}))\n except Exception as e:\n logger.error(\"LWT DID NOT DO THE THING\")\n logger.error(e)\n\ndef sendData(message):\n #logger.debug(message)\n mac = __topic__.split(\"/\")[-1] #':'.join(re.findall('..', '%012x' % uuid.getnode()))\n lwt(mac)\n checkCredentialConfig()\n for measure in message[\"measures\"]:\n try:\n logger.debug(measure)\n now = (round(dt.timestamp(dt.now())/600)*600)\n if abs(now - measure[\"timestamp\"]) > 7200:\n reboot(reason=\"Poll timestamp and actual timestamp out of sync. Actual: {} Poll: {}\".format(now,measure[\"timestamp\"]))\n if measure[\"name\"] in [\"wellstatus\",\"pidcontrolmode\",\"downholesensorstatus\",\"alarmflowrate\",\"alarmintakepressure\",\"alarmintaketemperature\",\"alarmtubingpressure\",\"alarmvfd\",\"alarmlockout\",\"alarmfluidlevel\",\"runpermissive\",\"startpermissive\",\"last_vfd_fault_code\",\"vfd_fault\"]:\n logger.debug(\"Converting DINT/BOOL to STRING\")\n value = convert_int(measure[\"name\"], measure[\"value\"])\n logger.debug(\"Converted {} to {}\".format(measure[\"value\"], value))\n publish(__topic__ + \":01:99/\" + measure[\"name\"], json.dumps({\"value\": value}), __qos__)\n else:\n publish(__topic__ + \":01:99/\" + measure[\"name\"], json.dumps({\"value\": measure[\"value\"]}), __qos__)\n \n if measure[\"name\"] == \"wellstatus\":\n if measure[\"value\"] == 0 and not rts.runs[rts.todayString][\"run_\" + str(rts.currentRun)][\"start\"]:\n rts.startRun()\n rts.saveDataToFile()\n elif measure[\"value\"] > 0 and rts.runs[rts.todayString][\"run_\" + str(rts.currentRun)][\"start\"] and not rts.runs[rts.todayString][\"run_\" + str(rts.currentRun)][\"end\"]:\n rts.endRun()\n rts.saveDataToFile()\n publish(__topic__ + \":01:99/\" + \"percentRunTime30Days\", json.dumps({\"value\": rts.calculateRunPercentMultiDay()}), __qos__)\n \n if measure[\"name\"] == \"vfdfrequency\":\n if measure[\"value\"] > 0:\n rts.addHertzDataPoint(measure[\"value\"])\n rts.saveDataToFile()\n publish(__topic__ + \":01:99/\" + \"avgFrequency30Days\", json.dumps({\"value\": rts.calculateAverageHertzMultiDay()}), __qos__)\n except Exception as e:\n logger.error(e)\n \n #publish(__topic__, json.dumps({measure[\"name\"]: measure[\"value\"]}), __qos__)\n\ndef convert_int(plc_tag, value):\n well_status_codes = {\n 0: \"Running\",\n 1: \"Pumped Off\",\n 2: \"Alarmed\",\n 3: \"Locked Out\",\n 4: \"Stopped\"\n }\n\n pid_control_codes = {\n 0: \"Flow\",\n 1: \"Fluid Level\",\n 2: \"Tubing Pressure\",\n 3: \"Manual\"\n }\n\n downhole_codes = {\n 0: \"OK\",\n 1: \"Connecting\",\n 2: \"Open Circuit\",\n 3: \"Shorted\",\n 4: \"Cannot Decode\"\n }\n\n permissive_codes = {\n 0: \"OK\",\n 1: \"Flow\",\n 2: \"Intake Pressure\",\n 3: \"Intake Temperature\",\n 4: \"Tubing Pressure\",\n 5: \"VFD\",\n 6: \"Fluid Level\",\n 7: \"Min. Downtime\"\n }\n\n alarm_codes = {\n 0: \"OK\",\n 1: \"Alarm\"\n }\n\n alarm_vfd_codes = {\n 0: \"OK\",\n 1: \"Locked Out\"\n }\n\n vfd_fault_codes = {\n 0: \"No Fault\",\n 2: \"Auxiliary Input\",\n 3: \"Power Loss\",\n 4: \"UnderVoltage\",\n 5: \"OverVoltage\",\n 7: \"Motor Overload\",\n 8: \"Heatsink OverTemp\",\n 9: \"Thermister OverTemp\",\n 10: \"Dynamic Brake OverTemp\",\n 12: \"Hardware OverCurrent\",\n 13: \"Ground Fault\",\n 14: \"Ground Warning\",\n 15: \"Load Loss\",\n 17: \"Input Phase Loss\",\n 18: \"Motor PTC Trip\",\n 19: \"Task Overrun\",\n 20: \"Torque Prove Speed Band\",\n 21: \"Output Phase Loss\",\n 24: \"Decel Inhibit\",\n 25: \"OverSpeed Limit\",\n 26: \"Brake Slipped\",\n 27: \"Torque Prove Conflict\",\n 28: \"TP Encls Confict\",\n 29: \"Analog In Loss\",\n 33: \"Auto Restarts Exhausted\",\n 35: \"IPM OverCurrent\",\n 36: \"SW OverCurrent\",\n 38: \"Phase U to Ground\",\n 39: \"Phase V to Ground\",\n 40: \"Phase W to Ground\",\n 41: \"Phase UV Short\",\n 42: \"Phase VW Short\",\n 43: \"Phase WU Short\",\n 44: \"Phase UNeg to Ground\",\n 45: \"Phase VNeg to Ground\",\n 46: \"Phase WNeg to Ground\",\n 48: \"System Defaulted\",\n 49: \"Drive Powerup\",\n 51: \"Clear Fault Queue\",\n 55: \"Control Board Overtemp\",\n 59: \"Invalid Code\",\n 61: \"Shear Pin 1\",\n 62: \"Shear Pin 2\",\n 64: \"Drive Overload\",\n 66: \"OW Torque Level\",\n 67: \"Pump Off\",\n 71: \"Port 1 Adapter\",\n 72: \"Port 2 Adapter\",\n 73: \"Port 3 Adapter\",\n 74: \"Port 4 Adapter\",\n 75: \"Port 5 Adapter\",\n 76: \"Port 6 Adapter\",\n 77: \"IR Volts Range\",\n 78: \"FluxAmps Ref Range\",\n 79: \"Excessive Load\",\n 80: \"AutoTune Aborted\",\n 81: \"Port 1 DPI Loss\",\n 82: \"Port 2 DPI Loss\",\n 83: \"Port 3 DPI Loss\",\n 84: \"Port 4 DPI Loss\",\n 85: \"Port 5 DPI Loss\",\n 86: \"Port 6 DPI Loss\",\n 87: \"IXo Voltage Range\",\n 91: \"Primary Velocity Feedback Loss\",\n 93: \"Hardware Enable Check\",\n 94: \"Alternate Velocity Feedback Loss\",\n 95: \"Auxiliary Velocity Feedback Loss\",\n 96: \"Position Feedback Loss\",\n 97: \"Auto Tach Switch\",\n 100: \"Parameter Checksum\",\n 101: \"Power Down NVS Blank\",\n 102: \"NVS Not Blank\",\n 103: \"Power Down NVS Incompatible\",\n 104: \"Power Board Checksum\",\n 106: \"Incompat MCB-PB\",\n 107: \"Replaced MCB-PB\",\n 108: \"Analog Calibration Checksum\",\n 110: \"Invalid Power Board Data\",\n 111: \"Power Board Invalid ID\",\n 112: \"Power Board App Min Version\",\n 113: \"Tracking DataError\",\n 115: \"Power Down Table Full\",\n 116: \"Power Down Entry Too Large\",\n 117: \"Power Down Data Checksum\",\n 118: \"Power Board Power Down Checksum\",\n 124: \"App ID Changed\",\n 125: \"Using Backup App\",\n 134: \"Start on Power Up\",\n 137: \"External Precharge Error\",\n 138: \"Precharge Open\",\n 141: \"Autotune Enc Angle\",\n 142: \"Autotune Speed Restricted\",\n 143: \"Autotune Current Regulator\",\n 144: \"Autotune Inertia\",\n 145: \"Autotune Travel\",\n 13035: \"Net IO Timeout\",\n 13037: \"Net IO Timeout\"\n\n }\n\n plc_tags = {\n \"wellstatus\": well_status_codes.get(value, \"Invalid Code\"),\n \"pidcontrolmode\": pid_control_codes.get(value, \"Invalid Code\"),\n \"downholesensorstatus\": downhole_codes.get(value, \"Invalid Code\"),\n \"alarmflowrate\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmintakepressure\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmintaketemperature\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmtubingpressure\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmvfd\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmlockout\": alarm_vfd_codes.get(value, \"Invalid Code\"),\n \"alarmfluidlevel\": alarm_codes.get(value, \"Invalid Code\"),\n \"runpermissive\": permissive_codes.get(value, \"Invalid Code\"),\n \"startpermissive\": permissive_codes.get(value, \"Invalid Code\"),\n \"last_vfd_fault_code\": vfd_fault_codes.get(value, \"Invalid Code\"),\n \"vfd_fault\": vfd_fault_codes.get(value, \"Invalid Code\")\n }\n\n return plc_tags.get(plc_tag, \"Invalid Tag\")\n\n ", + "msgType": 0, + "cloudName": "default" + }, + { + "qos": 1, + "funcName": "sendData", + "script": "import json, os, time, math, uuid\nfrom datetime import datetime as dt\nfrom common.Logger import logger\nfrom quickfaas.remotebus import publish\nfrom quickfaas.global_dict import get as get_params\nfrom quickfaas.global_dict import _set_global_args\n\nclass RuntimeStats:\n def __init__(self):\n self.runs = {}\n self.currentRun = 0\n self.today = \"\"\n self.todayString = \"\"\n\n def manageTime(self):\n if self.todayString != dt.strftime(dt.today(), \"%Y-%m-%d\"):\n if self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"start\"] and not self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"end\"]:\n self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"end\"] = time.mktime(dt.strptime(self.todayString + \" 23:59:59\", \"%Y-%m-%d %H:%M:%S\").timetuple())\n self.addDay()\n self.today = dt.today()\n self.todayString = dt.strftime(self.today, \"%Y-%m-%d\")\n days = list(self.runs.keys())\n days.sort()\n while (dt.strptime(days[-1],\"%Y-%m-%d\") - dt.strptime(days[0], \"%Y-%m-%d\")).days > 30:\n self.removeDay(day=days[0])\n days = list(self.runs.keys())\n days.sort()\n\n def addHertzDataPoint(self, frequency):\n if frequency > 0:\n self.manageTime()\n try:\n self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"frequencies\"].append(frequency)\n except:\n self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"frequencies\"] = [frequency]\n\n def startRun(self):\n if self.checkRunning():\n self.endRun()\n self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"start\"] = time.time()\n\n def endRun(self):\n self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"end\"] = time.time()\n self.currentRun += 1\n self.runs[self.todayString][\"run_\" + str(self.currentRun)] = {\"start\":0, \"end\": 0, \"frequencies\":[]} \n\n def checkRunning(self):\n if self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"start\"] and not self.runs[self.todayString][\"run_\" + str(self.currentRun)][\"end\"]:\n return True\n return False\n\n def addDay(self):\n self.today = dt.today()\n self.todayString = dt.strftime(self.today, \"%Y-%m-%d\")\n self.currentRun = 1\n self.runs[self.todayString] = {}\n self.runs[self.todayString][\"run_\" + str(self.currentRun)] = {\"start\":0, \"end\": 0, \"frequencies\":[]}\n\n def countRunsDay(self, day=None):\n if not day:\n day = self.todayString\n return len(self.runs[day].keys())\n\n def countRunsMultiDay(self, numDays=30):\n total_runs = 0\n for day in list(self.runs.keys()):\n total_runs += self.countRunsDay(day=day)\n return total_runs\n\n def calculateAverageHertzDay(self, day=None, returnArray=False):\n dayFrequencies = []\n if not day:\n day = self.todayString\n for run in list(self.runs[day].keys()):\n try:\n dayFrequencies += self.runs[day][run][\"frequencies\"]\n except Exception as e:\n print(\"{} missing frequency data for {}\".format(day,run))\n if returnArray:\n return dayFrequencies\n return round(math.fsum(dayFrequencies)/len(dayFrequencies),2)\n\n def calculateAverageHertzMultiDay(self, numDays=30):\n self.manageTime()\n frequencies = []\n for day in list(self.runs.keys()):\n if not day == self.todayString and (dt.strptime(self.todayString, \"%Y-%m-%d\") - dt.strptime(day, \"%Y-%m-%d\")).days <= numDays:\n try:\n frequencies += self.calculateAverageHertzDay(day=day, returnArray=True)\n except Exception as e:\n print(\"{} missing frequency data\".format(day))\n if len(frequencies):\n return round(math.fsum(frequencies)/len(frequencies), 2)\n return 0\n \n def calculateRunTimeDay(self, day=None, convertToHours=True):\n total_time = 0\n if not day:\n day = self.todayString\n for run in list(self.runs[day].keys()):\n total_time = self.runs[day][run][\"end\"] - self.runs[day][run][\"start\"] + total_time\n if convertToHours:\n return self.convertSecondstoHours(total_time)\n return total_time\n\n def calculateRunTimeMultiDay(self, numDays=30, convertToHours=True):\n total_time = 0\n for day in list(self.runs.keys()):\n if not day == self.todayString and (dt.strptime(self.todayString, \"%Y-%m-%d\") - dt.strptime(day, \"%Y-%m-%d\")).days <= numDays:\n total_time += self.calculateRunTimeDay(day=day, convertToHours=False)\n if convertToHours:\n return self.convertSecondstoHours(total_time)\n return total_time\n \n def calculateRunPercentDay(self, day=None, precise=False):\n if not day:\n day = self.todayString\n if precise:\n return (self.calculateRunTimeDay(day=day)/24) * 100\n return round((self.calculateRunTimeDay(day=day)/24) * 100, 2)\n \n\n def calculateRunPercentMultiDay(self, numDays=30, precise=False):\n self.manageTime()\n if precise:\n return (self.calculateRunTimeMultiDay()/(24*numDays)) * 100\n return round((self.calculateRunTimeMultiDay()/(24*numDays)) * 100,2)\n\n def removeDay(self, day=None):\n if not day:\n raise Exception(\"Day can not be None\")\n print(\"removing day {}\".format(day))\n del self.runs[day]\n \n def convertSecondstoHours(self, seconds):\n return round(seconds / (60*60),2)\n\n def loadDataFromFile(self, filePath=\"/var/user/files/runtimestats.json\"):\n try:\n with open(filePath, \"r\") as f:\n temp = json.load(f)\n self.runs = temp[\"data\"]\n self.currentRun = temp[\"current_run\"]\n self.today = dt.strptime(temp[\"current_day\"], \"%Y-%m-%d\")\n self.todayString = temp[\"current_day\"]\n self.manageTime()\n except:\n print(\"Could not find file at {}\".format(filePath))\n print(\"creating file\")\n self.addDay()\n try:\n with open(filePath, \"w\") as f:\n d = {\n \"current_run\": self.currentRun,\n \"current_day\": self.todayString,\n \"data\": self.runs\n }\n json.dump(d, f, indent=4)\n except Exception as e:\n print(e)\n\n def saveDataToFile(self, filePath=\"/var/user/files/runtimestats.json\"):\n try:\n print(\"Saving Runs\")\n with open(filePath, \"w\") as f:\n d = {\n \"current_run\": self.currentRun,\n \"current_day\": self.todayString,\n \"data\": self.runs\n }\n json.dump(d, f, indent=4)\n except Exception as e:\n print(e)\n\ntry:\n rts_path = \"/var/user/files/runtimestats_tb.json\"\n rts = RuntimeStats()\n rts.loadDataFromFile(filePath=rts_path)\n rts.saveDataToFile(filePath=rts_path)\nexcept Exception as e:\n logger.error(f\"Error in TB start RTS: {e}\" )\n\ndef reboot(reason=\"Rebooting for config file update\"):\n #basic = Basic()\n logger.info(\"!\" * 10 + \"REBOOTING DEVICE\" + \"!\"*10)\n logger.info(reason)\n r = os.popen(\"kill -s SIGHUP `cat /var/run/python/supervisord.pid`\").read()\n logger.info(f\"REBOOT : {r}\")\n\ndef checkFileExist(filename):\n path = \"/var/user/files\"\n if not os.path.exists(path):\n logger.debug(\"no folder making files folder in var/user\")\n os.makedirs(path)\n with open(path + \"/\" + filename, \"a\") as f:\n json.dump({}, f)\n if not os.path.exists(path + \"/\" + filename):\n logger.debug(\"no creds file making creds file\")\n with open(path + \"/\" + filename, \"a\") as f:\n json.dump({}, f)\n\ndef convertDStoJSON(ds):\n j = dict()\n for x in ds:\n j[x[\"key\"]] = x[\"value\"]\n return j\n\ndef convertJSONtoDS(j):\n d = []\n for key in j.keys():\n d.append({\"key\": key, \"value\": j[key]})\n return d\n\ndef checkCredentialConfig():\n logger.debug(\"CHECKING CONFIG\")\n cfgpath = \"/var/user/cfg/device_supervisor/device_supervisor.cfg\"\n credspath = \"/var/user/files/creds.json\"\n cfg = dict()\n with open(cfgpath, \"r\") as f:\n cfg = json.load(f)\n clouds = cfg.get(\"clouds\")\n logger.debug(clouds)\n #if not configured then try to configure from stored values\n if clouds[0][\"args\"][\"clientId\"] == \"unknown\" or clouds[0][\"args\"][\"username\"] == \"unknown\" or not clouds[0][\"args\"][\"passwd\"] or clouds[0][\"args\"][\"passwd\"] == \"unknown\":\n checkFileExist(\"creds.json\")\n with open(credspath, \"r\") as c:\n creds = json.load(c)\n if creds:\n logger.debug(\"updating config with stored data\")\n clouds[0][\"args\"][\"clientId\"] = creds[\"clientId\"]\n clouds[0][\"args\"][\"username\"] = creds[\"userName\"]\n clouds[0][\"args\"][\"passwd\"] = creds[\"password\"]\n cfg[\"clouds\"] = clouds\n cfg = checkParameterConfig(cfg)\n with open(cfgpath, \"w\", encoding='utf-8') as n:\n json.dump(cfg, n, indent=1, ensure_ascii=False)\n reboot()\n else:\n #assuming clouds is filled out, if data is different then assume someone typed in something new and store it, if creds is empty fill with clouds' data\n checkFileExist(\"creds.json\")\n with open(credspath, \"r\") as c:\n logger.debug(\"updating stored file with new data\")\n cfg = checkParameterConfig(cfg)\n with open(cfgpath, \"w\", encoding='utf-8') as n:\n json.dump(cfg, n, indent=1, ensure_ascii=False)\n creds = json.load(c)\n if creds:\n if creds[\"clientId\"] != clouds[0][\"args\"][\"clientId\"]:\n creds[\"clientId\"] = clouds[0][\"args\"][\"clientId\"]\n if creds[\"userName\"] != clouds[0][\"args\"][\"username\"]:\n creds[\"userName\"] = clouds[0][\"args\"][\"username\"]\n if creds[\"password\"] != clouds[0][\"args\"][\"passwd\"]:\n creds[\"password\"] = clouds[0][\"args\"][\"passwd\"]\n else:\n creds[\"clientId\"] = clouds[0][\"args\"][\"clientId\"]\n creds[\"userName\"] = clouds[0][\"args\"][\"username\"]\n creds[\"password\"] = clouds[0][\"args\"][\"passwd\"]\n with open(credspath, \"w\") as cw:\n json.dump(creds,cw)\n\ndef checkParameterConfig(cfg):\n logger.debug(\"Checking Parameters!!!!\")\n paramspath = \"/var/user/files/params.json\"\n cfgparams = convertDStoJSON(cfg.get(\"labels\"))\n #check stored values \n checkFileExist(\"params.json\")\n with open(paramspath, \"r\") as f:\n logger.debug(\"Opened param storage file\")\n params = json.load(f)\n if params:\n if cfgparams != params:\n #go through each param\n #if not \"unknown\" and cfg and params aren't the same take from cfg likely updated manually\n #if key in cfg but not in params copy to params\n logger.debug(\"equalizing params between cfg and stored\")\n for key in cfgparams.keys():\n try:\n if cfgparams[key] != params[key] and cfgparams[key] != \"unknown\":\n params[key] = cfgparams[key]\n except:\n params[key] = cfgparams[key]\n cfg[\"labels\"] = convertJSONtoDS(params)\n _set_global_args(convertJSONtoDS(params))\n with open(paramspath, \"w\") as p:\n json.dump(params, p)\n else:\n with open(paramspath, \"w\") as p:\n logger.debug(\"initializing param file with params in memory\")\n json.dump(convertDStoJSON(get_params()), p)\n cfg[\"labels\"] = get_params()\n \n return cfg\n\n# Helper function to split the payload into chunks\ndef chunk_payload(payload, chunk_size=20):\n chunked_values = list(payload[\"values\"].items())\n for i in range(0, len(chunked_values), chunk_size):\n yield {\n \"ts\": payload[\"ts\"],\n \"values\": dict(chunked_values[i:i+chunk_size])\n }\n\ndef sendData(message):\n #logger.debug(message)\n try:\n checkCredentialConfig()\n except Exception as e:\n logger.error(e)\n payload = {\"ts\": (round(dt.timestamp(dt.now())/600)*600)*1000, \"values\": {}}\n for measure in message[\"measures\"]:\n try:\n logger.debug(measure)\n if abs(payload[\"ts\"]/1000 - measure[\"timestamp\"]) > 3600:\n reboot(reason=\"Poll timestamp and actual timestamp out of sync. Actual: {} Poll: {}\".format(payload[\"ts\"]/1000,measure[\"timestamp\"]))\n if measure[\"name\"] in [\"wellstatus\",\"pidcontrolmode\",\"downholesensorstatus\",\"alarmflowrate\",\"alarmintakepressure\",\"alarmintaketemperature\",\"alarmtubingpressure\",\"alarmvfd\",\"alarmlockout\",\"alarmfluidlevel\",\"runpermissive\",\"startpermissive\",\"last_vfd_fault_code\",\"vfd_fault\", \"flowmeter_fault\"]:\n logger.debug(\"Converting DINT/BOOL to STRING\")\n value = convert_int(measure[\"name\"], measure[\"value\"])\n logger.debug(\"Converted {} to {}\".format(measure[\"value\"], value))\n payload[\"values\"][measure[\"name\"]] = value\n payload[\"values\"][measure[\"name\"] + \"_int\"] = measure[\"value\"]\n else:\n payload[\"values\"][measure[\"name\"]] = measure[\"value\"]\n if measure[\"name\"] == \"wellstatus\":\n if measure[\"value\"] == 0 and not rts.runs[rts.todayString][\"run_\" + str(rts.currentRun)][\"start\"]:\n rts.startRun()\n rts.saveDataToFile(filePath=rts_path)\n elif measure[\"value\"] > 0 and rts.runs[rts.todayString][\"run_\" + str(rts.currentRun)][\"start\"] and not rts.runs[rts.todayString][\"run_\" + str(rts.currentRun)][\"end\"]:\n rts.endRun()\n rts.saveDataToFile(filePath=rts_path)\n logger.info(f\"Adding {rts.calculateRunPercentMultiDay()} to payload as percentRunTime30Days\")\n payload[\"values\"][\"percentRunTime30Days\"] = rts.calculateRunPercentMultiDay()\n \n \n if measure[\"name\"] == \"vfdfrequency\":\n if measure[\"value\"] > 0:\n rts.addHertzDataPoint(measure[\"value\"])\n rts.saveDataToFile(filePath=rts_path)\n logger.info(f\"Adding {rts.calculateAverageHertzMultiDay()} to payload as avgFrequency30Days\")\n payload[\"values\"][\"avgFrequency30Days\"] = rts.calculateAverageHertzMultiDay()\n \n except Exception as e:\n logger.error(e)\n \n for chunk in chunk_payload(payload=payload):\n publish(__topic__, json.dumps(chunk), __qos__, cloud_name=\"ThingsBoard\")\n time.sleep(2)\n publish(\"v1/devices/me/attributes\", json.dumps({\"latestReportTime\": (round(dt.timestamp(dt.now())/600)*600)*1000}), __qos__, cloud_name=\"ThingsBoard\")\n\ndef convert_int(plc_tag, value):\n well_status_codes = {\n 0: \"Running\",\n 1: \"Pumped Off\",\n 2: \"Alarmed\",\n 3: \"Locked Out\",\n 4: \"Stopped\"\n }\n\n pid_control_codes = {\n 0: \"Flow\",\n 1: \"Fluid Level\",\n 2: \"Tubing Pressure\",\n 3: \"Manual\"\n }\n\n downhole_codes = {\n 0: \"OK\",\n 1: \"Connecting\",\n 2: \"Open Circuit\",\n 3: \"Shorted\",\n 4: \"Cannot Decode\"\n }\n\n permissive_codes = {\n 0: \"OK\",\n 1: \"Flow\",\n 2: \"Intake Pressure\",\n 3: \"Intake Temperature\",\n 4: \"Tubing Pressure\",\n 5: \"VFD\",\n 6: \"Fluid Level\",\n 7: \"Min. Downtime\"\n }\n\n alarm_codes = {\n 0: \"OK\",\n 1: \"Alarm\"\n }\n\n alarm_vfd_codes = {\n 0: \"OK\",\n 1: \"Locked Out\"\n }\n\n vfd_fault_codes = {\n 0: \"No Fault\",\n 2: \"Auxiliary Input\",\n 3: \"Power Loss\",\n 4: \"UnderVoltage\",\n 5: \"OverVoltage\",\n 7: \"Motor Overload\",\n 8: \"Heatsink OverTemp\",\n 9: \"Thermister OverTemp\",\n 10: \"Dynamic Brake OverTemp\",\n 12: \"Hardware OverCurrent\",\n 13: \"Ground Fault\",\n 14: \"Ground Warning\",\n 15: \"Load Loss\",\n 17: \"Input Phase Loss\",\n 18: \"Motor PTC Trip\",\n 19: \"Task Overrun\",\n 20: \"Torque Prove Speed Band\",\n 21: \"Output Phase Loss\",\n 24: \"Decel Inhibit\",\n 25: \"OverSpeed Limit\",\n 26: \"Brake Slipped\",\n 27: \"Torque Prove Conflict\",\n 28: \"TP Encls Confict\",\n 29: \"Analog In Loss\",\n 33: \"Auto Restarts Exhausted\",\n 35: \"IPM OverCurrent\",\n 36: \"SW OverCurrent\",\n 38: \"Phase U to Ground\",\n 39: \"Phase V to Ground\",\n 40: \"Phase W to Ground\",\n 41: \"Phase UV Short\",\n 42: \"Phase VW Short\",\n 43: \"Phase WU Short\",\n 44: \"Phase UNeg to Ground\",\n 45: \"Phase VNeg to Ground\",\n 46: \"Phase WNeg to Ground\",\n 48: \"System Defaulted\",\n 49: \"Drive Powerup\",\n 51: \"Clear Fault Queue\",\n 55: \"Control Board Overtemp\",\n 59: \"Invalid Code\",\n 61: \"Shear Pin 1\",\n 62: \"Shear Pin 2\",\n 64: \"Drive Overload\",\n 66: \"OW Torque Level\",\n 67: \"Pump Off\",\n 71: \"Port 1 Adapter\",\n 72: \"Port 2 Adapter\",\n 73: \"Port 3 Adapter\",\n 74: \"Port 4 Adapter\",\n 75: \"Port 5 Adapter\",\n 76: \"Port 6 Adapter\",\n 77: \"IR Volts Range\",\n 78: \"FluxAmps Ref Range\",\n 79: \"Excessive Load\",\n 80: \"AutoTune Aborted\",\n 81: \"Port 1 DPI Loss\",\n 82: \"Port 2 DPI Loss\",\n 83: \"Port 3 DPI Loss\",\n 84: \"Port 4 DPI Loss\",\n 85: \"Port 5 DPI Loss\",\n 86: \"Port 6 DPI Loss\",\n 87: \"IXo Voltage Range\",\n 91: \"Primary Velocity Feedback Loss\",\n 93: \"Hardware Enable Check\",\n 94: \"Alternate Velocity Feedback Loss\",\n 95: \"Auxiliary Velocity Feedback Loss\",\n 96: \"Position Feedback Loss\",\n 97: \"Auto Tach Switch\",\n 100: \"Parameter Checksum\",\n 101: \"Power Down NVS Blank\",\n 102: \"NVS Not Blank\",\n 103: \"Power Down NVS Incompatible\",\n 104: \"Power Board Checksum\",\n 106: \"Incompat MCB-PB\",\n 107: \"Replaced MCB-PB\",\n 108: \"Analog Calibration Checksum\",\n 110: \"Invalid Power Board Data\",\n 111: \"Power Board Invalid ID\",\n 112: \"Power Board App Min Version\",\n 113: \"Tracking DataError\",\n 115: \"Power Down Table Full\",\n 116: \"Power Down Entry Too Large\",\n 117: \"Power Down Data Checksum\",\n 118: \"Power Board Power Down Checksum\",\n 124: \"App ID Changed\",\n 125: \"Using Backup App\",\n 134: \"Start on Power Up\",\n 137: \"External Precharge Error\",\n 138: \"Precharge Open\",\n 141: \"Autotune Enc Angle\",\n 142: \"Autotune Speed Restricted\",\n 143: \"Autotune Current Regulator\",\n 144: \"Autotune Inertia\",\n 145: \"Autotune Travel\",\n 13035: \"Net IO Timeout\",\n 13037: \"Net IO Timeout\"\n\n }\n\n plc_tags = {\n \"wellstatus\": well_status_codes.get(value, \"Invalid Code\"),\n \"pidcontrolmode\": pid_control_codes.get(value, \"Invalid Code\"),\n \"downholesensorstatus\": downhole_codes.get(value, \"Invalid Code\"),\n \"alarmflowrate\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmintakepressure\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmintaketemperature\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmtubingpressure\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmvfd\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmlockout\": alarm_vfd_codes.get(value, \"Invalid Code\"),\n \"alarmfluidlevel\": alarm_codes.get(value, \"Invalid Code\"),\n \"runpermissive\": permissive_codes.get(value, \"Invalid Code\"),\n \"startpermissive\": permissive_codes.get(value, \"Invalid Code\"),\n \"last_vfd_fault_code\": vfd_fault_codes.get(value, \"Invalid Code\"),\n \"vfd_fault\": vfd_fault_codes.get(value, \"Invalid Code\"),\n \"flowmeter_fault\": alarm_codes.get(value, \"Invalid Code\")\n }\n\n return plc_tags.get(plc_tag, \"Invalid Tag\")\n\n ", + "name": "sendData", + "trigger": "measure_event", + "topic": "v1/devices/me/telemetry", + "msgType": 0, + "cloudName": "ThingsBoard", + "groups": [ + "default" + ] + } + ], + "downloadFuncs": [ + { + "name": "Commands", + "topic": "meshify/sets/194/${MAC_UPPER}:01:99", + "qos": 1, + "funcName": "receiveCommand", + "payload_type": "Plaintext", + "script": "# Enter your python code.\nimport json\nfrom quickfaas.measure import recall\nfrom common.Logger import logger\n\ndef sync(mac,value, wizard_api):\n #get new values and send\n try:\n data = recall()#json.loads(recall().decode(\"utf-8\"))\n except Exception as e:\n logger.error(e)\n logger.info(data)\n for controller in data:\n for measure in controller[\"measures\"]:\n #publish measure\n topic = \"meshify/db/194/_/advvfdipp/\" + mac + \"/\" + measure[\"name\"]\n if measure[\"name\"] in [\"wellstatus\",\"pidcontrolmode\",\"downholesensorstatus\",\"alarmflowrate\",\"alarmintakepressure\",\"alarmintaketemperature\",\"alarmtubingpressure\",\"alarmvfd\",\"alarmlockout\",\"alarmfluidlevel\",\"runpermissive\",\"startpermissive\",\"last_vfd_fault_code\",\"vfd_fault\"]:\n payload = [{\"value\": convert_int(measure[\"name\"], measure[\"value\"])}]\n else:\n payload = [{\"value\": measure[\"value\"]}]\n logger.debug(\"Sending on topic: {}\".format(topic))\n logger.debug(\"Sending value: {}\".format(payload))\n wizard_api.mqtt_publish(topic, json.dumps(payload))\ndef writeplctag(mac, value, wizard_api):\n try:\n value = json.loads(value.replace(\"'\",'\"'))\n logger.debug(value)\n message = {\"advvfdipp\":{value[\"tag\"]: value[\"val\"]}}\n wizard_api.write_plc_values(message)\n except Exception as e:\n logger.debug(e)\n \ndef receiveCommand(topic, payload, wizard_api):\n logger.debug(topic)\n logger.debug(json.loads(payload))\n p = json.loads(payload)[0]\n command = p[\"payload\"][\"name\"].split(\".\")[1]\n commands = {\n \"sync\": sync,\n \"writeplctag\": writeplctag,\n }\n commands[command](p[\"mac\"].lower(),p[\"payload\"][\"value\"], wizard_api)\n #logger.debug(command)\n ack(p[\"msgId\"], p[\"mac\"], command, p[\"payload\"][\"name\"].split(\".\")[1], p[\"payload\"][\"value\"], wizard_api)\n\ndef ack(msgid, mac, name, command, value, wizard_api):\n #logger.debug(mac)\n macsquish = \"\".join(mac.split(\":\")[:-2])\n maclower = \":\".join(mac.split(\":\")[:-2])\n maclower = maclower.lower()\n #logger.debug(msgid)\n #logger.debug(mac)\n #logger.debug(name)\n #logger.debug(value)\n wizard_api.mqtt_publish(\"meshify/responses/\" + str(msgid), json.dumps([{\"value\": \"{} Success Setting: {} To: {}\".format(macsquish,name, value), \"msgid\": str(msgid)}]))\n wizard_api.mqtt_publish(\"meshify/db/194/_/mainMeshify/\" + maclower + \":00:00/commands\", json.dumps([{\"value\": {\"status\": \"success\", \"value\": str(value), \"channel\": command}, \"msgid\": str(msgid)}]))\n\ndef convert_int(plc_tag, value):\n well_status_codes = {\n 0: \"Running\",\n 1: \"Pumped Off\",\n 2: \"Alarmed\",\n 3: \"Locked Out\",\n 4: \"Stopped\"\n }\n\n pid_control_codes = {\n 0: \"Flow\",\n 1: \"Fluid Level\",\n 2: \"Tubing Pressure\",\n 3: \"Manual\"\n }\n\n downhole_codes = {\n 0: \"OK\",\n 1: \"Connecting\",\n 2: \"Open Circuit\",\n 3: \"Shorted\",\n 4: \"Cannot Decode\"\n }\n\n permissive_codes = {\n 0: \"OK\",\n 1: \"Flow\",\n 2: \"Intake Pressure\",\n 3: \"Intake Temperature\",\n 4: \"Tubing Pressure\",\n 5: \"VFD\",\n 6: \"Fluid Level\",\n 7: \"Min. Downtime\"\n }\n\n alarm_codes = {\n 0: \"OK\",\n 1: \"Alarm\"\n }\n\n alarm_vfd_codes = {\n 0: \"OK\",\n 1: \"Locked Out\"\n }\n\n vfd_fault_codes = {\n 0: \"No Fault\",\n 2: \"Auxiliary Input\",\n 3: \"Power Loss\",\n 4: \"UnderVoltage\",\n 5: \"OverVoltage\",\n 7: \"Motor Overload\",\n 8: \"Heatsink OverTemp\",\n 9: \"Thermister OverTemp\",\n 10: \"Dynamic Brake OverTemp\",\n 12: \"Hardware OverCurrent\",\n 13: \"Ground Fault\",\n 14: \"Ground Warning\",\n 15: \"Load Loss\",\n 17: \"Input Phase Loss\",\n 18: \"Motor PTC Trip\",\n 19: \"Task Overrun\",\n 20: \"Torque Prove Speed Band\",\n 21: \"Output Phase Loss\",\n 24: \"Decel Inhibit\",\n 25: \"OverSpeed Limit\",\n 26: \"Brake Slipped\",\n 27: \"Torque Prove Conflict\",\n 28: \"TP Encls Confict\",\n 29: \"Analog In Loss\",\n 33: \"Auto Restarts Exhausted\",\n 35: \"IPM OverCurrent\",\n 36: \"SW OverCurrent\",\n 38: \"Phase U to Ground\",\n 39: \"Phase V to Ground\",\n 40: \"Phase W to Ground\",\n 41: \"Phase UV Short\",\n 42: \"Phase VW Short\",\n 43: \"Phase WU Short\",\n 44: \"Phase UNeg to Ground\",\n 45: \"Phase VNeg to Ground\",\n 46: \"Phase WNeg to Ground\",\n 48: \"System Defaulted\",\n 49: \"Drive Powerup\",\n 51: \"Clear Fault Queue\",\n 55: \"Control Board Overtemp\",\n 59: \"Invalid Code\",\n 61: \"Shear Pin 1\",\n 62: \"Shear Pin 2\",\n 64: \"Drive Overload\",\n 66: \"OW Torque Level\",\n 67: \"Pump Off\",\n 71: \"Port 1 Adapter\",\n 72: \"Port 2 Adapter\",\n 73: \"Port 3 Adapter\",\n 74: \"Port 4 Adapter\",\n 75: \"Port 5 Adapter\",\n 76: \"Port 6 Adapter\",\n 77: \"IR Volts Range\",\n 78: \"FluxAmps Ref Range\",\n 79: \"Excessive Load\",\n 80: \"AutoTune Aborted\",\n 81: \"Port 1 DPI Loss\",\n 82: \"Port 2 DPI Loss\",\n 83: \"Port 3 DPI Loss\",\n 84: \"Port 4 DPI Loss\",\n 85: \"Port 5 DPI Loss\",\n 86: \"Port 6 DPI Loss\",\n 87: \"IXo Voltage Range\",\n 91: \"Primary Velocity Feedback Loss\",\n 93: \"Hardware Enable Check\",\n 94: \"Alternate Velocity Feedback Loss\",\n 95: \"Auxiliary Velocity Feedback Loss\",\n 96: \"Position Feedback Loss\",\n 97: \"Auto Tach Switch\",\n 100: \"Parameter Checksum\",\n 101: \"Power Down NVS Blank\",\n 102: \"NVS Not Blank\",\n 103: \"Power Down NVS Incompatible\",\n 104: \"Power Board Checksum\",\n 106: \"Incompat MCB-PB\",\n 107: \"Replaced MCB-PB\",\n 108: \"Analog Calibration Checksum\",\n 110: \"Invalid Power Board Data\",\n 111: \"Power Board Invalid ID\",\n 112: \"Power Board App Min Version\",\n 113: \"Tracking DataError\",\n 115: \"Power Down Table Full\",\n 116: \"Power Down Entry Too Large\",\n 117: \"Power Down Data Checksum\",\n 118: \"Power Board Power Down Checksum\",\n 124: \"App ID Changed\",\n 125: \"Using Backup App\",\n 134: \"Start on Power Up\",\n 137: \"External Precharge Error\",\n 138: \"Precharge Open\",\n 141: \"Autotune Enc Angle\",\n 142: \"Autotune Speed Restricted\",\n 143: \"Autotune Current Regulator\",\n 144: \"Autotune Inertia\",\n 145: \"Autotune Travel\",\n 13035: \"Net IO Timeout\",\n 13037: \"Net IO Timeout\"\n\n }\n\n plc_tags = {\n \"wellstatus\": well_status_codes.get(value, \"Invalid Code\"),\n \"pidcontrolmode\": pid_control_codes.get(value, \"Invalid Code\"),\n \"downholesensorstatus\": downhole_codes.get(value, \"Invalid Code\"),\n \"alarmflowrate\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmintakepressure\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmintaketemperature\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmtubingpressure\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmvfd\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmlockout\": alarm_vfd_codes.get(value, \"Invalid Code\"),\n \"alarmfluidlevel\": alarm_codes.get(value, \"Invalid Code\"),\n \"runpermissive\": permissive_codes.get(value, \"Invalid Code\"),\n \"startpermissive\": permissive_codes.get(value, \"Invalid Code\"),\n \"last_vfd_fault_code\": vfd_fault_codes.get(value, \"Invalid Code\"),\n \"vfd_fault\": vfd_fault_codes.get(value, \"Invalid Code\")\n }\n\n return plc_tags.get(plc_tag, \"Invalid Tag\")\n", + "msgType": 0, + "trigger": "command_event", + "cloudName": "default" + }, + { + "name": "receiveCommand", + "topic": "v1/devices/me/rpc/request/+", + "qos": 1, + "funcName": "receiveCommand", + "payload_type": "Plaintext", + "script": "import json, time\nfrom datetime import datetime as dt\nfrom quickfaas.measure import recall, write\nfrom quickfaas.remotebus import publish\nfrom common.Logger import logger\n\n# Helper function to split the payload into chunks\ndef chunk_payload(payload, chunk_size=20):\n chunked_values = list(payload[\"values\"].items())\n for i in range(0, len(chunked_values), chunk_size):\n yield {\n \"ts\": payload[\"ts\"],\n \"values\": dict(chunked_values[i:i+chunk_size])\n }\n\ndef sync():\n #get new values and send\n payload = {\"ts\": round(dt.timestamp(dt.now()))*1000, \"values\": {}}\n topic = \"v1/devices/me/telemetry\"\n try:\n data = recall()#json.loads(recall().decode(\"utf-8\"))\n except Exception as e:\n logger.error(e)\n logger.debug(data)\n for controller in data:\n for measure in controller[\"measures\"]:\n #publish measure\n if measure[\"name\"] in [\"wellstatus\",\"pidcontrolmode\",\"downholesensorstatus\",\"alarmflowrate\",\"alarmintakepressure\",\"alarmintaketemperature\",\"alarmtubingpressure\",\"alarmvfd\",\"alarmlockout\",\"alarmfluidlevel\",\"runpermissive\",\"startpermissive\",\"last_vfd_fault_code\",\"vfd_fault\", \"flowmeter_fault\"]:\n payload[\"values\"][measure[\"name\"]] = convert_int(measure[\"name\"], measure[\"value\"])\n payload[\"values\"][measure[\"name\"]+ \"_int\"] = measure[\"value\"]\n else:\n payload[\"values\"][measure[\"name\"]] = measure[\"value\"]\n logger.debug(\"Sending on topic: {}\".format(topic))\n logger.debug(\"Sending value: {}\".format(payload))\n for chunk in chunk_payload(payload=payload):\n publish(topic, json.dumps(chunk), 1, cloud_name=\"ThingsBoard\")\n time.sleep(2)\ndef writeplctag(value):\n #value in the form {\"measurement\": , \"value\": }\n try:\n #value = json.loads(value.replace(\"'\",'\"'))\n logger.debug(value)\n #payload format: [{\"name\": \"advvfdipp\", \"measures\": [{\"name\": \"manualfrequencysetpoint\", \"value\": 49}]}]\n message = [{\"name\": \"advvfdipp\", \"measures\":[{\"name\":value[\"measurement\"], \"value\": value[\"value\"]}]}]\n resp = write(message) \n logger.debug(\"RETURN FROM WRITE: {}\".format(resp))\n return True\n except Exception as e:\n logger.debug(e)\n return False\n \ndef receiveCommand(topic, payload):\n try:\n logger.debug(topic)\n logger.debug(json.loads(payload))\n p = json.loads(payload)\n command = p[\"method\"]\n commands = {\n \"sync\": sync,\n \"writeplctag\": writeplctag,\n } \n if command == \"setPLCTag\":\n try:\n result = commands[\"writeplctag\"](p[\"params\"])\n logger.debug(result)\n except Exception as e:\n logger.error(e)\n elif command == \"changeSetpoint\":\n try:\n logger.debug(\"attempting controlpoint write\")\n params_type = {\"measurement\": \"pidcontrolmode\", \"value\": p[\"params\"][\"setpointType\"]}\n if params_type[\"value\"]:\n commands[\"writeplctag\"](params_type)\n time.sleep(2)\n except Exception as e:\n logger.error(\"DID NOT WRITE CONTROL MODE\")\n logger.error(e)\n try:\n logger.debug(\"attempting setpoint write\")\n modes = {0: \"flowsetpoint\", 1: \"fluidlevelsetpoint\", 2: \"tubingpressuresetpoint\", 3: \"manualfrequencysetpoint\"}\n params_value = {\"value\": p[\"params\"][\"setpointValue\"]}\n if params_value[\"value\"]:\n params_value[\"measurement\"] = modes[getMode()]\n result = commands[\"writeplctag\"](params_value)\n logger.debug(result)\n except Exception as e:\n logger.error(\"DID NOT WRITE SETPOINT\")\n logger.error(e)\n #logger.debug(command)\n ack(topic.split(\"/\")[-1])\n time.sleep(5)\n sync()\n except Exception as e:\n logger.debug(e)\n \n\ndef ack(msgid):\n #logger.debug(msgid)\n #logger.debug(mac)\n #logger.debug(name)\n #logger.debug(value)\n publish(\"v1/devices/me/rpc/response/\" + str(msgid), json.dumps({\"msg\": {\"time\": time.time()}, \"metadata\": \"\", \"msgType\": \"\"}), 1,cloud_name=\"ThingsBoard\")\n\ndef getMode():\n try:\n data = recall()\n for controller in data:\n for measure in controller[\"measures\"]:\n if measure[\"name\"] == \"pidcontrolmode\":\n return measure[\"value\"]\n except:\n return None\n\ndef convert_int(plc_tag, value):\n well_status_codes = {\n 0: \"Running\",\n 1: \"Pumped Off\",\n 2: \"Alarmed\",\n 3: \"Locked Out\",\n 4: \"Stopped\"\n }\n\n pid_control_codes = {\n 0: \"Flow\",\n 1: \"Fluid Level\",\n 2: \"Tubing Pressure\",\n 3: \"Manual\"\n }\n\n downhole_codes = {\n 0: \"OK\",\n 1: \"Connecting\",\n 2: \"Open Circuit\",\n 3: \"Shorted\",\n 4: \"Cannot Decode\"\n }\n\n permissive_codes = {\n 0: \"OK\",\n 1: \"Flow\",\n 2: \"Intake Pressure\",\n 3: \"Intake Temperature\",\n 4: \"Tubing Pressure\",\n 5: \"VFD\",\n 6: \"Fluid Level\",\n 7: \"Min. Downtime\"\n }\n\n alarm_codes = {\n 0: \"OK\",\n 1: \"Alarm\"\n }\n\n alarm_vfd_codes = {\n 0: \"OK\",\n 1: \"Locked Out\"\n }\n\n vfd_fault_codes = {\n 0: \"No Fault\",\n 2: \"Auxiliary Input\",\n 3: \"Power Loss\",\n 4: \"UnderVoltage\",\n 5: \"OverVoltage\",\n 7: \"Motor Overload\",\n 8: \"Heatsink OverTemp\",\n 9: \"Thermister OverTemp\",\n 10: \"Dynamic Brake OverTemp\",\n 12: \"Hardware OverCurrent\",\n 13: \"Ground Fault\",\n 14: \"Ground Warning\",\n 15: \"Load Loss\",\n 17: \"Input Phase Loss\",\n 18: \"Motor PTC Trip\",\n 19: \"Task Overrun\",\n 20: \"Torque Prove Speed Band\",\n 21: \"Output Phase Loss\",\n 24: \"Decel Inhibit\",\n 25: \"OverSpeed Limit\",\n 26: \"Brake Slipped\",\n 27: \"Torque Prove Conflict\",\n 28: \"TP Encls Confict\",\n 29: \"Analog In Loss\",\n 33: \"Auto Restarts Exhausted\",\n 35: \"IPM OverCurrent\",\n 36: \"SW OverCurrent\",\n 38: \"Phase U to Ground\",\n 39: \"Phase V to Ground\",\n 40: \"Phase W to Ground\",\n 41: \"Phase UV Short\",\n 42: \"Phase VW Short\",\n 43: \"Phase WU Short\",\n 44: \"Phase UNeg to Ground\",\n 45: \"Phase VNeg to Ground\",\n 46: \"Phase WNeg to Ground\",\n 48: \"System Defaulted\",\n 49: \"Drive Powerup\",\n 51: \"Clear Fault Queue\",\n 55: \"Control Board Overtemp\",\n 59: \"Invalid Code\",\n 61: \"Shear Pin 1\",\n 62: \"Shear Pin 2\",\n 64: \"Drive Overload\",\n 66: \"OW Torque Level\",\n 67: \"Pump Off\",\n 71: \"Port 1 Adapter\",\n 72: \"Port 2 Adapter\",\n 73: \"Port 3 Adapter\",\n 74: \"Port 4 Adapter\",\n 75: \"Port 5 Adapter\",\n 76: \"Port 6 Adapter\",\n 77: \"IR Volts Range\",\n 78: \"FluxAmps Ref Range\",\n 79: \"Excessive Load\",\n 80: \"AutoTune Aborted\",\n 81: \"Port 1 DPI Loss\",\n 82: \"Port 2 DPI Loss\",\n 83: \"Port 3 DPI Loss\",\n 84: \"Port 4 DPI Loss\",\n 85: \"Port 5 DPI Loss\",\n 86: \"Port 6 DPI Loss\",\n 87: \"IXo Voltage Range\",\n 91: \"Primary Velocity Feedback Loss\",\n 93: \"Hardware Enable Check\",\n 94: \"Alternate Velocity Feedback Loss\",\n 95: \"Auxiliary Velocity Feedback Loss\",\n 96: \"Position Feedback Loss\",\n 97: \"Auto Tach Switch\",\n 100: \"Parameter Checksum\",\n 101: \"Power Down NVS Blank\",\n 102: \"NVS Not Blank\",\n 103: \"Power Down NVS Incompatible\",\n 104: \"Power Board Checksum\",\n 106: \"Incompat MCB-PB\",\n 107: \"Replaced MCB-PB\",\n 108: \"Analog Calibration Checksum\",\n 110: \"Invalid Power Board Data\",\n 111: \"Power Board Invalid ID\",\n 112: \"Power Board App Min Version\",\n 113: \"Tracking DataError\",\n 115: \"Power Down Table Full\",\n 116: \"Power Down Entry Too Large\",\n 117: \"Power Down Data Checksum\",\n 118: \"Power Board Power Down Checksum\",\n 124: \"App ID Changed\",\n 125: \"Using Backup App\",\n 134: \"Start on Power Up\",\n 137: \"External Precharge Error\",\n 138: \"Precharge Open\",\n 141: \"Autotune Enc Angle\",\n 142: \"Autotune Speed Restricted\",\n 143: \"Autotune Current Regulator\",\n 144: \"Autotune Inertia\",\n 145: \"Autotune Travel\",\n 13035: \"Net IO Timeout\",\n 13037: \"Net IO Timeout\"\n\n }\n\n plc_tags = {\n \"wellstatus\": well_status_codes.get(value, \"Invalid Code\"),\n \"pidcontrolmode\": pid_control_codes.get(value, \"Invalid Code\"),\n \"downholesensorstatus\": downhole_codes.get(value, \"Invalid Code\"),\n \"alarmflowrate\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmintakepressure\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmintaketemperature\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmtubingpressure\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmvfd\": alarm_codes.get(value, \"Invalid Code\"),\n \"alarmlockout\": alarm_vfd_codes.get(value, \"Invalid Code\"),\n \"alarmfluidlevel\": alarm_codes.get(value, \"Invalid Code\"),\n \"runpermissive\": permissive_codes.get(value, \"Invalid Code\"),\n \"startpermissive\": permissive_codes.get(value, \"Invalid Code\"),\n \"last_vfd_fault_code\": vfd_fault_codes.get(value, \"Invalid Code\"),\n \"vfd_fault\": vfd_fault_codes.get(value, \"Invalid Code\"),\n \"flowmeter_fault\": alarm_codes.get(value, \"Invalid Code\")\n }\n\n return plc_tags.get(plc_tag, \"Invalid Tag\")\n", + "msgType": 0, + "cloudName": "ThingsBoard", + "trigger": "command_event" + } + ] + }, + "labels": [ + { + "key": "SN", + "value": "GF5022403048023", + "_id": "000066cf56dda1a2" + }, + { + "key": "MAC", + "value": "ec:6e:79:02:4f:c6", + "_id": "000166cf56dd0ec0" + }, + { + "_id": "000266cf56f026bd", + "key": "MAC_UPPER", + "value": "C4:93:00:0D:E0:EF" + }, + { + "_id": "000366cf56fe955d", + "key": "MAC_LOWER", + "value": "c4:93:00:0d:e0:ef" + } + ], + "modbusSlave": { + "enable": 0, + "protocol": "Modbus-TCP", + "port": 502, + "slaveAddr": 1, + "int16Ord": "ab", + "int32Ord": "abcd", + "float32Ord": "abcd", + "maxConnection": 5, + "useRawvalue": 1, + "mapping_table": [] + }, + "modbusRTUSlave": { + "enable": 0, + "protocol": "Modbus-RTU", + "coms": "rs485", + "slaveAddr": 1, + "int16Ord": "ab", + "int32Ord": "abcd", + "float32Ord": "abcd", + "mapping_table": [] + }, + "iec104Server": { + "enable": 0, + "cotSize": 2, + "port": 2404, + "serverList": [ + { + "asduAddr": 1 + } + ], + "kValue": 12, + "wValue": 8, + "t0": 15, + "t1": 15, + "t2": 10, + "t3": 20, + "maximumLink": 5, + "timeSet": 1, + "byteOrder": "abcd", + "useRawvalue": 1, + "asduLen": 2, + "mapping_table": [] + }, + "iec101Server": { + "enable": 0, + "coms": "rs485", + "mode": "UnBalance", + "protocolMode": 0, + "linkLen": 2, + "linkAddr": 1, + "asduLen": 2, + "ioaLen": 3, + "cotLen": 2, + "serverList": [ + { + "asduAddr": 1 + } + ], + "linkTimeOut": 2000, + "timeSet": 1, + "idleTimeOut": 10000, + "byteOrder": "abcd", + "useRawvalue": 1, + "mappingTable": { + "YX": [], + "YC": [], + "YK": [] + } + }, + "iec104Client": { + "enable": 0, + "connectType": 2, + "serverAddr": "ipower.inhandcloud.cn", + "serverPort": 2406, + "communicationCode": "", + "protocol": 1, + "asduAddr": 1, + "tls": 1, + "verification": 1, + "mapping_table": { + "YX": [], + "YC": [], + "YK": [] + } + }, + "opcuaServer": { + "enable": 0, + "port": 4840, + "maximumLink": 5, + "securityMode": 0, + "identifierType": "String", + "certificate": "None", + "privateKey": "None", + "pubsub": 0, + "useRawvalue": 1, + "mapping_table": [] + }, + "sl651Slave": { + "enable": 0, + "centerAaddr": 1, + "remoteAddr": "", + "addrCode": "", + "password": "", + "platform_list": [], + "useRawvalue": 1, + "mapping_table": [] + }, + "hj212Client": { + "enable": 0, + "useRawvalue": 1, + "platform_list": [], + "block_list": [], + "mapping_table": [] + }, + "bacnetServer": { + "enable": 0, + "protocol": "BACnet/IP", + "deviceId": 0, + "port": 47808, + "bbmdEnable": 0, + "useRawvalue": 1, + "mapping_table": [] + }, + "Dnp3Server": { + "enable": 0, + "protocol": "Dnp3-TCP", + "slaveAddr": 1, + "masterAddr": 2, + "port": 20000, + "useRawvalue": 1, + "enableUnsol": 0, + "maxFrasize": 4096, + "layerTimeout": 1000, + "linkRetry": 5, + "enableLink": 0, + "mapping_table": [] + }, + "southMetadata": {}, + "bindMetadata": { + "version": "", + "timestamp": "" + }, + "bindConfig": { + "enable": 0, + "bind": { + "modelId": "", + "modelName": "", + "srcId": "", + "srcName": "", + "devId": "", + "devName": "" + }, + "varGroups": [], + "variables": [], + "alerts": [] + }, + "templates": {}, + "version": "3.0.1" +} \ No newline at end of file diff --git a/Pub_Sub/rigpump/.DS_Store b/Pub_Sub/rigpump/.DS_Store index 43a933a..07f8b33 100644 Binary files a/Pub_Sub/rigpump/.DS_Store and b/Pub_Sub/rigpump/.DS_Store differ diff --git a/Pub_Sub/rigpump/thingsboard/pub/sendData.py b/Pub_Sub/rigpump/thingsboard/pub/sendData.py index 8f83ed3..2b3942a 100644 --- a/Pub_Sub/rigpump/thingsboard/pub/sendData.py +++ b/Pub_Sub/rigpump/thingsboard/pub/sendData.py @@ -47,8 +47,6 @@ def chunk_payload(payload, chunk_size=20): def sendData(message): #logger.debug(message) - - payload = {"ts": (round(dt.timestamp(dt.now())/600)*600)*1000, "values": {}} attributes_payload = {} for measure in message["measures"]: diff --git a/Pub_Sub/transferlite/thingsboard/pub/sendData.py b/Pub_Sub/transferlite/thingsboard/pub/sendData.py new file mode 100644 index 0000000..a51cc07 --- /dev/null +++ b/Pub_Sub/transferlite/thingsboard/pub/sendData.py @@ -0,0 +1,89 @@ +# Enter your python code. +import json, time +from datetime import datetime as dt +from common.Logger import logger +from quickfaas.remotebus import publish + +report_period = 600 + +def chunk_payload(payload, chunk_size=20): + if "values" in payload: + # Original format: {"ts": ..., "values": {...}} + chunked_values = list(payload["values"].items()) + for i in range(0, len(chunked_values), chunk_size): + yield { + "ts": payload["ts"], + "values": dict(chunked_values[i:i+chunk_size]) + } + else: + # New format: {"key1": "value1", "key2": "value2"} + chunked_keys = list(payload.keys()) + for i in range(0, len(chunked_keys), chunk_size): + yield {k: payload[k] for k in chunked_keys[i:i+chunk_size]} + +def sendData(message): + #logger.debug(message) + payload = {"ts": (round(dt.timestamp(dt.now())/report_period)*report_period)*1000, "values": {}} + attributes_payload = {} + for measure in message["measures"]: + try: + logger.debug(measure) + if measure["health"] == 1: + if measure["name"] in ["auto_manual", "system1_hasleveltransmitter", "system2_hasleveltransmitter", "state_supervisor", "state_system1", "state_system2"]: + logger.debug("Converting DINT/BOOL to STRING") + payload["values"][measure["name"]] = convert_int(measure["name"], measure["value"]) + payload["values"][measure["name"] + "_int"] = measure["value"] + else: + payload["values"][measure["name"]] = measure["value"] + except Exception as e: + logger.error(e) + + for chunk in chunk_payload(payload=payload): + publish(__topic__, json.dumps(chunk), __qos__, cloud_name="ThingsBoard") + time.sleep(2) + + attributes_payload["latestReportTime"] = (round(dt.timestamp(dt.now())/report_period)*report_period)*1000 + for chunk in chunk_payload(payload=attributes_payload): + publish("v1/devices/me/attributes", json.dumps(chunk), __qos__, cloud_name="ThingsBoard") + time.sleep(2) + +def convert_int(plc_tag, value): + + + TRUE_FALSE = { + 0: "false", + 1: "true" + } + + AUTO_MANUAL = { + 0: "Auto", + 1: "Manual" + } + + PHASE_STATES = { + 1: "Running", + 2: "Holding", + 4: "Restarting", + 8: "Stopping", + 16: "Aborting", + 32: "Resetting", + 64: "Idle", + 128: "Held", + 256: "Complete", + 512: "Stopped", + 1024: "Aborted" + } + + + plc_tags = { + "auto_manual": AUTO_MANUAL.get(value, "Invalid Code"), + "system1_hasleveltransmitter": TRUE_FALSE.get(value, "Invalid Code"), + "system2_hasleveltransmitter": TRUE_FALSE.get(value, "Invalid Code"), + "state_supervisor": PHASE_STATES.get(value, "Invalid Code"), + "state_system1": PHASE_STATES.get(value, "Invalid Code"), + "state_system2": PHASE_STATES.get(value, "Invalid Code") + } + + return plc_tags.get(plc_tag, "Invalid Tag") + + \ No newline at end of file diff --git a/Pub_Sub/transferlite/thingsboard/sub/receiveCommand.py b/Pub_Sub/transferlite/thingsboard/sub/receiveCommand.py new file mode 100644 index 0000000..6426646 --- /dev/null +++ b/Pub_Sub/transferlite/thingsboard/sub/receiveCommand.py @@ -0,0 +1,135 @@ +import json, time, os +from datetime import datetime as dt +from quickfaas.measure import recall, write +from quickfaas.remotebus import publish +from common.Logger import logger + +# Helper function to split the payload into chunks +def chunk_payload(payload, chunk_size=20): + chunked_values = list(payload["values"].items()) + for i in range(0, len(chunked_values), chunk_size): + yield { + "ts": payload["ts"], + "values": dict(chunked_values[i:i+chunk_size]) + } + +def sync(): + #get new values and send + payload = {"ts": round(dt.timestamp(dt.now()))*1000, "values": {}} + topic = "v1/devices/me/telemetry" + try: + data = recall()#json.loads(recall().decode("utf-8")) + except Exception as e: + logger.error(e) + logger.debug(data) + for controller in data: + for measure in controller["measures"]: + #publish measure + if measure["name"] in ["auto_manual", "system1_hasleveltransmitter", "system2_hasleveltransmitter", "state_supervisor", "state_system1", "state_system2"]: + payload["values"][measure["name"]] = convert_int(measure["name"], measure["value"]) + payload["values"][measure["name"]+ "_int"] = measure["value"] + else: + payload["values"][measure["name"]] = measure["value"] + logger.debug("Sending on topic: {}".format(topic)) + logger.debug("Sending value: {}".format(payload)) + for chunk in chunk_payload(payload=payload): + publish(topic, json.dumps(chunk), 1, cloud_name="ThingsBoard") + time.sleep(2) + +def writeplctag(value): + #value in the form {"measurement": , "value": } + try: + #value = json.loads(value.replace("'",'"')) + logger.debug(value) + #payload format: [{"name": "advvfdipp", "measures": [{"name": "manualfrequencysetpoint", "value": 49}]}] + message = [{"name": "transferlite", "measures":[{"name":value["measurement"], "value": value["value"]}]}] + resp = write(message) + logger.debug("RETURN FROM WRITE: {}".format(resp)) + return True + except Exception as e: + logger.debug(e) + return False + +def reboot(): + #basic = Basic() + logger.info("!" * 10 + "REBOOTING DEVICE FROM CLOUD" + "!"*10) + r = os.popen("kill -s SIGHUP `cat /var/run/python/supervisord.pid`").read() + logger.info(f"REBOOT : {r}") + +def receiveCommand(topic, payload): + try: + logger.debug(topic) + logger.debug(json.loads(payload)) + p = json.loads(payload) + command = p["method"] + commands = { + "sync": sync, + "writeplctag": writeplctag, + "reboot": reboot + } + if command == "setPLCTag": + try: + result = commands["writeplctag"](p["params"]) + logger.debug(result) + except Exception as e: + logger.error(e) + elif command == "reboot": + try: + ack(topic.split("/")[-1]) + commands["reboot"]() + except Exception as e: + logger.error(e) + #logger.debug(command) + ack(topic.split("/")[-1]) + time.sleep(2) + sync() + except Exception as e: + logger.debug(e) + +def ack(msgid): + #logger.debug(msgid) + #logger.debug(mac) + #logger.debug(name) + #logger.debug(value) + publish("v1/devices/me/rpc/response/" + str(msgid), json.dumps({"msg": {"time": time.time()}, "metadata": "", "msgType": ""}), 1) + +def convert_int(plc_tag, value): + + + TRUE_FALSE = { + 0: "false", + 1: "true" + } + + AUTO_MANUAL = { + 0: "Auto", + 1: "Manual" + } + + PHASE_STATES = { + 1: "Running", + 2: "Holding", + 4: "Restarting", + 8: "Stopping", + 16: "Aborting", + 32: "Resetting", + 64: "Idle", + 128: "Held", + 256: "Complete", + 512: "Stopped", + 1024: "Aborted" + } + + + plc_tags = { + "auto_manual": AUTO_MANUAL.get(value, "Invalid Code"), + "system1_hasleveltransmitter": TRUE_FALSE.get(value, "Invalid Code"), + "system2_hasleveltransmitter": TRUE_FALSE.get(value, "Invalid Code"), + "state_supervisor": PHASE_STATES.get(value, "Invalid Code"), + "state_system1": PHASE_STATES.get(value, "Invalid Code"), + "state_system2": PHASE_STATES.get(value, "Invalid Code") + } + + return plc_tags.get(plc_tag, "Invalid Tag") + + \ No newline at end of file diff --git a/device.csv b/device.csv new file mode 100644 index 0000000..64e7152 --- /dev/null +++ b/device.csv @@ -0,0 +1,6 @@ +name,type,mqttClientId,mqttUsername,mqttPassword +Flow Meter 18,flowmeterskid,cp-flow-meter-18,conocophillipsmqtt,conocophillipsmqtt@1903 +Flow Meter 19,flowmeterskid,cp-flow-meter-19,conocophillipsmqtt,conocophillipsmqtt@1903 +Flow Meter 20,flowmeterskid,cp-flow-meter-20,conocophillipsmqtt,conocophillipsmqtt@1903 +Flow Meter 21,flowmeterskid,cp-flow-meter-21,conocophillipsmqtt,conocophillipsmqtt@1903 +Flow Meter 22,flowmeterskid,cp-flow-meter-22,conocophillipsmqtt,conocophillipsmqtt@1903 \ No newline at end of file diff --git a/devices.csv b/devices.csv new file mode 100644 index 0000000..26d069a --- /dev/null +++ b/devices.csv @@ -0,0 +1,6 @@ +name,type,mqtt client id,mqtt user name,mqtt password +Flow Meter 18,flowmeterskid,cp-flow-meter-18,conocophillipsmqtt,conocophillipsmqtt@1903 +Flow Meter 19,flowmeterskid,cp-flow-meter-19,conocophillipsmqtt,conocophillipsmqtt@1903 +Flow Meter 20,flowmeterskid,cp-flow-meter-20,conocophillipsmqtt,conocophillipsmqtt@1903 +Flow Meter 21,flowmeterskid,cp-flow-meter-21,conocophillipsmqtt,conocophillipsmqtt@1903 +Flow Meter 22,flowmeterskid,cp-flow-meter-22,conocophillipsmqtt,conocophillipsmqtt@1903 \ No newline at end of file