Files
DataLogger-Generic/daq_sample/pycomm-master/pycomm/cip/cip_const.py

483 lines
14 KiB
Python
Executable File

# -*- coding: utf-8 -*-
#
# cip_const.py - A set of structures and constants used to implement the Ethernet/IP protocol
#
#
# Copyright (c) 2014 Agostino Ruscito <ruscito@gmail.com>
#
# Permission is hereby granted, free of charge, to any person obtaining a copy
# of this software and associated documentation files (the "Software"), to deal
# in the Software without restriction, including without limitation the rights
# to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
# copies of the Software, and to permit persons to whom the Software is
# furnished to do so, subject to the following conditions:
#
# The above copyright notice and this permission notice shall be included in all
# copies or substantial portions of the Software.
#
# THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
# IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
# FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
# AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
# LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
# OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
# SOFTWARE.
#
ELEMENT_ID = {
"8-bit": '\x28',
"16-bit": '\x29',
"32-bit": '\x2a'
}
CLASS_ID = {
"8-bit": '\x20',
"16-bit": '\x21',
}
INSTANCE_ID = {
"8-bit": '\x24',
"16-bit": '\x25'
}
ATTRIBUTE_ID = {
"8-bit": '\x30',
"16-bit": '\x31'
}
# Path are combined as:
# CLASS_ID + PATHS
# For example PCCC path is CLASS_ID["8-bit"]+PATH["PCCC"] -> 0x20, 0x67, 0x24, 0x01.
PATH = {
'Connection Manager': '\x06\x24\x01',
'Router': '\x02\x24\x01',
'Backplane Data Type': '\x66\x24\x01',
'PCCC': '\x67\x24\x01',
'DHCP Channel A': '\xa6\x24\x01\x01\x2c\x01',
'DHCP Channel B': '\xa6\x24\x01\x02\x2c\x01'
}
ENCAPSULATION_COMMAND = { # Volume 2: 2-3.2 Command Field UINT 2 byte
"nop": '\x00\x00',
"list_targets": '\x01\x00',
"list_services": '\x04\x00',
"list_identity": '\x63\x00',
"list_interfaces": '\x64\x00',
"register_session": '\x65\x00',
"unregister_session": '\x66\x00',
"send_rr_data": '\x6F\x00',
"send_unit_data": '\x70\x00'
}
"""
When a tag is created, an instance of the Symbol Object (Class ID 0x6B) is created
inside the controller.
When a UDT is created, an instance of the Template object (Class ID 0x6C) is
created to hold information about the structure makeup.
"""
CLASS_CODE = {
"Message Router": '\x02', # Volume 1: 5-1
"Symbol Object": '\x6b',
"Template Object": '\x6c',
"Connection Manager": '\x06' # Volume 1: 3-5
}
CONNECTION_MANAGER_INSTANCE = {
'Open Request': '\x01',
'Open Format Rejected': '\x02',
'Open Resource Rejected': '\x03',
'Open Other Rejected': '\x04',
'Close Request': '\x05',
'Close Format Request': '\x06',
'Close Other Request': '\x07',
'Connection Timeout': '\x08'
}
TAG_SERVICES_REQUEST = {
"Read Tag": 0x4c,
"Read Tag Fragmented": 0x52,
"Write Tag": 0x4d,
"Write Tag Fragmented": 0x53,
"Read Modify Write Tag": 0x4e,
"Multiple Service Packet": 0x0a,
"Get Instance Attributes List": 0x55,
"Get Attributes": 0x03,
"Read Template": 0x4c,
}
TAG_SERVICES_REPLY = {
0xcc: "Read Tag",
0xd2: "Read Tag Fragmented",
0xcd: "Write Tag",
0xd3: "Write Tag Fragmented",
0xce: "Read Modify Write Tag",
0x8a: "Multiple Service Packet",
0xd5: "Get Instance Attributes List",
0x83: "Get Attributes",
0xcc: "Read Template"
}
I_TAG_SERVICES_REPLY = {
"Read Tag": 0xcc,
"Read Tag Fragmented": 0xd2,
"Write Tag": 0xcd,
"Write Tag Fragmented": 0xd3,
"Read Modify Write Tag": 0xce,
"Multiple Service Packet": 0x8a,
"Get Instance Attributes List": 0xd5,
"Get Attributes": 0x83,
"Read Template": 0xcc
}
"""
EtherNet/IP Encapsulation Error Codes
Standard CIP Encapsulation Error returned in the cip message header
"""
STATUS = {
0x0000: "Success",
0x0001: "The sender issued an invalid or unsupported encapsulation command",
0x0002: "Insufficient memory",
0x0003: "Poorly formed or incorrect data in the data portion",
0x0064: "An originator used an invalid session handle when sending an encapsulation message to the target",
0x0065: "The target received a message of invalid length",
0x0069: "Unsupported Protocol Version"
}
"""
MSG Error Codes:
The following error codes have been taken from:
Rockwell Automation Publication
1756-RM003P-EN-P - December 2014
"""
SERVICE_STATUS = {
0x01: "Connection failure (see extended status)",
0x02: "Insufficient resource",
0x03: "Invalid value",
0x04: "IOI syntax error. A syntax error was detected decoding the Request Path (see extended status)",
0x05: "Destination unknown, class unsupported, instance \nundefined or structure element undefined (see extended status)",
0x06: "Insufficient Packet Space",
0x07: "Connection lost",
0x08: "Service not supported",
0x09: "Error in data segment or invalid attribute value",
0x0A: "Attribute list error",
0x0B: "State already exist",
0x0C: "Object state conflict",
0x0D: "Object already exist",
0x0E: "Attribute not settable",
0x0F: "Permission denied",
0x10: "Device state conflict",
0x11: "Reply data too large",
0x12: "Fragmentation of a primitive value",
0x13: "Insufficient command data",
0x14: "Attribute not supported",
0x15: "Too much data",
0x1A: "Bridge request too large",
0x1B: "Bridge response too large",
0x1C: "Attribute list shortage",
0x1D: "Invalid attribute list",
0x1E: "Request service error",
0x1F: "Connection related failure (see extended status)",
0x22: "Invalid reply received",
0x25: "Key segment error",
0x26: "Invalid IOI error",
0x27: "Unexpected attribute in list",
0x28: "DeviceNet error - invalid member ID",
0x29: "DeviceNet error - member not settable",
0xD1: "Module not in run state",
0xFB: "Message port not supported",
0xFC: "Message unsupported data type",
0xFD: "Message uninitialized",
0xFE: "Message timeout",
0xff: "General Error (see extended status)"
}
EXTEND_CODES = {
0x01: {
0x0100: "Connection in use",
0x0103: "Transport not supported",
0x0106: "Ownership conflict",
0x0107: "Connection not found",
0x0108: "Invalid connection type",
0x0109: "Invalid connection size",
0x0110: "Module not configured",
0x0111: "EPR not supported",
0x0114: "Wrong module",
0x0115: "Wrong device type",
0x0116: "Wrong revision",
0x0118: "Invalid configuration format",
0x011A: "Application out of connections",
0x0203: "Connection timeout",
0x0204: "Unconnected message timeout",
0x0205: "Unconnected send parameter error",
0x0206: "Message too large",
0x0301: "No buffer memory",
0x0302: "Bandwidth not available",
0x0303: "No screeners available",
0x0305: "Signature match",
0x0311: "Port not available",
0x0312: "Link address not available",
0x0315: "Invalid segment type",
0x0317: "Connection not scheduled"
},
0x04: {
0x0000: "Extended status out of memory",
0x0001: "Extended status out of instances"
},
0x05: {
0x0000: "Extended status out of memory",
0x0001: "Extended status out of instances"
},
0x1F: {
0x0203: "Connection timeout"
},
0xff: {
0x7: "Wrong data type",
0x2001: "Excessive IOI",
0x2002: "Bad parameter value",
0x2018: "Semaphore reject",
0x201B: "Size too small",
0x201C: "Invalid size",
0x2100: "Privilege failure",
0x2101: "Invalid keyswitch position",
0x2102: "Password invalid",
0x2103: "No password issued",
0x2104: "Address out of range",
0x2105: "Address and how many out of range",
0x2106: "Data in use",
0x2107: "Type is invalid or not supported",
0x2108: "Controller in upload or download mode",
0x2109: "Attempt to change number of array dimensions",
0x210A: "Invalid symbol name",
0x210B: "Symbol does not exist",
0x210E: "Search failed",
0x210F: "Task cannot start",
0x2110: "Unable to write",
0x2111: "Unable to read",
0x2112: "Shared routine not editable",
0x2113: "Controller in faulted mode",
0x2114: "Run mode inhibited"
}
}
DATA_ITEM = {
'Connected': '\xb1\x00',
'Unconnected': '\xb2\x00'
}
ADDRESS_ITEM = {
'Connection Based': '\xa1\x00',
'Null': '\x00\x00',
'UCMM': '\x00\x00'
}
UCMM = {
'Interface Handle': 0,
'Item Count': 2,
'Address Type ID': 0,
'Address Length': 0,
'Data Type ID': 0x00b2
}
CONNECTION_SIZE = {
'Backplane': '\x03', # CLX
'Direct Network': '\x02'
}
HEADER_SIZE = 24
EXTENDED_SYMBOL = '\x91'
BOOL_ONE = 0xff
REQUEST_SERVICE = 0
REQUEST_PATH_SIZE = 1
REQUEST_PATH = 2
SUCCESS = 0
INSUFFICIENT_PACKETS = 6
OFFSET_MESSAGE_REQUEST = 40
FORWARD_CLOSE = '\x4e'
UNCONNECTED_SEND = '\x52'
FORWARD_OPEN = '\x54'
LARGE_FORWARD_OPEN = '\x5b'
GET_CONNECTION_DATA = '\x56'
SEARCH_CONNECTION_DATA = '\x57'
GET_CONNECTION_OWNER = '\x5a'
MR_SERVICE_SIZE = 2
PADDING_BYTE = '\x00'
PRIORITY = '\x0a'
TIMEOUT_TICKS = '\x05'
TIMEOUT_MULTIPLIER = '\x01'
TRANSPORT_CLASS = '\xa3'
CONNECTION_PARAMETER = {
'PLC5': 0x4302,
'SLC500': 0x4302,
'CNET': 0x4320,
'DHP': 0x4302,
'Default': 0x43f8,
}
"""
Atomic Data Type:
Bit = Bool
Bit array = DWORD (32-bit boolean aray)
8-bit integer = SINT
16-bit integer = UINT
32-bit integer = DINT
32-bit float = REAL
64-bit integer = LINT
From Rockwell Automation Publication 1756-PM020C-EN-P November 2012:
When reading a BOOL tag, the values returned for 0 and 1 are 0 and 0xff, respectively.
"""
S_DATA_TYPE = {
'BOOL': 0xc1,
'SINT': 0xc2, # Signed 8-bit integer
'INT': 0xc3, # Signed 16-bit integer
'DINT': 0xc4, # Signed 32-bit integer
'LINT': 0xc5, # Signed 64-bit integer
'USINT': 0xc6, # Unsigned 8-bit integer
'UINT': 0xc7, # Unsigned 16-bit integer
'UDINT': 0xc8, # Unsigned 32-bit integer
'ULINT': 0xc9, # Unsigned 64-bit integer
'REAL': 0xca, # 32-bit floating point
'LREAL': 0xcb, # 64-bit floating point
'STIME': 0xcc, # Synchronous time
'DATE': 0xcd,
'TIME_OF_DAY': 0xce,
'DATE_AND_TIME': 0xcf,
'STRING': 0xd0, # character string (1 byte per character)
'BYTE': 0xd1, # byte string 8-bits
'WORD': 0xd2, # byte string 16-bits
'DWORD': 0xd3, # byte string 32-bits
'LWORD': 0xd4, # byte string 64-bits
'STRING2': 0xd5, # character string (2 byte per character)
'FTIME': 0xd6, # Duration high resolution
'LTIME': 0xd7, # Duration long
'ITIME': 0xd8, # Duration short
'STRINGN': 0xd9, # character string (n byte per character)
'SHORT_STRING': 0xda, # character string (1 byte per character, 1 byte length indicator)
'TIME': 0xdb, # Duration in milliseconds
'EPATH': 0xdc, # CIP Path segment
'ENGUNIT': 0xdd, # Engineering Units
'STRINGI': 0xde # International character string
}
I_DATA_TYPE = {
0xc1: 'BOOL',
0xc2: 'SINT', # Signed 8-bit integer
0xc3: 'INT', # Signed 16-bit integer
0xc4: 'DINT', # Signed 32-bit integer
0xc5: 'LINT', # Signed 64-bit integer
0xc6: 'USINT', # Unsigned 8-bit integer
0xc7: 'UINT', # Unsigned 16-bit integer
0xc8: 'UDINT', # Unsigned 32-bit integer
0xc9: 'ULINT', # Unsigned 64-bit integer
0xca: 'REAL', # 32-bit floating point
0xcb: 'LREAL', # 64-bit floating point
0xcc: 'STIME', # Synchronous time
0xcd: 'DATE',
0xce: 'TIME_OF_DAY',
0xcf: 'DATE_AND_TIME',
0xd0: 'STRING', # character string (1 byte per character)
0xd1: 'BYTE', # byte string 8-bits
0xd2: 'WORD', # byte string 16-bits
0xd3: 'DWORD', # byte string 32-bits
0xd4: 'LWORD', # byte string 64-bits
0xd5: 'STRING2', # character string (2 byte per character)
0xd6: 'FTIME', # Duration high resolution
0xd7: 'LTIME', # Duration long
0xd8: 'ITIME', # Duration short
0xd9: 'STRINGN', # character string (n byte per character)
0xda: 'SHORT_STRING', # character string (1 byte per character, 1 byte length indicator)
0xdb: 'TIME', # Duration in milliseconds
0xdc: 'EPATH', # CIP Path segment
0xdd: 'ENGUNIT', # Engineering Units
0xde: 'STRINGI' # International character string
}
REPLAY_INFO = {
0x4e: 'FORWARD_CLOSE (4E,00)',
0x52: 'UNCONNECTED_SEND (52,00)',
0x54: 'FORWARD_OPEN (54,00)',
0x6f: 'send_rr_data (6F,00)',
0x70: 'send_unit_data (70,00)',
0x00: 'nop',
0x01: 'list_targets',
0x04: 'list_services',
0x63: 'list_identity',
0x64: 'list_interfaces',
0x65: 'register_session',
0x66: 'unregister_session',
}
PCCC_DATA_TYPE = {
'N': '\x89',
'B': '\x85',
'T': '\x86',
'C': '\x87',
'S': '\x84',
'F': '\x8a',
'ST': '\x8d',
'A': '\x8e',
'R': '\x88',
'O': '\x8b',
'I': '\x8c'
}
PCCC_DATA_SIZE = {
'N': 2,
# 'L': 4,
'B': 2,
'T': 6,
'C': 6,
'S': 2,
'F': 4,
'ST': 84,
'A': 2,
'R': 6,
'O': 2,
'I': 2
}
PCCC_CT = {
'PRE': 1,
'ACC': 2,
'EN': 15,
'TT': 14,
'DN': 13,
'CU': 15,
'CD': 14,
'OV': 12,
'UN': 11,
'UA': 10
}
PCCC_ERROR_CODE = {
-2: "Not Acknowledged (NAK)",
-3: "No Reponse, Check COM Settings",
-4: "Unknown Message from DataLink Layer",
-5: "Invalid Address",
-6: "Could Not Open Com Port",
-7: "No data specified to data link layer",
-8: "No data returned from PLC",
-20: "No Data Returned",
16: "Illegal Command or Format, Address may not exist or not enough elements in data file",
32: "PLC Has a Problem and Will Not Communicate",
48: "Remote Node Host is Missing, Disconnected, or Shut Down",
64: "Host Could Not Complete Function Due To Hardware Fault",
80: "Addressing problem or Memory Protect Rungs",
96: "Function not allows due to command protection selection",
112: "Processor is in Program mode",
128: "Compatibility mode file missing or communication zone problem",
144: "Remote node cannot buffer command",
240: "Error code in EXT STS Byte"
}